MODEL TL-5955 International size reference: 2/3AA, ER14335 TECHNICAL DATA (Typical values + 25C for batteries stored for one year or less) Nominal capacity 1.3 mA, to 2 V 1.5 Ah Rated voltage 3.6 V Maximum recommended continuous current 75 mA Maximum pulse current capability 150 mA Weight 12.5 g (0.441 oz) Volume 5.2 cc Operating temperature range -55 C to +85 C Li metal content approx. 0.5 g U.L. Component Recognition, MH 12193 Volts DISCHARGE CHARACTERISTICS +25C 4.0 3.5 3.0 2.5 2.0 154 1 k 2.7 k 17 k 60 k 227 k ~20 mA ~3.3 mA ~1.3 mA ~0.2 mA ~60 A ~16 A (1.20 Ah) (1.50Ah) (1.50 Ah) (1.50 Ah) (1.45 Ah) (1.20 Ah) TERMINATIONS & ORDERING NO. 1.5 SUFFIX- /S STANDARD 15-5955-21500 SUFFIX- /T SOLDER TABS 15-5955-31500 1.0 SUFFIX- /P AXIAL PINS 15-5955-41500 1 10 100 1000 10000 100000 SUFFIX- /PT2 RADIAL PINS 15-5955-36500 Hours SUFFIX- /TP POLARIZED TABS 15-5955-52500 SUFFIX- /PT POLARIZED TABS 15-5955-53500 Volts Ah VOLTAGE VS. TEMPERATURE CAPACITY VS. CURRENT 3.7 1.5 -30 C 3.5 5 A 1.2 21 A 3.3 25 C 1 mA 0.9 3.1 55 C 2.5 mA 0.6 72 C 2.9 5 mA 17 mA 2.7 0.3 -50 -30 -10 103050 7090 0.01 0.1 1 10 C mA iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. D 11/08 Page 1 of 2 TL-5955 CELL FEATURES 3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate MAIN APPLICATIONS Bobbin construction Utility meters (elect., water & Hermetic glass-to-metal-sealing gas) Non-flammable electrolyte Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Volts VOLTAGE RESPONSE AFTER STORAGE Wireless security systems 3.5 After 1 year Automotive electronics After 2 years 3.4 Industrial electronics After 5 years 3.3 Ultra Low Power (ULP) After 10 years 3.2 3.1 STORAGE CONDITIONS 3.0 Cells should be stored in a clean & dry (less than 30 % 2.9 Pulse applied: 15 mA for 1 sec RH) area Storage: RT 2.8 Background current: None 2.7 2.6 For updated information please visit 0 200 400 600 800 1000 1200 our website www.tadiranbat.com msec Volts Volts VOLTAGE RESPONSE VOLTAGE RESPONSE 3.5 3.5 After 5 years After 1 year 3.4 3.4 After 1 year After 5 years After 7 years After 2 years After 10 years 3.3 3.3 Pulse applied: 15 mA for 100 msec Pulse applied: 15 mA for 100 msec 3.2 3.2 Temperature: RT Temperature: RT Background current: 7.5 A Background current: 15 A 3.1 3.1 0 20 40 60 80 100 120 0 20 40 60 80 100 120 msec msec iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. D 11/08 Page 2 of 2