Product Information

MP7217-DA

MP7217-DA electronic component of Amphenol

Datasheet
Air Quality Sensors Miniature Low Power Flammable Gas Sensor

Manufacturer: Amphenol
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 47.1281 ea
Line Total: USD 47.13

24 - Global Stock
Ships to you between
Thu. 30 May to Mon. 03 Jun
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
24 - WHS 1


Ships to you between Thu. 30 May to Mon. 03 Jun

MOQ : 1
Multiples : 1

Stock Image

MP7217-DA
Amphenol

1 : USD 47.1281
10 : USD 45.3127
25 : USD 45.3009
500 : USD 45.289
2500 : USD 45.2771

24 - WHS 2


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

MP7217-DA
Amphenol

1 : USD 51.935

     
Manufacturer
Product Category
Type
Operating Supply Voltage
Maximum Operating Temperature
Minimum Operating Temperature
Current Rating
Package / Case
Brand
Mounting Style
Hts Code
Product Type
Subcategory
Supply Voltage - Max
Supply Voltage - Min
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
000-46650-93RFX electronic component of Amphenol 000-46650-93RFX

RF Connector Accessory - BNC Resistor Terminated Plug 1 Watt 5% 93 Ohms
Stock : 1

000-7925-RFX electronic component of Amphenol 000-7925-RFX

Adapter, Twinax Jack to Twina
Stock : 1

000-49000 electronic component of Amphenol 000-49000

RF Connectors / Coaxial Connectors 4H FLANGE JCK S/CUP
Stock : 1

000-5575 electronic component of Amphenol 000-5575

RF Connectors / Coaxial Connectors BNC FRONT MOUNT REC UG-625/U
Stock : 1

000-78800 electronic component of Amphenol 000-78800

Conn Type N-TNC Adapter PL/F 0Hz to 11GHz ST
Stock : 58

0.5 INCH-G-4V electronic component of Amphenol 0.5 INCH-G-4V

Board Mount Pressure Sensors 0.5" Gauge 4.5-5.5VDC supply
Stock : 0

00111820202 electronic component of Amphenol 00111820202

Terminal Junction Modules MODULE DE MASSE #20
Stock : 0

00610100300 electronic component of Amphenol 00610100300

Terminal Block Tools & Accessories Tool Front Re-Clocking
Stock : 0

00111510202 electronic component of Amphenol 00111510202

Socket Junction Modules MODULE #22 Waterproof
Stock : 1

00326117359 electronic component of Amphenol 00326117359

Junction System Tools & Accessories BRACKET, RIGHT M2-15
Stock : 0

Image Description
MR003-005.1 electronic component of Microbot MR003-005.1

Sensor: humidity sensor; Interface: analog
Stock : 0

GMS10RVS electronic component of Honeywell GMS10RVS

Air Quality Sensors OXYGEN SENSOR 4V 40UA
Stock : 0

MAGNETIC SWITCH electronic component of Seeed Studio MAGNETIC SWITCH

Sensor: magnetic field; switch; 4.75÷5.25VDC; IC: CT10; Grove
Stock : 0

OKY3072-1 electronic component of OKYSTAR OKY3072-1

Sensor: atmospheric; temperature, humidity; digital; 5VDC
Stock : 0

SGX-4OX electronic component of Amphenol SGX-4OX

Air Quality Sensors 4 Series Oxygen sensor 25% 2 yr life
Stock : 22

VQ25B electronic component of Amphenol VQ25B

Air Quality Sensors Poison Resistant 2V, Hydrocarbon
Stock : 3

USEQGCCACH4100 electronic component of Kemet USEQGCCACH4100

Air Quality Sensors Gas Detector Sensor Analog TO-39
Stock : 1

USEQGCCAC8N100 electronic component of Kemet USEQGCCAC8N100

Air Quality Sensors Gas Detector Sensor Analog TO-39
Stock : 0

USEQGSM1N8L100 electronic component of Kemet USEQGSM1N8L100

Air Quality Sensors Gas Detector Sensor Digital SMD Gas NO
Stock : 0

SGX-7H2S-100 electronic component of Amphenol SGX-7H2S-100

Air Quality Sensors 7 Series H2S sensor fixed apps-200ppm
Stock : 0

SGX Europe Sp. z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland MP-7217-DA Datasheet MEMs Catalytic Combustible Gas Sensor (Miniature) This datasheet describes the use of the MP-7217-DA Pellistor. This is commonly used, but not exclusively, in mining applications. It is a low power, intrinsically safe, extremely robust and poison-resistant device in a certified flameproof enclosure. The MP-7217-DA has been designed to provide the basic sensor performance that will enable a suitable instrument to meet the various (Group 1) mining performance standards. The MP-7217-DA sensors, whilst being optimised for its methane response (up to 5% volume in air), will also detect some other flammable gases and vapours. For further information, contact SGX Sensortech. This compensator is made in the same way as a detector device except that instead of incorporating a catalyst in the FEATURES coating layer, the device is treated so that oxidation cannot take place. Low power designed for battery operation Small size (14mm) The two devices are then used in a circuit that detects the High resistance to mechanical shocks difference in their resistances. Since the two devices are generally a different colour, they have different emissivity and Assessed as intrinsically safe hence different slope resistances. Therefore, to obtain the best Low orientation effect temperature performance, it is necessary on occasion to ATEX Certified connect a fixed resistor in parallel with the compensator to correct for its higher slope resistance. IECEx certified TECHNICAL SPECIFICATION Mechanical Dimensions see outline, page 4 Body material PEI Weight 1g OPERATING PRINCIPLE Environmental The silicon pellistor structure consists of a pair of accurately micro machined diaphragms with two embedded planar heater Ambient temperature range meanders coated with a layer incorporating a noble metal for operation / storage: 40 to +60 C catalyst for the detector device and with inert layer for the certified: 40 to +60 C compensator device. Operational pressure range 70 to 130 kPa Humidity range for operation 0 to 95% The meander acts both as an electrical heater and as a and storage (non-condensing) resistance thermometer. The device is mounted on a PCB with Gases Detected Most flammable gases wire bonding and is surrounded by a plastic can with the end and vapours open to the atmosphere. If a flammable gas is present when the device is heated to about 400 500 C, the gas will oxidise and the resultant release of energy will heat the device still further. Electrical This increase in temperature is detected as an increase in DC supply to detectors +2.9 to +3.1V resistance of the meander. The temperature of the meander is Typical power 39 to 47mA also affected by ambient temperature and by variations in (<96mA at power on) thermal conductivity of the air caused by the possible presence Mode of Operation Continuous of inert gases such as carbon dioxide. To compensate for temperature changes not caused by the oxidation of the flammable gas a second, inert device is used. Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of SGX products in accordance with information contained herein. In case of modification of the product, SGX disclaims all liability. SGX Europe sp .z o.o. Poland REGON: 362332227 DS-0165, Issue 7, 14-Jun-2018, Page 1 SGX Europe Sp. Z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland PERFORMANCE NOTES 1. The polarity of the supply voltage may be reversed without Minimum sensitivity 12 mV/% methane harm. The only effect is to reverse the polarity of the output (measured with 1% methane at 3.0 0.1V) signal. Zero offset range in clean air 20 mV 2. Maximum (slowest) response time measured at 3.0 0.1 V using 1% methane in an SGX test manifold. Faster Response Time (T ) 90 < 12 sec response times will be achieved in instruments/detectors (See Note 2) with optimised gas delivery. Maximum gas concentration 5% methane in air 3. Exceeding these limits may degrade the stability of (see note 3) sensitivity or zero offset. The calibration of the sensor Long Term Zero drift < 1.0 mV / month should be checked if it has been exposed, whilst operating, (see note 4) to gas concentrations greater than the Lower Explosive Long Term Sensitivity drift Limit. < 0.6 mV / month (see note 5) 4. Over 90 day period. 5. Measured at 3.0 0.1V using 1% methane, over 90 days period. MAXIMUM RATINGS (Absolute values) Input voltages between pins: IMPORTANT PRECAUTIONS Pins 2 and 3 3.2 V Read the following instructions carefully before using the MP-7217-DA to avoid erroneous readings and to prevent the Pins 1 and 2 1.6 V device from permanent damage. Pins 1 and 3 1.6 V Heater voltages above the specified maximum rating can damage the MEMS Pellistor. Some compounds are known to affect the catalytic reaction OPERATION of coating material used in pellistors. It is recommended that the detector and compensator be run in Exposure to silicones (by far the most common & virulent a Wheatstone bridge circuit. poison), high levels of hydrogen sulfide (and other sulfur containing compounds), phosphates and phosphorous A suitable circuit is shown below. In use, the bridge supply containing substances or lead containing compounds voltage should be stable to within + 0.05 V, or the output in (e.g. tetraethyl lead) will irreversibly poison the sensor. clean air may change in sympathy. Although it is generally High concentrations of flammable gas may also recommended that pellistors should be run with a constant permanently affect the sensor response. voltage supply to the bridge, it is possible to use a constant Lower concentrations of hydrogen sulfide and other current supply provided that the voltage across the bridge in compounds can cause a temporary loss in response. clean air remains within the recommended limits. This is known as inhibition. Halogenated hydrocarbons such as Freons, trichloroethylene, and methyl chloride Recommended circuit diagram are also possible inhibitors. Sensors generally recover most of their original response once they are returned to fresh air. Specific protection may be needed in applications where poisons or inhibitors are continuously present. SGX recommends using ESD protection equipment when handling the sensor. Care should be taken when soldering the device as excessive heat could cause irreparable damage to sensor elements. Please contact SGX Sensortech for any additional information. SGX Sensortech 2018 Document subject to disclaimer on page 1 DS-0165, Issue 7, 14-Jun-2018, Page 2

Tariff Desc

8543.70.00 - Other machines and apparatus Free
13 No Signal processors (graphic equalisers, crossovers etc.)
91 .. Other

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.

9031.80.00 - MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free
AHT
ALDEN
All Sensors
All Sensors Corporation
AMC
Amphenol
Amphenol Matrix
Amphenol SV Microwave
Amphenol / InterCon Systems
Amphenol / Matrix
Amphenol / SSI Technologies
Amphenol / SV Microwave
Amphenol Advanced Sensor/Nova Sensor
Amphenol Advanced Sensor/Telaire
Amphenol Advanced Sensor/Thermometrics
Amphenol Advanced Sensors
Amphenol Aerospace
Amphenol Aerospace Operations
Amphenol Air LB
Amphenol Air LB France
amphenol air lb germany
AMPHENOL ALDEN
Amphenol Alden Products
Amphenol All Sensors
Amphenol All Sensors Corporation
Amphenol Anytek
AMPHENOL AUDIO
Amphenol Audio / Entertainment
Amphenol Backplane Systems
AMPHENOL CABLES ON DEMAND
AMPHENOL CANADA
AMPHENOL CANADA CORP.
Amphenol Casco
AMPHENOL COMMERCIAL
AMPHENOL COMMERCIAL PRODUCTS
Amphenol Communications Solutions
AMPHENOL CONNEX
Amphenol FCI
AMPHENOL FCI NANTONG
AMPHENOL FIBER OPTICS
Amphenol FSI
Amphenol GEC
Amphenol I/O
Amphenol i2s
Amphenol ICC
AMPHENOL ICC (COMMERCIAL PRODUCTS)
AMPHENOL ICC (FCI)
Amphenol ICC / Aorora
Amphenol ICC / FCI
Amphenol Industrial
Amphenol Industrial Operations
Amphenol IO
AMPHENOL LTW
Amphenol MCP
Amphenol Nexus Technologies
Amphenol Oil & Gas Technology
AMPHENOL PCD
Amphenol PCD Shenzhen
Amphenol Piher
AMPHENOL PIHER SENSORS AND CONTROLS
AMPHENOL RF
Amphenol SGX Sensortech
Amphenol SINE Systems
Amphenol Sine Systems Corp
AMPHENOL SINE SYSTEMS INC.
AMPHENOL SINE/TUCHEL
AMPHENOL SOCAPEX
AMPHENOL SOLAR
AMPHENOL SPECTRA
Amphenol Spectra-Strip
AMPHENOL SV MICROWAVE
amphenol taiwan
Amphenol TCS
Amphenol Technical Products
Amphenol Technology
Amphenol Times Microwave Systems
AMPHENOL TUCHEL
Amphenol Wilcoxon
Amphenol/Spectra-Strip
Amphenol-FCI
Amphenol-RF Division
Amphenol-Tuchel Electronics
BERG / FCI
FCI
FCI ELECTRONICS
INDUSTRIAL@AMPHENOL
InterCon Systems / Amphenol
LTW
PHR
PIHER
PIHER INTERNATIONAL
PIHER INTL
PIHER SENSOR CONTROLS
Piher-Amphenol
SGX SENSORTECH CHINA LIMITED
SV Microwave
SV Microwave Inc
THR
Time Microwave
Time Microwave Systems
Times Microwave
Times Microwave Systems

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted