PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED)
Parameter Conditions Typ. Max. Units
1
Transient Response
50% load step, 1A/?sec slew rate and min 0.1A load ? 5 %
Settling Time to 1% of Nominal 500 ?sec
Turn On Delay After application of input power 3 sec
Output Voltage Rise Monotonic 50 msec
Compensates for up to 120mV of total lead drop (output and return connections) with
120 mV
remote sense connected. Protected against short circuit and reverse connection.
Remote Sense
1
Min. 1 second time between consecutive transients.
ENVIRONMENTAL CHARACTERISTICS
Min. Typ. Max.
Parameter Conditions Units
Storage Temperature Range -40 85
See power derating curves -10 70
?C
Start up with -20C @ 100VAC minimum input
Operating Temperature Range
-20
-
*contact Murata for lower operating temperature range
10 95
Operating Humidity Non-condensing %
2
-200 5000
Operating Altitude m
2,145K
Telcordia SR-332 Issue 3; M1C3 @ 40?C
MTBF Hours
4,500K
Telcordia SR-332 Issue 3; M1C3 @ 25?C
Shock 30G, non-operating Complies
Sine Sweep; 5-150Hz, 2G
Operational Vibration Complies
Random Vibration, 5-500Hz, 1.11G
th
IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition
3
Safety ? Medical Standards EMC Standard Requirements )
2 x MOPP (Primary-Secondary)
CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition
EN60601-1:2006+CORR:2010
IEC/EN/UL/CSA 60950-1
Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1
Consumer Standards
CE Marking per LVD
1
IEC62368-1
Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V
Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal
Weight (typ.) 0.352/0.78 kg/lbs
1
Planned submission, contact Murata for additional details
2
3000 M max. altitude for Medical applications
3
when deployed in End User Systems
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
V1 (main output) latching 115 140 %
Over Voltage Protection
V2 (aux output) latching 5.5 7.5 V
V1, hiccup mode 120 150
Over Current Protection V1, latch mode 160 Short circuit %Amax
V2, auto-recovery 110 150
Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C
Remote Sense Short Circuit Protection Complies
Remote Sense Reverse Connection Protection Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Primary to Chassis 1500
Primary to Secondary (2xMOPP) 4000
Isolation
VAC
Secondary to Chassis 1500
Output to Output 1500
Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A
Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A
www.murata-ps.com/support
PQC250.A13 Page 2 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED)
Parameter Conditions Typ. Max. Units
1
Transient Response
50% load step, 1A/?sec slew rate and min 0.1A load ? 5 %
Settling Time to 1% of Nominal 500 ?sec
Turn On Delay After application of input power 3 sec
Output Voltage Rise Monotonic 50 msec
Compensates for up to 120mV of total lead drop (output and return connections) with
120 mV
remote sense connected. Protected against short circuit and reverse connection.
Remote Sense
1
Min. 1 second time between consecutive transients.
ENVIRONMENTAL CHARACTERISTICS
Min. Typ. Max.
Parameter Conditions Units
Storage Temperature Range -40 85
See power derating curves -10 70
?C
Start up with -20C @ 100VAC minimum input
Operating Temperature Range
-20
-
*contact Murata for lower operating temperature range
10 95
Operating Humidity Non-condensing %
2
-200 5000
Operating Altitude m
2,145K
Telcordia SR-332 Issue 3; M1C3 @ 40?C
MTBF Hours
4,500K
Telcordia SR-332 Issue 3; M1C3 @ 25?C
Shock 30G, non-operating Complies
Sine Sweep; 5-150Hz, 2G
Operational Vibration Complies
Random Vibration, 5-500Hz, 1.11G
th
IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition
3
Safety ? Medical Standards EMC Standard Requirements )
2 x MOPP (Primary-Secondary)
CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition
EN60601-1:2006+CORR:2010
IEC/EN/UL/CSA 60950-1
Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1
Consumer Standards
CE Marking per LVD
1
IEC62368-1
Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V
Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal
Weight (typ.) 0.352/0.78 kg/lbs
1
Planned submission, contact Murata for additional details
2
3000 M max. altitude for Medical applications
3
when deployed in End User Systems
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
V1 (main output) latching 115 140 %
Over Voltage Protection
V2 (aux output) latching 5.5 7.5 V
V1, hiccup mode 120 150
Over Current Protection V1, latch mode 160 Short circuit %Amax
V2, auto-recovery 110 150
Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C
Remote Sense Short Circuit Protection Complies
Remote Sense Reverse Connection Protection Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Primary to Chassis 1500
Primary to Secondary (2xMOPP) 4000
Isolation
VAC
Secondary to Chassis 1500
Output to Output 1500
Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A
Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A
www.murata-ps.com/support
PQC250.A13 Page 2 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
CURRENT SHARING OPTION ? PQC250-XX-DXX
Model Number Description
Main Output current share is achieved using ?the droop method?. Nominal output voltage is achieved at 50% load and output voltage increases/decreases
approximately ?3% of nominal voltage. This regulation window does not include the additional tolerance due to line, temperature, long term stability etc.
PQC250-XX-Dxx Startup of parallel power supplies is not internally synchronized. If more than 250W combined power is needed, start-up synchronization must be provided
Refer to ACAN-78 by system using a common PS_ON signal. To account for ?10% full load current sharing accuracy and the reduction in full load output voltage due to
for additional droop, available output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense
details connected to the common load.
ORing protection is available on the PQC250-xxDRT models (see Application notes, ACAN-78 for additional details);
Aux (V2) output can be tied together for redundancy but total combined output power must not exceed 2.5W, external ORing devices are recommended to
preserve redundancy.
EMISSIONS AND IMMUNITY
Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
EN 55022 Class B
Conducted Emissions
FCC Part 15 Class B
CISPR 22 -3 meter Class B
Radiated Emissions
FCC 15.109 - 3 meter Class B
ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion 2
Radiated Field Immunity IEC/EN 61000-4-3 Level 3, Criterion A
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 4, Criterion A
Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A (Com. Mode: 2kV 12 OHM, Diff.
Mode: 1kV, 2 OHM)
Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3, 10V/m, Criterion A
Magnetic Field Immunity IEC/EN 61000-4-8 Level 3, Criterion A
Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards,
this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with
EN55022 class B radiated emissions with a metal enclosure with grounded base plate. See PQC-COVER for details - testing was based on adding a toroid, Fair-
Rite#5961004901 with five turns of both of the output leads. Radiated emission results vary with system enclosure and cable routing paths.
EMI CONSIDE
STATUS AND CONTROL SIGNALS
Parameter Models Conditions
This pin must be pulled low (sink current >2mA) to +5V_AUX_RTN to turn on the main output. The +5V_AUX output is independent of the PS_ON
PS_ON All Models
signal, and comes up automatically when the input AC or input DC voltage is applied within their specified operating ranges.
Open collector logic goes high 40-100ms after the main output is within regulation; it goes low at least 2msecs before loss of regulation. Internal
PWR_OK All Models
10K pull up to +5V_Aux is provided. Applications using the PWR_OK signal should maintain a minimum load of 5W on the main output.
PART NUMBER STRUCTURE
PQC 250 - xx - yyy
Options
1
D = Droop
DRT = ORing; Droop; Output Terminal Block
2
H = DC input Link back to Input_Table
PQC= ?Power, Quality, Convection Cooled? Main Output Voltage
(12, 18, 24, 36, 48, 54)
Output Power (Watts)
Examples: PQC250-24 = Base 24V Model; no options
PQC250-24D = Base model, 24V Model with Droop Current Share option
PQC250-24DRT= Base model, 24V Model with Droop Current Share, ORing isolation and Terminal Block options
1
not available for 18V model
2
CCC Certification not included for ?H? models and 30V models
www.murata-ps.com/support
PQC250.A13 Page 3 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED)
Parameter Conditions Typ. Max. Units
1
Transient Response
50% load step, 1A/?sec slew rate and min 0.1A load ? 5 %
Settling Time to 1% of Nominal 500 ?sec
Turn On Delay After application of input power 3 sec
Output Voltage Rise Monotonic 50 msec
Compensates for up to 120mV of total lead drop (output and return connections) with
120 mV
remote sense connected. Protected against short circuit and reverse connection.
Remote Sense
1
Min. 1 second time between consecutive transients.
ENVIRONMENTAL CHARACTERISTICS
Min. Typ. Max.
