Product Information

2730760

2730760 electronic component of Amprobe

Datasheet
Clamp Multimeters & Accessories 1000A POWER QUALITY CLAMP-ON W/THD-F

Manufacturer: Amprobe
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 536.8191 ea
Line Total: USD 536.82

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 10 May to Thu. 16 May

MOQ : 1
Multiples : 1

Stock Image

2730760
Amprobe

1 : USD 536.8191
3 : USD 489.5818
5 : USD 463.8173

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Brand
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
3026830 electronic component of Amprobe 3026830

Test Accessories - Other DELUXE CASE HARD SHELL
Stock : 0

3311961 electronic component of Amprobe 3311961

Environmental Test Equipment TACHOMETER HANDHELD CONACT/NON-CONTACT
Stock : 1

LM-100 electronic component of Amprobe LM-100

Environmental Test Equipment LIGHT METER MANUAL RANGING
Stock : 1

MLS55-3 electronic component of Amprobe MLS55-3

Test Accessories - Other PIPE TRANSMITTER FOR AT-3500
Stock : 1

3435099 electronic component of Amprobe 3435099

Fluke PIPE TRANSMITTER FOR AT-3500
Stock : 0

AM-4B electronic component of Amprobe AM-4B

AM4B amprobe
Stock : 0

A-47L electronic component of Amprobe A-47L

Energizer for Multimeter
Stock : 1

4544583 electronic component of Amprobe 4544583

BR-7000C - Battery Charger AT-7000-T Rechargable Batteries
Stock : 0

CC-7000 electronic component of Amprobe CC-7000

Instrument Protection and Storage Hard Case AT-7000
Stock : 0

4313925 electronic component of Amprobe 4313925

CC-7000 - Carrying Case - AT7000
Stock : 0

Image Description
MA120 electronic component of Teledyne FLIR / Extech MA120

Clamp Multimeters & Accessories Clamp Meter, Mini, AC/DC W/NCV/Flashlight
Stock : 2

499904 electronic component of Wurth 499904

Multi-Function Test Tweezer Tests Fuses, LEDs, PCB Circuit Conductivity, Resistance and Switches
Stock : 20

