DC-DC Converter XPPower RDH600 Series 600 Watts Wide 4:1 Input Range xxx Series Covers 72 & 110VDC for Rail Applications Complies with EN50155 Meets EN50121-3-2 Single Output Industry Standard Full Brick -40C to +100C Operation Output Trim 60-110% Remote On/Off Dimensions: 3 Year Warranty RDH600: 2.4 x 4.6 x 0.5 (61.0 x 116.8 x 12.7 mm) The RDH600 family of DC-DC converters offers an EN50155 compliant solution in an industry standard format. The construction is robust and designed for harsh environments. Models & Ratings Input Current Input Output Ripple & Max. capacitive (2) Output Current Efficiency Model Number (1) Voltage Voltage noise load (3) No Load Full Load 12 V 50.0 A 25 mA 16.00 A 120 mV 87% 10000 F RDH60072WS12 24 V 25.0 A 25 mA 15.85 A 240 mV 88% 5000 F RDH60072WS24 43-160 V 28 V 21.4 A 25 mA 15.85 A 280 mV 88% 5000 F RDH60072WS28 48 V 12.5 A 25 mA 15.85 A 480 mV 88% 5000 F RDH60072WS48 Notes 1. Measured at 20 MHz bandwidth pk-pk, full load, 10 F aluminum solid and 1.0 F 2. Measured at 110 V input and full load. ceramic capacitors. 3. Measured at 43 VDC input. Mechanical Details 0.301 7.64 0.150 3.81 0.150 3.81 0.050 0.150 3.81 1.27 0.400 10.16 2.40 Pin Function 0.100 61.0 0.150 3.81 2.54 2.00 1 -Vin 50.8 0.300 2 +Vin 0.150 3.81 7.62 -Vin 3 REM- 0.900 0.150 22.86 4 REM+ 0.400 3.81 +Vin 10.16 5-7 +Vout - 8-10 -Vout 1.400 0.201 35.56 11 -Sense + 5.10 12 +Sense 13 Trim 14 Current Share 15 Power Good 0.199 5.05 16 Auxilliary, 7-13 V/20 mA Mounting Inserts 4.20 106.7 3.5 through 4pl. 0.22 5.5 4.60 116.8 Notes 1. All dimensions are in inches (mm) 3. Tolerance: x.xx = 0.02 (x.x = 0.5) 2. Weight: 0.485 lbs (220 g) approx. x.xxx = 0.01 (x.xx = 0.25) www.xppower.com 1 0.50 12.7 ON/OFFDC-DC Converter XPPower RDH600 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage Range 43 160 VDC 72/110 V nominal inputs Input Surge 180 VDC for 100 ms On: >41 V 42 43 On Undervoltage Lockout VDC Off: <39 V 40 41 Off Lockout Hysteresis 2 VDC Idle Current 1 10 mA When output is inhibited 2 Inrush Current 1 A s Recommended Input Fuse 20 A Time delay Input Reflected Ripple Current 40 mA pk-pk Through 12 H inductor Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Output Trim -40 +10 % See Application Note Initial Set Accuracy 1.5 % At full load and 110 V input Minimum Load 0 % No minimum load required Line Regulation 0.2 % From minimum to maximum input at full load Load Regulation 0.5 % From 0% to full load Maximum deviation, recovering to less than 1% in Transient Response 3.0 5.0 % 500 s for 25% step load change. Start Up Time 250 ms Output Voltage Rise Time 50 ms Ripple & Noise mV pk-pk See models and ratings table Overload Protection 110 125 160 % Short Circuit Protection Continuous hiccup mode, with auto recovery Maximum Capacitive Load See Models and Ratings table Temperature Coefficient 0.02 %/ C Overvoltage Protection 115 125 140 % Ouput is on if REM+ (pin 4) is open or high (3.5-75 VDC) WRT REM- (pin 3) or -Vin Remote On/Off Output turns off if REM+ (pin 4) is low (<1.2 VDC max) WRT REM- (pin 3) or -Vin Positive logic turns the module off if a current of 1 and 10 mA is flowing between remote control pins 3 & 4. See application notes. General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 88 % See Models and Ratings table Isolation: Input to Output 2250 VDC 60 s Isolation: Input to Case 2250 VDC 60 s Isolation: Output to Case 1500 VDC 60 s 7 Isolation Resistance 10 Isolation Capacitance 4000 pF Input to output Switching Frequency 250 kHz 3 Power Density 109 W/in Mean Time Between Failure 450 kHrs MIL-HDBK-217F, +25 C GB Case Material Plastic DAP UL94V-0 with aluminium base plate Potting Material Epoxy UL94V-0 Pin Material Copper with nickel and matte tin plating Fire and Smoke Meets EN45545-2 Weight 0.485 (220.0) lb (g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Base Plate Temperature -40 +100 C Storage Temperature -55 +105 C Thermal Protection +110 C Measured on baseplate Humidity 95 %RH Non-condensing Cooling Base plate cooled Altitude 2000 m Transportation 12000 m Shock and Vibration Meets EN61373. Designed to meet MIL STD-810F www.xppower.com 2