Parameter Conditions Units
Storage Temperature Range -40 85
See power derating curves -10 70
?C
Start up with -20C @ 100VAC minimum input
Operating Temperature Range
-20
-
*contact Murata for lower operating temperature range
10 95
Operating Humidity Non-condensing %
2
-200 5000
Operating Altitude m
2,145K
Telcordia SR-332 Issue 3; M1C3 @ 40?C
MTBF Hours
4,500K
Telcordia SR-332 Issue 3; M1C3 @ 25?C
Shock 30G, non-operating Complies
Sine Sweep; 5-150Hz, 2G
Operational Vibration Complies
Random Vibration, 5-500Hz, 1.11G
th
IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition
3
Safety ? Medical Standards EMC Standard Requirements )
2 x MOPP (Primary-Secondary)
CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition
EN60601-1:2006+CORR:2010
IEC/EN/UL/CSA 60950-1
Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1
Consumer Standards
CE Marking per LVD
1
IEC62368-1
Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V
Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal
Weight (typ.) 0.352/0.78 kg/lbs
1
Planned submission, contact Murata for additional details
2
3000 M max. altitude for Medical applications
3
when deployed in End User Systems
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
V1 (main output) latching 115 140 %
Over Voltage Protection
V2 (aux output) latching 5.5 7.5 V
V1, hiccup mode 120 150
Over Current Protection V1, latch mode 160 Short circuit %Amax
V2, auto-recovery 110 150
Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C
Remote Sense Short Circuit Protection Complies
Remote Sense Reverse Connection Protection Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Primary to Chassis 1500
Primary to Secondary (2xMOPP) 4000
Isolation
VAC
Secondary to Chassis 1500
Output to Output 1500
Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A
Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A
www.murata-ps.com/support
PQC250.A13 Page 2 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
DESCRIPTION
The PQC250 series switching power supplies utilize advanced component and circuit technologies to
deliver high efficiency and low power dissipation in both operational and standby operation in a compact
3.0" x 5.0" x 1.40" package. Designed for industrial, medical, computing, communications, telecom,
consumer, and other OEM applications, deployable in 1U customer systems. All models offer universal AC
input capability with active power factor correction (PFC) and compliance to worldwide safety and EMC
standards.
ORDERING GUIDE (BASIC MODEL NUMBER)
Main output (V1) Aux Output (V2)
Max. Load
Current Current Current
Voltage Capacitance
Model Number @ 50?C @ 70?C V 50?C and 70?C
DC
Main output
VDC
1
250W 200W
16.7A
PQC250-12-xxx 12 20.8A 6000?F
PQC250-18-xxx 18 13.8A 11.1A 1,600uF
PQC250-24-xxx 24 10.4A 8.3A 1200?F
5 0.5A
PQC250-30-xxx 30 8.33A 6.6A 1000?F
PQC250-36-xxx 36 6.9A 5.6A 1000?F
PQC250-48-xxx (PoE Compliant) 48 5.2A 4.2A 750?F
PQC250-54-xxx (PoE Compliant) 54 4.6A 3.7A 500?F
PQC-COVER Optional cover kit assembly see PQC-COVER datasheet for details
1
Output De-Rating at 70?C is for horizontal orientation with component side up only. Please refer to ACAN-77 for details
2
29V model available, consult with factory for more information
INPUT CHARACTERISTICS
FEATURES
Parameter Conditions Min Nom Max Units
? Industry leading MTBF
Input Voltage AC Operating Range Single Phase 90 100/240 264 V
? Certified to IEC60601 Ed.3 medical (2 x MOPP Pri-Sec; 1 x AC
MOPP Pri-Chassis Ground), AC input models. Input Frequency 47 50/60 63 Hz
? 60950-1 compliant Turn-on input voltage Input rising 75 90 V
AC
? IEC60335-1 Certificate
Turn-off input voltage Input falling 65 80 VAC
th 2 1
? Designed to comply with IEC60601-1-2 4 Edition EMC DC input refer to: 127 300
1
Standard Requirements Part_Number_Options_Guide 260 400
? 250W Convection, 100Vac to 264Vac +50C operation Vin = 115V ; Full Load 2.5 Arms
AC
2
? Very low no load standby power; designed to meet
Maximum input current Vin = 127-300 2.7 A
?
2
ENERGY STAR Program Requirements for Single Voltage
Vin = 260-400 1.5 A
External AC-DC Power Supplies
Inrush Current 230V ,Cold start, 25?C; 30 Apk
AC
? True zero load operation of the Main (V1) output; no
Power Factor At 115VAC, full load 0.95 W/VA
minimum load requirements
Hold-up Time 90V ; Full Load 16 msec
AC
? 3" x 5" industry standard footprint
20% Full Load 88.5
Efficiency @ 230V for PQC250-48
AC
? Optional DC input capability
50% Full Load 94 %
model.
? High ef?ciency 94% typical
100% Full Load 95
? Remote sense, main output
No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
? Universal AC input with active PFC
1
? Less than 1U high Consult with factory for details and availability
2
Medical certification applies to AC input models only.
? RoHS compliant
OUTPUT CHARACTERISTICS
? Active inrush protection
,1 Parameter Conditions Min Nom Max Units
? Compatibility with MVAC250 Series products
1
Main (V1) Output ?1
? Droop current share, output Terminal block option
Line, Load Regulation %
Aux (V2) Output ?5
? Two-year warranty
Minimum Load Capability Stable Operation 0 A
1 3 2
fan output of MVAC250 series not available on this product
Output Ripple Zero to Full Load 1% mVP-P
1
zero load output voltage may exceed the regulation window however will not cause OVP to engage or PWROK to change to low state. 200mA min. load
current is required to keep output voltage within ?1%.
CB Test Certificate and Test Reports available upon request
2
Ripple and noise are measured with 0.1uF ceramic capacitor and 10uF tantalum capacitor. A short coaxial cable with 50 ohm termination is used.
3
1% of nominal output voltage.
AUXILIARY OUTPUT CHARACTERISTICS (ALL MODELS)
Aux Output Line, Load, Cross Ripple Voltage &
Auxiliary Output Load Current Load Capacitance
Voltage Regulation Noise
Aux (V2) 5V 0 to 0.5A 0 to 220?F ? 5% 120mVp-p
M
Available now at www.murata-ps.com/en/3d/acdc.html
12V Model
Certificate and Test Report
Applies to AC Input models
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
PQC250.A13 Page 1 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT WHERE NOTED)
Parameter Conditions Typ. Max. Units
1
Transient Response
50% load step, 1A/?sec slew rate and min 0.1A load ? 5 %
Settling Time to 1% of Nominal 500 ?sec
Turn On Delay After application of input power 3 sec
Output Voltage Rise Monotonic 50 msec
Compensates for up to 120mV of total lead drop (output and return connections) with
120 mV
remote sense connected. Protected against short circuit and reverse connection.
Remote Sense
1
Min. 1 second time between consecutive transients.
ENVIRONMENTAL CHARACTERISTICS
Min. Typ. Max.
Parameter Conditions Units
Storage Temperature Range -40 85
See power derating curves -10 70
?C
Start up with -20C @ 100VAC minimum input
Operating Temperature Range
-20
-
*contact Murata for lower operating temperature range
10 95
Operating Humidity Non-condensing %
2
-200 5000
Operating Altitude m
2,145K
Telcordia SR-332 Issue 3; M1C3 @ 40?C
MTBF Hours
4,500K
Telcordia SR-332 Issue 3; M1C3 @ 25?C
Shock 30G, non-operating Complies
Sine Sweep; 5-150Hz, 2G
Operational Vibration Complies
Random Vibration, 5-500Hz, 1.11G
th
IEC60601-1 (Ed. 3) ? CB Cert and Report ANSI/AAMI ES60601-1 (2005+C1:09+A2:10) (Designed to comply with IEC60601-1-2 4 Edition
3
Safety ? Medical Standards EMC Standard Requirements )
2 x MOPP (Primary-Secondary)
CAN/CSA 22.2 No. 60601-1 (2008) 3rd Edition
EN60601-1:2006+CORR:2010
IEC/EN/UL/CSA 60950-1
Safety ? ITE, Audio/Video & IEC/EN/UL/CSA 60335-1
Consumer Standards
CE Marking per LVD
1
IEC62368-1
Fuses Dual Fuses; Line and Neutral; 6.3A Time Lag; 250V
Outside Dimensions 3.0" x 5.0" x 1.44" (76.2mm x 127mm x 35.2mm) nominal
Weight (typ.) 0.352/0.78 kg/lbs
1
Planned submission, contact Murata for additional details
2
3000 M max. altitude for Medical applications
3
when deployed in End User Systems
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
V1 (main output) latching 115 140 %
Over Voltage Protection
V2 (aux output) latching 5.5 7.5 V
V1, hiccup mode 120 150
Over Current Protection V1, latch mode 160 Short circuit %Amax