MINI 09 electronic component of Chauvin Arnoux MINI 09

AC current clamp adapter; Features: double insulated; 180g
Stock : 1

MA443 electronic component of Teledyne FLIR / Extech MA443

Clamp Multimeters & Accessories 400A TRUE RMS AC CLAMP METER + NCV
Stock : 0

UT220 electronic component of Uni-T UT220

AC digital clamp meter; Øcable:60mm; LCD (2000), with a backlit
Stock : 2

KEW105816 electronic component of Kyoritsu KEW105816

AC/DC current clamp adapter; KT2001A
Stock : 1

KEW7146 electronic component of Kyoritsu KEW7146

Adapter for clamps; banana 4mm plug x2
Stock : 4

KEW2031 electronic component of Kyoritsu KEW2031

AC digital clamp meter; Øcable: 24mm; LCD; I AC: 20A,200A; 100g
Stock : 1

P 1615 electronic component of PEAKTECH P 1615

AC/DC digital clamp meter; Øcable: 35mm; I DC: 40A,400A,1kA; 300g
Stock : 1

P 1635 electronic component of PEAKTECH P 1635

AC/DC digital clamp meter; Øcable: 18mm; I DC: 2A,80A; 180g
Stock : 3

ACD-40PQ & ACD-41PQ 1000A Power Quality Clamp-on with THD Measurement CAT TRUE RMS z 600V The ACD-40s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. TRMS sensing Automatic polarity Measurements: Low battery indication -Total Harmonics Distortion THD, AC/DC Peak hold (ADC-41PQ) Voltage up to 600V, AC Current up to Data hold 1000A, Resistance, Frequency, Large, easy to read LCD display -Temperature with backlight ACD-41PQ also measures Active (W), Accommodates conductors up to Reactive (VAR) and Apparent (VA) Power 1.77 (45mm) in diameter with dual-display Power Factor readout Carrying case, test leads, AutoVA - Auto Selection of AC Volts, DC batteries (installed), thermocouple Volts or AC Amps (ACD-41PQ) and manual included Data-logging 5400 points (ACD-40PQ) Voltage overload protection for all Optional PC interface capability functions up to 600V AC/DC Audible continuity Safety CAT III 600V Auto power off FEATURES ACD-40PQ ACD-41PQ BASIC ACCURACY Yes TRMS Measuremaent 40.0 / 400.0 / 1000 A +/-(1.0% Rdg + 5 LSD) 50 and 60Hz AC Current 600.0V +/-(0.5% Rdg + 5 LSD) DC Voltage 600.0V +/-(0.5% Rdg + 5 LSD) 50 / 60 Hz AC Voltage 999.9 Ohms +/-(1.0% Rdg + 6 LSD) Resistance 5.00Hz to 500.0Hz +/-(0.5% Rdg +4 LSD) Frequency 0 to 600.0 kW +/-(2.0% Rdg + 6 LSD) Harmonics Fund to 10th & PF > 0.7 Active Power (W) 0 to 600.0 kVAR +/-(2.0% Rdg + 6 LSD) Harmonics Fund to 10th & PF > 0.7 Reactive Power (VAR) 0 to 600.0 kVA +/-(2.0% Rdg + 6 LSD) Harmonics Fund to 10th Apparent Power (VA) 0.10 to 0.99 +/- 3 LSD Harmonics Fund to 21th Power Factor 0.0% to 99.9% 1.5% of Reading + 6d Fund Frequency THD-R * . 0.0% to 99.9% 1.5% of Reading + 6d Fund Frequency THD-F * -58 F to 572 F +/-(2.0% Rdg + 6F) Temperature (-50 C to 300 C) +/-(2.0 % Rdg + 3C) 5400 Points Hi-Lo Logging *THD-R is defined as: (Total Harmonic RMS / Total RMS) x 100% THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100% www.AMPROBE.com CAT TRUE RMS z 600V The ACD-40s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. OPTIONAL ACCESSORIES PART NUMBER PC Interface kit (PC connection cable with software) RS-232 KIT2 Line splitter (Energizer) A47L 5000A Clamp-on Current Transformer (50 to 1) CT50-1 3000A Clamp-on Current Transformer (50 to 1) CT50-2 Dual input Thermocouple adapter with two ther- DKTA-620 and mocouples -50F to 600F two of TPK-56 Alligator Clips (For test leads) VRC-320 REPLACEMENT PARTS PART NUMBER (supplied with product) Test leads with set of alligator clips MTL-90B (alligator clips are not supplied with product) Thermocouple TPK-59 Carrying case SV-U Instruction Manual www.AMPROBE.com EN61010-2-032(1995), UL3111-2-032(1999). GENERAL SPECIFICATIONS Special features (ACD-41PQ): Backlight display Measurement Category: III 600 Volts ac & dc Display: Voltage functions: 6000 counts LCD AutoVATM (Auto Selection on ACV, DCV or ACA Transient protection: 6.5kV (1.2/50s surge) display(s) functions) Power measurement of selectable W, for all models Power, Ohm & Hz functions: 9999 counts LCD VAR & VA with dual-display Total Power Factor Pollution degree: 2 display(s) features Total harmonic distortion THD%-F E.M.C.: Meets EN61326(1997, 1998/A1), ACA clamp-on function: 4000 counts LCD display(s) PEAK-RMS HOLD EN61000-4-2(1995), and EN61000-4-3(1996) Update Rate: Power function: 1 per second Special features (ACD40PQ): Backlight display In an RF field of 3V/m: nominal (ACD-41PQ only) THD%-R Total harmonic distortion-RMS) On Total Accuracy = Specified Accuracy + 45 digits Voltage, ACA clamp-on, Ohm, Hz & screen stand-alone Hi-Lo logging (5400 minutes) Performance above 3V/m is not specified Temperature functions: 4 per second nominal at sampling speed of faster than: 20 per second Overload Protections: ACD-40PQ Hz function: 2 per second nominal. for Voltage & ACA functions 4 per second for ACA Clamp-on jaws: AC 1000A RMS Polarity: Automatic Ohm & Temperature functions 2 per second for continuous + & COM terminals (all functions): Low Battery: Below approx. 2.4V Hz function 600VDC/VAC RMS Operating Temperature: 0C to 40C ELECTRICAL SPECIFICATIONS Power Supply: standard 1.5V AAA Size (NEDA Relative Humidity: Maximum relative humidity Accuracy is (% reading digits + number of dig- 24A or IEC LR03) battery X 2 80% for temperature up to 31C decreasing its) or otherwise specified, at 23 C 5 C Power Consumption: Voltage, ACA, Hz & Power linearly to 50% relative humidity at 40C & less than 75% R.H. True RMS (all models) functions: 10mA typical (ACD-41PQ) Altitude: Operating below 2000m ACV & ACA clamp-on accuracies are specified Voltage & ACA functions: 3.5mA typical (ACD-40PQ ) Storage Temperature: -20C to 60C, < 80% from 0% to 100% of range or otherwise speci- Ohm & Temperature functions: 4mA typical R.H. (with battery removed) fied. Maximum Crest Factor is as specified APO Timing: Idle for 16 to 17 minutes Temperature Coefficient: nominal 0.15 x below, and with frequency spectrums, besides APO Consumption: 10A typical (specified accuracy)/ C (0oC -18oC or fundamentals, fall within the meter specified AC Dimension: L224mm X W78mm X H40mm 28C -40C), or otherwise specified bandwidth for non-sinusoidal waveforms. Weight: 224 gm approx Sensing: True RMS sensing for all models Fundamentals are specified at 50Hz and 60Hz. Jaw opening & Conductor diameter: 45mm max Safety: Meets IEC61010-2-032 (1994), www.AMPROBE.com

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted