Product Information

FN5060-110-99

FN5060-110-99 electronic component of Schaffner

Datasheet
Power Line Filters 110A 55kW 0.069mH 33nF 3x500VAC

Manufacturer: Schaffner
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 1198.1546 ea
Line Total: USD 1198.15

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Tue. 28 May

MOQ : 1
Multiples : 1

Stock Image

FN5060-110-99
Schaffner

1 : USD 1039.1745
10 : USD 1039.1745
25 : USD 1035.8418
50 : USD 997.5762
100 : USD 959.4553
250 : USD 959.3588
500 : USD 959.2742

     
Manufacturer
Product Category
Category
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
FN510-12-29 electronic component of Schaffner FN510-12-29

Power Line Filters 12A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN510-24-33 electronic component of Schaffner FN510-24-33

Schaffner Power Line Filters 24A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN530-4-99 electronic component of Schaffner FN530-4-99

Power Line Filters 4A HI CURRENT TERM OUTPUT FLT-FRQ INVRT
Stock : 0

FN510-4-29 electronic component of Schaffner FN510-4-29

Schaffner Power Line Filters 4A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN510-8-29 electronic component of Schaffner FN510-8-29

Power Line Filters 8A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN510-33-33 electronic component of Schaffner FN510-33-33

Power Line Filters 33A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN530-12-99 electronic component of Schaffner FN530-12-99

Power Line Filters 12A HI CURRENT TERM OUTPUT FLT-FRQ INVRT
Stock : 4

FN510-16-29 electronic component of Schaffner FN510-16-29

Power Line Filters 16A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN510-66-34 electronic component of Schaffner FN510-66-34

Power Line Filters 66A SFTY TERM BLOCK OUTPUT FLT-FRQ INVRT
Stock : 0

FN530-16-99 electronic component of Schaffner FN530-16-99

Power Line Filters 16A HI CURRENT TERM OUTPUT FLT-FRQ INVRT
Stock : 0

Image Description
12-PMF-015-5-C electronic component of Api Technologies 12-PMF-015-5-C

Power Line Filters 15A PWR LINE FILTER
Stock : 0

FN3287-40-33-C21-R65 electronic component of Schaffner FN3287-40-33-C21-R65

Power Line Filters 3 Phase Slim Book Style Standard Line Filter 480VAC, 40A, STB Terminal 33, Cy 220nF
Stock : 0

FNC1610474472A electronic component of Kemet FNC1610474472A

Power Line Filters 1MHz .47uF
Stock : 0

FN3288HVIT-10-44-C26-R60 electronic component of Schaffner FN3288HVIT-10-44-C26-R60

Power Line Filters 3 Phase Slim Book Style High Performance IT Line Filter 690VAC, 10A, STB Terminal 44, Cy 1.5uF
Stock : 0

FN3288HVIT-50-53-C26-R60 electronic component of Schaffner FN3288HVIT-50-53-C26-R60

Power Line Filters 3 Phase Slim Book Style High Performance IT Line Filter 690VAC, 50A, STB Terminal 53, Cy 1.5uF
Stock : 0

FN3288HVIT-80-34-C26-R60 electronic component of Schaffner FN3288HVIT-80-34-C26-R60

Power Line Filters 3 Phase Slim Book Style High Performance IT Line Filter 690VAC, 80A, STB Terminal 34, Cy 1.5uF
Stock : 0

FN3288HVIT-63-53-C26-R60 electronic component of Schaffner FN3288HVIT-63-53-C26-R60

Power Line Filters 3 Phase Slim Book Style High Performance IT Line Filter 690VAC, 63A, STB Terminal 53, Cy 1.5uF
Stock : 0

FN3288-40-33-C17-R65 electronic component of Schaffner FN3288-40-33-C17-R65

Power Line Filters 3 Phase Slim Book Style High Performance Line Filter 480VAC, 40A, STB Terminal 33, Cy 47nF
Stock : 0

FN3288-40-33-C21-R65 electronic component of Schaffner FN3288-40-33-C21-R65

Power Line Filters 3 Phase Slim Book Style High Performance Line Filter 480VAC, 40A, STB Terminal 33, Cy 220nF
Stock : 3

FN3288-80-34-C17-R65 electronic component of Schaffner FN3288-80-34-C17-R65

Power Line Filters 3 Phase Slim Book Style High Performance Line Filter 480VAC, 80A, STB Terminal 34, Cy 47nF
Stock : 0

