Ships to you between Tue. 21 May to Mon. 27 May
3RV2011-0HA10 Siemens
Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:26A Stock : 40
Motor breaker; 0.55kW; 220÷690VAC; DIN; Short circ.release:21A Stock : 77
Motor breaker; 0.18kW; Auxiliary contacts: NO + NC; 220÷690VAC Stock : 0
Motor breaker; 0.25kW; 220÷690VAC; DIN; Short circ.release:13A Stock : 22
Motor breaker; 0.25kW; Auxiliary contacts: NO + NC; 220÷690VAC Stock : 15
Motor breaker; 0.37kW; 220÷690VAC; DIN; Short circ.release:16A Stock : 17
Motor breaker; 0.37kW; Auxiliary contacts: NO + NC; 220÷690VAC Stock : 6
Motor breaker; 0.55kW; Auxiliary contacts: NO + NC; 220÷690VAC Stock : 23
Motor breaker; 0.75kW; Auxiliary contacts: NO + NC; 220÷690VAC Stock : 6
Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:33A Stock : 14
Motor breaker; 3kW; 220÷690VAC; DIN; Overcurrent release:5.5÷8A Stock : 21
Motor breaker; 11kW; 220÷690VAC; DIN; Overcurrent release:18÷25A Stock : 31
Motor breaker; 4kW; 220÷690VAC; DIN; Overcurrent release:7÷10A Stock : 0
Schurter Circuit Breaker Accessories CBE TA35-CZZ11 Stock : 287
Circuit Breaker Accessories CBE TA35-CZZ21 Stock : 703
Circuit Breaker Accessories Stock : 140
Motor breaker; 0.12kW; 220÷440VAC; DIN; 0.4÷0.63A; IP20; -25÷50°C Stock : 2
Motor breaker; 4kW; 220÷440VAC; DIN; 6.3÷10A; IP20; -25÷50°C Stock : 7
Motor breaker; 0.55kW; 220÷440VAC; DIN; 1÷1.6A; IP20; -25÷50°C Stock : 3
Product data sheet 3RV2011-0HA10 CIRCUIT-BREAKER SZ S00, FOR MOTOR PROTECTION, CLASS 10, A-REL. 0.55...0.8A, N-RELEASE10 A SCREW CONNECTION, STANDARD SW. CAPACITY General technical data: product brand name SIRIUS Product designation 3RV2 circuit breaker Size of the circuit-breaker S00 Number of poles / for main current circuit 3 Product function removable terminal for auxiliary and control circuit No overload protection Yes phase disturbance recognition Yes short-circuit to earth recognition No Product component auxiliary switch No undervoltage release mechanism No trip indicator No Product extension auxiliary switch Yes optional / motor drive No Impulse voltage resistance / rated value kV 6 Protection class IP / on the front IP20 Protection against electrical shock finger-safe 3RV2011-0HA10 subject to modifications Page 1/4 04/11/2014 Copyright Siemens AG 2014Installation altitude / at a height over sea level / maximum m 2,000 Ambient temperature during transport C -50 +80 during storage C -50 +80 during operating C -20 +60 Active power loss / total / typical W 5.4 Main circuit: Operating voltage / rated value V 690 Service power / at AC-3 at 400 V / rated value W 180 at 500 V / rated value W 250 at 690 V / rated value W 370 Operating current / at AC-3 / at 400 V / rated value A 0.8 Mechanical operating cycles as operating time / of the main 100,000 contacts / typical Frequency of operation / with AC-3 / maximum 1/h 15 Auxiliary circuit: Number of changeover contacts / for auxiliary contacts 0 Mechanical operating cycles as operating time / of the auxiliary 100,000 contacts / typical Protection function: Trip class CLASS 10 Adjustable response current / of the current-dependent A 0.55 0.8 overload release Safety: Proportion of dangerous failures with high demand rate / according to SN 31920 % 40 with low demand rate / according to SN 31920 % 40 Failure rate (FIT value) / with low demand rate / according to SN FIT 50 31920 B10 value / with high demand rate / according to SN 31920 50,000 T1 value / for proof test interval or service life / according to IEC a 10 61508 Installation/mounting/dimensions: Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 mounting position any Depth mm 96 Height mm 97 3RV2011-0HA10 subject to modifications Page 2/4 04/11/2014 Copyright Siemens AG 2014