Disc Ceramic Capacitors Safety Ceramic Capacitors ANTENNA: the capacitors are used to decouple the DEFINITIONS (IEC 384-14 1993) antenna leads of video and audio equipment, whose X FUNCTION: applications where the capacitor failure failure may lead to danger of electrical shock. does not lead to danger of electrical shock. There are TPC Safety Capacitors: three subclasses related to the peak voltage of the 61V (GZO): meets subclasses X1, Y1 Test voltage 4000 VAC impulses superimposed to the mains voltage: 62O (GKO): meets subclasses X1, Y2 Test voltage 2500 VAC Subclass X1: impulses up to 4000V 65N (GAY): meets subclasses X2, Y3 Test voltage 1800 VAC Subclass X2: impulses up to 2500V Subclass X3: impulses up to 1200V Y FUNCTION: applications where the capacitor failure may lead to danger of electrical shock. There are four subclasses related to the peak voltage of the impulses applied before the life test: Subclass Y1: impulses up to 8000V Subclass Y2: impulses up to 5000V Subclass Y3: rated 250Vac without impulses Subclass Y4: impulses up to 2500V HOW TO ORDER 61 V 101 K B D C A Product Code Voltage Capacitance Tolerance Lead Capacitor Finishing Packaging Forming Diameter PERFORMANCE CHARACTERISTICS 61V 62O 65N Measured at 1.0 kHz / 0.3 Vrms / 25C 1.0 kHz / 0.3 Vrms / 25C 1.0 kHz / 0.3 Vrms / 25C Capacitance Tolerance 20% / -20 +50% 20% / -20 +50% 20% / -20 +50% D.F max. 25C 1.5% 1.5% 1.5% Insulation Resistance (IR) 10 G 10 G 10 G Test Voltage Between Leads* 4.000 VAC 2.500 VAC 1.800 VAC Test Voltage Leads to Body 4.000 VAC 2.500 VAC 1.800 VAC Operating Temperature Range (C) -40 +125 -40 +125 -40 +125 * Main reference voltage CERTIFICATION BODY APPROVALS 61V 62O 65N Standard Certificate Rated Climatic Certificate Rated Climatic Certificate Rated Climatic Number Voltage Category Number Voltage Category Number Voltage Category UL UL 1414 E 147842 (N) 250 VAC E 147842 (N) 250 VAC E 147842 (N) 250 VAC CAS CAN/CSA - C22.2 No. 1-94 LR 100430-2 250 VAC LR 100430-1 250 VAC DIN BDE 0560 76830 400 VAC 25/85/21 Part 2 76804 VDE DIN EN 132400: 1995 94612 40/85/21/C X1: 400 VAC X1: 400 VAC 94610 101384 40/85/21/C Y1: 250 VAC Y1: 250 VAC IEC 384-14: 1993 94634 EN 132400: 1994 X1: 400 VAC X1: 400 VAC IMQ V4551 40/125/21/C V4635 40/125/21C IEC 384-14: 1993 Y1: 250 VAC Y2: 250 VAC 17Disc Ceramic Capacitors Safety Ceramic Capacitors Epoxy Coated CAPACITANCE VS. DISC DIAMETER Digits 1, 2, 3 of P.N. 61V 62O 65N C (pF) R 33 39 6.0 (0.236) 47 56 68 82 6.0 (0.236) 100 120 150 180 7.0 (0.276) 220 270 330 6.0 (0.236) 390 470 8.0 (0.315) 560 7.0 (0.276) 680 820 8.0 (0.315) 1000 7.0 (0.276) 8.0 (0.315) 1200 1500 10.0 (0.394) 1800 10.0 (0.394) 11.0 (0.433) 2200 9.0 (0.354) 2700 12.0 (0.472) 10.0 (0.394) 12.0 (0.472) 3300 14.0 (0.551) 3900 12.0 (0.472) 14.0 (0.551) 4700 16.0 (0.630) 8200 10000 19.0 (0.748) 16.0 (0.630) 16.0 (0.630) 20000 TEMPERATURE COEFFICIENT TYPICAL CURVES 18