V2, auto-recovery 110 150
Over Temperature Protection (Primary and Secondary Heatskink Temperature) Auto-recovery 125 130 ?C
Remote Sense Short Circuit Protection Complies
Remote Sense Reverse Connection Protection Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Primary to Chassis 1500
Primary to Secondary (2xMOPP) 4000
Isolation
VAC
Secondary to Chassis 1500
Output to Output 1500
Earth Leakage Current (under single fault condition) 264VAC, 60Hz, 25?C 300 ?A
Earth Leakage Current (under normal conditions) 264VAC, 60Hz, 25?C 150 ?A
www.murata-ps.com/support
PQC250.A13 Page 2 of 8 PQC250 Series
250W 3" x 5" Convection Cooled AC-DC Power Supply
CURRENT SHARING OPTION ? PQC250-XX-DXX
Model Number Description
Main Output current share is achieved using ?the droop method?. Nominal output voltage is achieved at 50% load and output voltage increases/decreases
approximately ?3% of nominal voltage. This regulation window does not include the additional tolerance due to line, temperature, long term stability etc.
PQC250-XX-Dxx Startup of parallel power supplies is not internally synchronized. If more than 250W combined power is needed, start-up synchronization must be provided
Refer to ACAN-78 by system using a common PS_ON signal. To account for ?10% full load current sharing accuracy and the reduction in full load output voltage due to
for additional droop, available output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense
details connected to the common load.
ORing protection is available on the PQC250-xxDRT models (see Application notes, ACAN-78 for additional details);
Aux (V2) output can be tied together for redundancy but total combined output power must not exceed 2.5W, external ORing devices are recommended to
preserve redundancy.
EMISSIONS AND IMMUNITY
Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
EN 55022 Class B
Conducted Emissions
FCC Part 15 Class B
CISPR 22 -3 meter Class B
Radiated Emissions
FCC 15.109 - 3 meter Class B
ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion 2
Radiated Field Immunity IEC/EN 61000-4-3 Level 3, Criterion A
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 4, Criterion A
Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A (Com. Mode: 2kV 12 OHM, Diff.
Mode: 1kV, 2 OHM)
Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3, 10V/m, Criterion A
Magnetic Field Immunity IEC/EN 61000-4-8 Level 3, Criterion A
Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards,
this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with
EN55022 class B radiated emissions with a metal enclosure with grounded base plate. See PQC-COVER for details - testing was based on adding a toroid, Fair-
Rite#5961004901 with five turns of both of the output leads. Radiated emission results vary with system enclosure and cable routing paths.
EMI CONSIDE
STATUS AND CONTROL SIGNALS
Parameter Models Conditions
This pin must be pulled low (sink current >2mA) to +5V_AUX_RTN to turn on the main output. The +5V_AUX output is independent of the PS_ON
PS_ON All Models
signal, and comes up automatically when the input AC or input DC voltage is applied within their specified operating ranges.
Open collector logic goes high 40-100ms after the main output is within regulation; it goes low at least 2msecs before loss of regulation. Internal
PWR_OK All Models
10K pull up to +5V_Aux is provided. Applications using the PWR_OK signal should maintain a minimum load of 5W on the main output.
PART NUMBER STRUCTURE
PQC 250 - xx - yyy
Options
1
D = Droop
DRT = ORing; Droop; Output Terminal Block
2
H = DC input Link back to Input_Table
PQC= ?Power, Quality, Convection Cooled? Main Output Voltage
(12, 18, 24, 36, 48, 54)
Output Power (Watts)
Examples: PQC250-24 = Base 24V Model; no options
PQC250-24D = Base model, 24V Model with Droop Current Share option
PQC250-24DRT= Base model, 24V Model with Droop Current Share, ORing isolation and Terminal Block options
1
not available for 18V model
2
CCC Certification not included for ?H? models and 30V models
www.murata-ps.com/support
PQC250.A13 Page 3 of 8