PM4H-W DIN48 SIZE ANALOG MULTI-LANGE PM4H-W CYCLIC TWIN TIMERS UL File No.: E122222 CSA File No.: LR39291 Features 1. A single twin timer unit that repeats (variable) ON/OFF. 48 1.890 2. Multiple ranges with a 0.1 s to 500 h time specification on a single unit. 3. The output ON/OFF operation is indicated by red and green LEDs. Its easy to check the operation at a glance. 4. The AC free power supply and shorter body make it easier to use. 62.5 5. A new screw terminal type has been added to the conventional pin type. 48 2.461 1.890 Wiring can be done easily with a screwdriver. mm inch 6. Compliant with UL, CSA, CE and LLOYD. RoHS Directive compatibility information PM4H-W Time range All types of PM4H-W timer have multi-time range. 16 time ranges are selectable. 1s to 500h (Max. range) is controlled. Time unit sec min hrs 10h Scale 1 0.1s to 1s 0.1 min to 1 min 0.1h to 1h 1.0h to 10h 5 0.5s to 5s 0.5 min to 5 min 0.5h to 5h 5h to 50h Control time range 10 1.0s to 10s 1.0 min to 10 min 1.0h to 10h 10h to 100h 50 5s to 50s 5 min to 50 min 5h to 50h 50h to 500h Product types Operating Protective Rated Operating Terminal Type Contact arrangement Time range Part number mode structure voltage type 8 pins PM4HW-H-AC240VW 100 to 240V AC Screw terminal PM4HW-H-AC240VSW 8 pins PM4HW-H-DC125VW 48 to 125V DC Screw terminal PM4HW-H-DC125VSW IP65 8 pins PM4HW-H-24VW 24V AC/DC Screw terminal PM4HW-H-24VSW 8 pins PM4HW-H-DC12VW 12V DC Cyclic Relay Screw terminal PM4HW-H-DC12VSW PM4H-W 16 selectable ranges (OFF-start, Timed-out Twin timer (1s to 500h) 8 pins PM4HW-H-AC240V Twin) 2 Form C 100 to 240V AC Screw terminal PM4HW-H-AC240VS 8 pins PM4HW-H-DC125V 48 to 125V DC Screw terminal PM4HW-H-DC125VS IP50 8 pins PM4HW-H-24V 24V AC/DC Screw terminal PM4HW-H-24VS 8 pins PM4HW-H-DC12V 12V DC Screw terminal PM4HW-H-DC12VS Terminal layouts and Wiring diagrams Pin Type Screw terminal type Cyclic timed-out relay contact: 2C Cyclic timed-out relay contact: 2C N.C. N.C. N.C. N.O. N.C. N.O. 6 7 8 9 10 N.O. N.O. 5 4 11 6 3 1 2 3 4 5 7 2 1 8 Operating Operating voltage (+) () voltage () (+) mm inch Dimensions Toletance: 0.5 .020 Screw terminal type: M3.5 Pin type 6.0 6.0 .236 .236 48 17.0 62.5 48 17.0 66.5 1.890 .670 1.890 .670 2.618 2.461 14.5 .571 48 44.5 48 44.5 1.890 1.752 1.890 1.752 Operation Power supply T1 T2 T1 Time-delay contact (N.O. contact) : Output OFF indicator (green) Time-delay contact (N.C. contact) : Output ON indicator (orange) T1: OFF set time Output ON-OFF indicator T2: ON set time All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. 41 1.614 41 1.614