Product Information

PQC250-54

Product Image X-ON

AC/DC Power Supply Single-OUT 54V 250W 22-Pin
Manufacturer: Murata


Price (Ex GST)

From 147.2058

13 - Global Stock
Ships to you between
Fri. 11 Dec to Thu. 17 Dec
MOQ: 1 Multiples:
Pack Size :   1
Availability Price Quantity
70 - Global Stock


Ships to you between Thu. 10 Dec to Mon. 14 Dec
Calender

MOQ : 1
Multiples : 1

Stock Image

PQC250-54
Murata

1 : $ 163.26
25 : $ 160.2
50 : $ 159.588
100 : $ 155.988

Buy
13 - Global Stock


Ships to you between Fri. 11 Dec to Thu. 17 Dec
Calender

MOQ : 1
Multiples : 1

Stock Image

PQC250-54
Murata

1 : $ 159.6375
25 : $ 150.187

Buy
         
Manufacturer
Murata
Product Category
Modular Power Supplies
Category
Modular Power Supplies
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image PRF15AR102RB6RC
PTC Thermistors 1Kohm@25C 32volts 10K Temp = 135 deg C
Stock : 7700
Stock Image PRF15BB102RB6RC
Thermistors - PTC 1Kohm@25C 32volts 10K Temp = 115 deg C
Stock : 8272
Stock Image PRF15BB103RB6RC
Murata Electronics PTC Thermistors 0402 100C 10Kohms Posistor-Overheat
Stock : 3386
Stock Image PQC250-54D
AC/DC Power Supply Single-OUT 54V 250W 22-Pin
Stock : 54
Stock Image PQC-COVER
Switching Power Supplies Optional Cover Kit Assembly
Stock : 102
Stock Image PQC250-54DRT
Switching Power Supplies 54VDC 4.6A 500uF 250W Conv. Cooled
Stock : 50
Stock Image PQU650-24
Switching Power Supplies 24VDC 650W Terminal Block
Stock : 38
Stock Image PQU650-48
Switching Power Supplies 48VDC 650W Terminal Block
Stock : 50
Stock Image PQU650-54
Switching Power Supplies 54VDC 650W Terminal Block
Stock : 15
Image Description
Stock Image PQC250-54D
AC/DC Power Supply Single-OUT 54V 250W 22-Pin
Stock : 54

PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED) Parameter Conditions Typ. Max. Units 1 Transient Response 50% load step, 1A/?sec slew rate and min 0.1A load ? 5 % Settling Time to 1% of Nominal 500 ?sec Turn On Delay After application of input power 3 sec Output Voltage Rise Monotonic 50 msec Compensates for up to 120mV of total lead drop (output and return connections) with 120 mV remote sense connected. Protected against short circuit and reverse connection. Remote Sense 1 Min. 1 second time between consecutive transients. ENVIRONMENTAL CHARACTERISTICS Min. Typ. Max. Parameter Conditions Units Storage Temperature Range -40 85 See power derating curves -10 70 ?C Start up with -20C @ 100VAC minimum input Operating Temperature Range -20 - *contact Murata for lower operating temperature range 10 95 Operating Humidity Non-condensing % 2 -200 5000 Operating Altitude m 2,145K Telcordia SR-332 Issue 3; M1C3 @ 40?C MTBF Hours 4,500K Telcordia SR-332 Issue 3; M1C3 @ 25?C Shock 30G, non-operating Complies Sine Sweep; 5-150Hz, 2G Operational Vibration Complies Random Vibration, 5-500Hz, 1.11G th IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition 3 Safety ? Medical Standards EMC Standard Requirements ) 2 x MOPP (Primary-Secondary) CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition EN60601-1:2006+CORR:2010 IEC/EN/UL/CSA 60950-1 Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1 Consumer Standards CE Marking per LVD 1 IEC62368-1 Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal Weight (typ.) 0.352/0.78 kg/lbs 1 Planned submission, contact Murata for additional details 2 3000 M max. altitude for Medical applications 3 when deployed in End User Systems PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units V1 (main output) latching 115 140 % Over Voltage Protection V2 (aux output) latching 5.5 7.5 V V1, hiccup mode 120 150 Over Current Protection V1, latch mode 160 Short circuit %Amax V2, auto-recovery 110 150 Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C Remote Sense Short Circuit Protection Complies Remote Sense Reverse Connection Protection Complies ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Chassis 1500 Primary to Secondary (2xMOPP) 4000 Isolation VAC Secondary to Chassis 1500 Output to Output 1500 Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A www.murata-ps.com/support PQC250.A13 Page 2 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED) Parameter Conditions Typ. Max. Units 1 Transient Response 50% load step, 1A/?sec slew rate and min 0.1A load ? 5 % Settling Time to 1% of Nominal 500 ?sec Turn On Delay After application of input power 3 sec Output Voltage Rise Monotonic 50 msec Compensates for up to 120mV of total lead drop (output and return connections) with 120 mV remote sense connected. Protected against short circuit and reverse connection. Remote Sense 1 Min. 1 second time between consecutive transients. ENVIRONMENTAL CHARACTERISTICS Min. Typ. Max. Parameter Conditions Units Storage Temperature Range -40 85 See power derating curves -10 70 ?C Start up with -20C @ 100VAC minimum input Operating Temperature Range -20 - *contact Murata for lower operating temperature range 10 95 Operating Humidity Non-condensing % 2 -200 5000 Operating Altitude m 2,145K Telcordia SR-332 Issue 3; M1C3 @ 40?C MTBF Hours 4,500K Telcordia SR-332 Issue 3; M1C3 @ 25?C Shock 30G, non-operating Complies Sine Sweep; 5-150Hz, 2G Operational Vibration Complies Random Vibration, 5-500Hz, 1.11G th IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition 3 Safety ? Medical Standards EMC Standard Requirements ) 2 x MOPP (Primary-Secondary) CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition EN60601-1:2006+CORR:2010 IEC/EN/UL/CSA 60950-1 Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1 Consumer Standards CE Marking per LVD 1 IEC62368-1 Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal Weight (typ.) 0.352/0.78 kg/lbs 1 Planned submission, contact Murata for additional details 2 3000 M max. altitude for Medical applications 3 when deployed in End User Systems PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units V1 (main output) latching 115 140 % Over Voltage Protection V2 (aux output) latching 5.5 7.5 V V1, hiccup mode 120 150 Over Current Protection V1, latch mode 160 Short circuit %Amax V2, auto-recovery 110 150 Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C Remote Sense Short Circuit Protection Complies Remote Sense Reverse Connection Protection Complies ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Chassis 1500 Primary to Secondary (2xMOPP) 4000 Isolation VAC Secondary to Chassis 1500 Output to Output 1500 Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A www.murata-ps.com/support PQC250.A13 Page 2 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply CURRENT SHARING OPTION ? PQC250-XX-DXX Model Number Description Main Output current share is achieved using ?the droop method?. Nominal output voltage is achieved at 50% load and output voltage increases/decreases approximately ?3% of nominal voltage. This regulation window does not include the additional tolerance due to line, temperature, long term stability etc. PQC250-XX-Dxx Startup of parallel power supplies is not internally synchronized. If more than 250W combined power is needed, start-up synchronization must be provided Refer to ACAN-78 by system using a common PS_ON signal. To account for ?10% full load current sharing accuracy and the reduction in full load output voltage due to for additional droop, available output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense details connected to the common load. ORing protection is available on the PQC250-xxDRT models (see Application notes, ACAN-78 for additional details); Aux (V2) output can be tied together for redundancy but total combined output power must not exceed 2.5W, external ORing devices are recommended to preserve redundancy. EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies EN 55022 Class B Conducted Emissions FCC Part 15 Class B CISPR 22 -3 meter Class B Radiated Emissions FCC 15.109 - 3 meter Class B ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion 2 Radiated Field Immunity IEC/EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 4, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A (Com. Mode: 2kV 12 OHM, Diff. Mode: 1kV, 2 OHM) Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3, 10V/m, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 3, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B EMI CONSIDERATIONS For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with EN55022 class B radiated emissions with a metal enclosure with grounded base plate. See PQC-COVER for details - testing was based on adding a toroid, Fair- Rite#5961004901 with five turns of both of the output leads. Radiated emission results vary with system enclosure and cable routing paths. EMI CONSIDE STATUS AND CONTROL SIGNALS Parameter Models Conditions This pin must be pulled low (sink current >2mA) to +5V_AUX_RTN to turn on the main output. The +5V_AUX output is independent of the PS_ON PS_ON All Models signal, and comes up automatically when the input AC or input DC voltage is applied within their specified operating ranges. Open collector logic goes high 40-100ms after the main output is within regulation; it goes low at least 2msecs before loss of regulation. Internal PWR_OK All Models 10K pull up to +5V_Aux is provided. Applications using the PWR_OK signal should maintain a minimum load of 5W on the main output. PART NUMBER STRUCTURE PQC 250 - xx - yyy Options 1 D = Droop DRT = ORing; Droop; Output Terminal Block 2 H = DC input Link back to Input_Table PQC= ?Power, Quality, Convection Cooled? Main Output Voltage (12, 18, 24, 36, 48, 54) Output Power (Watts) Examples: PQC250-24 = Base 24V Model; no options PQC250-24D = Base model, 24V Model with Droop Current Share option PQC250-24DRT= Base model, 24V Model with Droop Current Share, ORing isolation and Terminal Block options 1 not available for 18V model 2 CCC Certification not included for ?H? models and 30V models www.murata-ps.com/support PQC250.A13 Page 3 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED) Parameter Conditions Typ. Max. Units 1 Transient Response 50% load step, 1A/?sec slew rate and min 0.1A load ? 5 % Settling Time to 1% of Nominal 500 ?sec Turn On Delay After application of input power 3 sec Output Voltage Rise Monotonic 50 msec Compensates for up to 120mV of total lead drop (output and return connections) with 120 mV remote sense connected. Protected against short circuit and reverse connection. Remote Sense 1 Min. 1 second time between consecutive transients. ENVIRONMENTAL CHARACTERISTICS Min. Typ. Max. Parameter Conditions Units Storage Temperature Range -40 85 See power derating curves -10 70 ?C Start up with -20C @ 100VAC minimum input Operating Temperature Range -20 - *contact Murata for lower operating temperature range 10 95 Operating Humidity Non-condensing % 2 -200 5000 Operating Altitude m 2,145K Telcordia SR-332 Issue 3; M1C3 @ 40?C MTBF Hours 4,500K Telcordia SR-332 Issue 3; M1C3 @ 25?C Shock 30G, non-operating Complies Sine Sweep; 5-150Hz, 2G Operational Vibration Complies Random Vibration, 5-500Hz, 1.11G th IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition 3 Safety ? Medical Standards EMC Standard Requirements ) 2 x MOPP (Primary-Secondary) CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition EN60601-1:2006+CORR:2010 IEC/EN/UL/CSA 60950-1 Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1 Consumer Standards CE Marking per LVD 1 IEC62368-1 Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal Weight (typ.) 0.352/0.78 kg/lbs 1 Planned submission, contact Murata for additional details 2 3000 M max. altitude for Medical applications 3 when deployed in End User Systems PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units V1 (main output) latching 115 140 % Over Voltage Protection V2 (aux output) latching 5.5 7.5 V V1, hiccup mode 120 150 Over Current Protection V1, latch mode 160 Short circuit %Amax V2, auto-recovery 110 150 Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C Remote Sense Short Circuit Protection Complies Remote Sense Reverse Connection Protection Complies ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Chassis 1500 Primary to Secondary (2xMOPP) 4000 Isolation VAC Secondary to Chassis 1500 Output