DATASHEET dv/dt filters FN 5060 Output Filter for Motor Drives Reduction of drive output voltage dv/dt Approvals Reduction of voltage stress at motor windings Protect AC motors from destructive effect of peak voltages Increase of motor service life UL recognized up to 700 A Improvement of system reliability Features and benefits Efficient reduction of high output voltage dv/dt from IGBT motor drives (as per IEC 60034-17/25) Restriction of overvoltages caused by line reflections on motor cables (as per IEC 60034-17/25) Performance indicators Protection of motor winding insulation from premature aging and destruction Increase service life of electric motors High reliability and production up time for mission critical applications Less interference propagation towards neighbouring equipment or lines Output filter with low impedance, ideal for processes requiring exceptional precision and reproducibility of movements Typical applications Technical specifications Motor drive applications with short to medium Nominal operating voltage 3x500 VAC motor cable length Rated operating voltage 3x550 VAC Machinery comprising servo or torque motors Rated currents 12 to 1100 A 40C Conveyers Motor frequency 0...60 Hz (with derating up to 120 Hz) HVAC equipment, incl. pumps, fans and Switching frequency 2...16 kHz, depending on motor cable length and compressors motor frequency -> refer graph on page 2 Elevators, hoisting and cranes Typical dv/dt reduction Factor 8 to 12 Motor drives for process lines Max. peak voltage 1000 V <3 V 50 Hz Voltage drop Applications where sine wave filters are not suited (e.g. high dynamic operation) Ambient temperature range -25C to +40C fully operational +40C to +100C with derating* -25C to +100C transport and storage Typical electrical schematic Overload capability 1.5 x rated current for 1 minute, ones per hour Protection category IP 00 UL 94V-2 Flammability corresponding to Design corresponding to UL 61800-5-1, EN 61800-5-1, EN 61558-2-20 or EN 60076-6 * I = I *((T T )/(T T )) = I *((100C-T )/60C) derated nominal max- amb max- nominal nom amb Typical electrical schematic (1100 A only)2 Output filters Schaffner Group Datasheets 11 Oct 2018 Filter selection table Filter Rated Typical motor Typical motor Nominal Nominal Typical Voltage Input/ Weight current drive drive inductance capacitance power drop**** Output 40C/50 Hz power rating power rating loss*** connections 400 V* 480 V** A kW kW mH nF W V kg FN 5060-12-84 12 5.5 6.6 0.095 4.7 53 0.4 -84 1 FN 5060-24-84 24 11 13.2 0.098 4.7 55 0.7 -84 1.6 FN 5060-30-99 30 15 18 0.254 33 143 2.4 -99 6.3 FN 5060-45-99 45 22 26.4 0.17 33 182 2.4 -99 6.3 FN 5060-60-99 60 30 36 0.127 33 189 2.4 -99 7.4 FN 5060-70-99 70 37 44.4 0.109 33 214 2.4 -99 8.6 FN 5060-90-99 90 45 52.8 0.085 33 254 2.4 -99 10.4 FN 5060-110-99 110 55 66 0.069 33 316 2.4 -99 11.5 FN 5060-150-99 150 75 90 0.051 68 449 2.4 -99 14.6 FN 5060-180-99 180 90 108 0.042 68 464 2.4 -99 18.0 FN 5060-250-99 250 132 158.4 0.031 68 508 2.4 -99 22.1 FN 5060-320-99 320 160 192 0.024 68 604 2.4 -99 29.6 FN 5060-400-99 400 200 240 0.019 68 637 2.4 -99 32.2 FN 5060-500-99 500 250 300 0.015 68 471 2.4 -99 54.5 FN 5060-600-99 600 315 378 0.013 100 437 2.5 -99 63.5 FN 5060-700-99 700 400 480 0.011 100 486 2.4 -99 74.0 FN 5060-900-99 900 500 600 0.008 100 597 2.3 -99 86.5 FN 5060-1100-99 1100 630 756 0.007 100 695 2.4 -99 114.0 * General purpose four-pole (1500 r/min) AC induction motor rated 400 V/50 Hz. ** General purpose four-pole (1500 r/min) AC induction motor rated 480 V/50 Hz. *** Power loss at 2 kHz switching frequency/80 m motor cable length. Exact value depends upon the motor cable type and length, switching frequency and further stray parameters within the system. **** Voltage drop at rated current and 50 Hz. Switching frequency vs. motor cable length Ensure the motor drive switching frequency is set to the required switching frequency (see filter selection table). Check the drives manual whether special settings are necessery. For any questions please contact the drives manufacturer. Refer also to the fPWM/cable length diagram below: Temperature monitoring function The temperature monitoring device opens a potential-free contact in the case of filter overtemperature (>180C). The maximum switching capability is 5 A/240 V. The switch can be used, for example, in the input of a CNC controller or as the trip of a circuit breaker in order to interrupt the mains power supply.

Tariff Desc

8543.70.00 - ELECTRICAL MACHINES AND APPARATUS, HAVING INDIVIDUAL FUNCTIONS, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER: Other machines and apparatus Free
91 .. Other
SCHAFFNER EMC
Schaffner EMC Inc
Schaffner EMC Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted