Panel Mount Datasheet EZ Series Compact design for low-profile applications Ratings from 5 A to 18 A 600 VAC SCR output for heavy industrial loads AC or DC control 1/4 fast-on terminals for easy installation UL/CSA/TUV Approved, CE Compliant to EN60950-1 PRODUCT SELECTION 5 A 12 A Control Voltage 18 A 3-15 VDC EZ240D5 EZ240D12 EZ240D18 EZE240D12 EZE240D18 15-32 VDC 90-140 Vrms EZ240A12 EZ240A18 EZE240A12 EZE240A18 18-36 Vrms EZ480D12 4-15 VDC EZ480D18 EZE480D18 15-32 VDC EZE480D12 90-140 Vrms EZ480A18 EZ480A12 EZE480A18 18-36 Vrms EZE480A12 AVAILABLE OPTIONS Input Range Control Voltage Internal Snubber Blank: Standard Input D: DC 3-15 V (4-15 V for Blank: Not Included E: 18-36 VAC (AC Input) 480 V) S: Included (EZ240 only) Series 15-32 VDC (DC Input) A: AC 90-140 V E 240 A 12 R EZ S Switching Mode Load Current Operating Voltage Blank: Zero Voltage Turn-On 5: 5 Amps (EZ240D 240: 24-280 VAC -10: Random Turn-On 480: 48-660 VAC suffix only) 12: 12 Amps 18: 18 Amps Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) Description 12 A 18 A 12 A 18 A 5 A Operating Voltage (47-63Hz) Vrms 24-280 24-280 24-280 48-660 48-660 600 600 1200 1200 Transient Overvoltage Vpk 600 Maximum Off-State Leakage Current Rated Voltage mArms (4) 0.1 0.1 0.1 0.1 0.1 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (2) 500 500 500 500 500 Maximum Load Current Arms (3) 5 12 18 12 18 150 150 150 150 Minimum Load Current Arms 150 143/150 191/200 143/150 191/200 Maximum 1 Cycle Surge Current (50/60Hz) Apk 38/40 1.5 1.5 1.5 1.5 1.5 Maximum On-State Voltage Drop Rated Current Vpk 2 2 1.1 2 1.1 Thermal Resistance Junction to Case (Rjc) C/W 102/93 102/93 182/166 102/93 182/166 Maximum 1/2 Cycle It for Fusing (50/60 Hz) A sec 0.5 0.5 0.5 0.5 0.5 Minimum Power Factor (with Maximum Load) FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2021 Crydom Inc. Specifications subject to change without notice.SNUBBER SNUBBER Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description EZ240Dxx EZ480Dxx EZExxxDxx EZxxxAxx EZExxxAxx Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 Vrms 18-36 Vrms Minimum Turn-On Voltage 3.0 VDC 4.0 VDC 90.0 Vrms 18.0 Vrms 15.0 VDC Minimum Turn-Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC 10.0 Vrms 2.0 Vrms Nominal Voltage 5.0 VDC 5.0 VDC 24 VDC 120 Vrms 24 Vrms Typical Input Current Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mA 10 mA Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 10.6 k Ohm 1.8 k Ohm Maximum Turn-On Time msec (5) 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle Maximum Turn-Off Time msec 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 2500 Vrms 9 Minimum Insulation Resistance ( 500 VDC) 10 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80C Ambient Storage Temperature Range -40 to 125 C Weight (typical) 1.5 oz (43 g) Encapsulation Thermally Conductive Epoxy Terminals .25 Fastons Mounting Screw Torque (8-32 UNC screw) in lbs/Nm 8-14/1.1-1.5 GENERAL NOTES (1) All parameters at 25C unless otherwise specied. (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Heat sinking required, see derating curves. (4) Off- state leakage for snubbered version (sufx S, 240V version only) is 10.0mArms (5) Turn-on time for random turn-on versions is 0.1 msec (DC Control Models). WIRING DIAGRAM A LOAD 1 AC -DC 4 TRIGGER * CIRCUIT +DC LOAD AC 3 2 B *Snubber option offered in 240 V version only. Load can be wired in location A or B A 1 LOAD AC AC 4 TRIGGER AC/DC CIRCUIT * CONVERTER AC LOAD 3 2 AC B *Snubber option offered in 240 V version only. Do not forget to visit us at: www.crydom.com Copyright 2021 Crydom Inc. Specifications subject to change without notice.