DC/DC Converters TRV 1 Series, 1 Watt CB Scheme UL 60950-1 Features Semi-regulated output (load) Industry standard pinout High efcfi iency up to 87% I/O isolation voltage 3000 VDC Operationally reliable up to 5000m altitude Operating temperature range 40C to +85C 3-year product warranty The TRV-1 series are ultra miniature, 1 Watt DC/DC-converters with high 3000VDC I/O-isolation and semi load regulation. They are the ideal solution to power drivers and circuits where unregulated DC/DC converters do not meet the input voltage range at load change. Models Ordercode Input voltage Output voltage Output current max. Efficiency typ. TRV 1-0511 5 VDC 200 mA 84 % TRV 1-0519 9 VDC 110 mA 86.5 % TRV 1-0512 5 VDC 10% 12 VDC 84 mA 87 % TRV 1-0513 15 VDC 67 mA 87.5 % TRV 1-1211 5 VDC 200 mA 84 % TRV 1-1219 9 VDC 110 mA 86 % TRV 1-1212 12 VDC 10% 12 VDC 84 mA 88 % TRV 1-1213 15 VDC 67 mA 88 % TRV 1-2411 5 VDC 200 mA 84 % TRV 1-2419 9 VDC 110 mA 86.5 % TRV 1-2412 24 VDC 10% 12 VDC 84 mA 87.5 % TRV 1-2413 15 VDC 67 mA 87.5 % DC/DC Converters TRV 1 Series 1 Watt Input Specifications Input current no load / full load 5 Vin models: 30 mA / 230 mA typ. 12 Vin models: 12 mA / 100 mA typ. 24 Vin models: 11 mA / 50 mA typ. Surge voltage (1 sec. max.) 5 Vin models: 9 V max. 12 Vin models: 18 V max. 24 Vin models: 30 V max. Reflected input ripple current 5 Vin models: 11 mA typ. other models: 5 mA typ. Input filter internal capacitors Recommended input fuse (slow blow type) 5 Vin models: 500 mA 12 Vin models: 200 mA 24 Vin models: 100 mA Output Specifications Regulation Input variation 1.2 % / 1 % change Vin Load variation see graph 1 on page 3 Ripple and noise (20 MHz Bandwidth) 60 mV pk-pk max. Temperature coefficient 0.02 %/K Short circuit protection limited 0.5 sec. max. Capacitive load 220 F max. General Specifications Temperature ranges Operating 40C to +85C (without derating) Case temperature +105C max. Storage 50C to +125C Humidity (non condensing) 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217F, at +25C, ground benign) >2000000 h Isolation voltage (60 sec.) Input/Output 3000 VDC Isolation capacitance Input/Output 60 pF typ. Isolation resistance Input/Output >1000 Mohm Switching frequency 100 kHz typ. (frequency modulation) Frequency change over line and load 50 / +20 kHz max. Altitude during operation up to 5000 m (16400 ft) approved Safety approvals IEC 60950-1:2005 (2nd edition) + Am 1:2009 EN 60950-1:2006 + Am 1:2010 + Am 11:2009 Certification documents www.tracopower.com/overview/trv1 Supporting documents: www.tracopower.com/overview/trv1 All specicfi ations valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.