to Output 1500 Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A www.murata-ps.com/support PQC250.A13 Page 2 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply DESCRIPTION The PQC250 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency and low power dissipation in both operational and standby operation in a compact 3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom, consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC standards. ORDERING GUIDE (BASIC MODEL NUMBER) Main output (V1) Aux Output (V2) Max. Load Current Current Current Voltage Capacitance Model Number @ 50?C @ 70?C V 50?C and 70?C DC Main output VDC 1 250W 200W 16.7A PQC250-12-xxx 12 20.8A 6000?F PQC250-18-xxx 18 13.8A 11.1A 1,600uF PQC250-24-xxx 24 10.4A 8.3A 1200?F 5 0.5A PQC250-30-xxx 30 8.33A 6.6A 1000?F PQC250-36-xxx 36 6.9A 5.6A 1000?F PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details 1 Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details 2 29V model available, consult with factory for more information INPUT CHARACTERISTICS FEATURES Parameter Conditions Min Nom Max Units ? Industry leading MTBF Input Voltage AC Operating Range Single Phase 90 100/240 264 V ? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz ? 60950-1 compliant Turn-on input voltage Input rising 75 90 V AC ? IEC60335-1 Certificate Turn-off input voltage Input falling 65 80 VAC th 2 1 ? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300 1 Standard Requirements Part_Number_Options_Guide 260 400 ? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms AC 2 ? Very low no load standby power; designed to meet Maximum input current Vin = 127-300 2.7 A ? 2 ENERGY STAR Program Requirements for Single Voltage Vin = 260-400 1.5 A External AC-DC Power Supplies Inrush Current 230V ,Cold start, 25?C; 30 Apk AC ? True zero load operation of the Main (V1) output; no Power Factor At 115VAC, full load 0.95 W/VA minimum load requirements Hold-up Time 90V ; Full Load 16 msec AC ? 3" x 5" industry standard footprint 20% Full Load 88.5 Efficiency @ 230V for PQC250-48 AC ? Optional DC input capability 50% Full Load 94 % model. ? High ef?ciency 94% typical 100% Full Load 95 ? Remote sense, main output No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W ? Universal AC input with active PFC 1 ? Less than 1U high Consult with factory for details and availability 2 Medical certification applies to AC input models only. ? RoHS compliant OUTPUT CHARACTERISTICS ? Active inrush protection ,1 Parameter Conditions Min Nom Max Units ? Compatibility with MVAC250 Series products 1 Main (V1) Output ?1 ? Droop current share, output Terminal block option Line, Load Regulation % Aux (V2) Output ?5 ? Two-year warranty Minimum Load Capability Stable Operation 0 A 1 3 2 fan output of MVAC250 series not available on this product Output Ripple Zero to Full Load 1% mVP-P 1 zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load current is required to keep output voltage within ?1%. CB Test Certificate and Test Reports available upon request 2 Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used. 3 1% of nominal output voltage. AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS) Aux Output Line, Load, Cross Ripple Voltage & Auxiliary Output Load Current Load Capacitance Voltage Regulation Noise Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p M Available now at www.murata-ps.com/en/3d/acdc.html 12V Model Certificate and Test Report Applies to AC Input models For full details go to www.murata-ps.com/rohs www.murata-ps.com/support PQC250.A13 Page 1 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED) Parameter Conditions Typ. Max. Units 1 Transient Response 50% load step, 1A/?sec slew rate and min 0.1A load ? 5 % Settling Time to 1% of Nominal 500 ?sec Turn On Delay After application of input power 3 sec Output Voltage Rise Monotonic 50 msec Compensates for up to 120mV of total lead drop (output and return connections) with 120 mV remote sense connected. Protected against short circuit and reverse connection. Remote Sense 1 Min. 1 second time between consecutive transients. ENVIRONMENTAL CHARACTERISTICS Min. Typ. Max. Parameter Conditions Units Storage Temperature Range -40 85 See power derating curves -10 70 ?C Start up with -20C @ 100VAC minimum input Operating Temperature Range -20 - *contact Murata for lower operating temperature range 10 95 Operating Humidity Non-condensing % 2 -200 5000 Operating Altitude m 2,145K Telcordia SR-332 Issue 3; M1C3 @ 40?C MTBF Hours 4,500K Telcordia SR-332 Issue 3; M1C3 @ 25?C Shock 30G, non-operating Complies Sine Sweep; 5-150Hz, 2G Operational Vibration Complies Random Vibration, 5-500Hz, 1.11G th IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition 3 Safety ? Medical Standards EMC Standard Requirements ) 2 x MOPP (Primary-Secondary) CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition EN60601-1:2006+CORR:2010 IEC/EN/UL/CSA 60950-1 Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1 Consumer Standards CE Marking per LVD 1 IEC62368-1 Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal Weight (typ.) 0.352/0.78 kg/lbs 1 Planned submission, contact Murata for additional details 2 3000 M max. altitude for Medical applications 3 when deployed in End User Systems PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units V1 (main output) latching 115 140 % Over Voltage Protection V2 (aux output) latching 5.5 7.5 V V1, hiccup mode 120 150 Over Current Protection V1, latch mode 160 Short circuit %Amax V2, auto-recovery 110 150 Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C Remote Sense Short Circuit Protection Complies Remote Sense Reverse Connection Protection Complies ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Chassis 1500 Primary to Secondary (2xMOPP) 4000 Isolation VAC Secondary to Chassis 1500 Output to Output 1500 Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A www.murata-ps.com/support PQC250.A13 Page 2 of 8 PQC250 Series 250W 3" x 5" Convection Cooled AC-DC Power Supply CURRENT SHARING OPTION ? PQC250-XX-DXX Model Number Description Main Output current share is achieved using ?the droop method?. Nominal output voltage is achieved at 50% load and output voltage increases/decreases approximately ?3% of nominal voltage. This regulation window does not include the additional tolerance due to line, temperature, long term stability etc. PQC250-XX-Dxx Startup of parallel power supplies is not internally synchronized. If more than 250W combined power is needed, start-up synchronization must be provided Refer to ACAN-78 by system using a common PS_ON signal. To account for ?10% full load current sharing accuracy and the reduction in full load output voltage due to for additional droop, available output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense details connected to the common load. ORing protection is available on the PQC250-xxDRT models (see Application notes, ACAN-78 for additional details); Aux (V2) output can be tied together for redundancy but total combined output power must not exceed 2.5W, external ORing devices are recommended to preserve redundancy. EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies EN 55022 Class B Conducted Emissions FCC Part 15 Class B CISPR 22 -3 meter Class B Radiated Emissions FCC 15.109 - 3 meter Class B ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion 2 Radiated Field Immunity IEC/EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 4, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A (Com. Mode: 2kV 12 OHM, Diff. Mode: 1kV, 2 OHM) Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3, 10V/m, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 3, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B EMI CONSIDERATIONS For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with EN55022 class B radiated emissions with a metal enclosure with grounded base plate. See PQC-COVER for details - testing was based on adding a toroid, Fair- Rite#5961004901 with five turns of both of the output leads. Radiated emission results vary with system enclosure and cable routing paths. EMI CONSIDE STATUS AND CONTROL SIGNALS Parameter Models Conditions This pin must be pulled low (sink current >2mA) to +5V_AUX_RTN to turn on the main output. The +5V_AUX output is independent of the PS_ON PS_ON All Models signal, and comes up automatically when the input AC or input DC voltage is applied within their specified operating ranges. Open collector logic goes high 40-100ms after the main output is within regulation; it goes low at least 2msecs before loss of regulation. Internal PWR_OK All Models 10K pull up to +5V_Aux is provided. Applications using the PWR_OK signal should maintain a minimum load of 5W on the main output. PART NUMBER STRUCTURE PQC 250 - xx - yyy Options 1 D = Droop DRT = ORing; Droop; Output Terminal Block 2 H = DC input Link back to Input_Table PQC= ?Power, Quality, Convection Cooled? Main Output Voltage (12, 18, 24, 36, 48, 54) Output Power (Watts) Examples: PQC250-24 = Base 24V Model; no options PQC250-24D = Base model, 24V Model with Droop Current Share option PQC250-24DRT= Base model, 24V Model with Droop Current Share, ORing isolation and Terminal Block options 1 not available for 18V model 2 CCC Certification not included for ?H? models and 30V models www.murata-ps.com/support PQC250.A13 Page 3 of 8

Tariff Concession Code
Tariff Desc

Examine
8504.40.90 POWER SUPPLIES, having BOTH of the following:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC TO DC OR DC TO DC OR DC TO AC, having ALL of the following:
(a) input voltage NOT less than 10 V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81 Goods, as follows:
(a) designed for use with equipment of 8471;
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with Australian and New Zealand Standard 60950 (AS/NZS 60950) AND Australian and New Zealand Standard ISPR 2 (AS/NZS CISPR 22), having ALL of the following:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES, having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES, DC, having BOTH of the following:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 POWER SUPPLY MODULES, having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC/48VDC
(b) output power at EITHER of the following
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

Customer Comments  

Log in or register to post comments.

Customer Reviews

No reviews yet.