ITE Grade FLS400 Watt AC-DC Power Supplies 400 Watt l 400 Watts Forced Cooled l Efficiency up to 90% l -40 to 70 degree operating temperature 3 l High power density : 23.70W/inch l Thermal Shut-Down feature / Dual fusing l 2.56m Hours, Telcordia -SR332-issue 3 MTBF The New FLS400 Series is designed to work with Forced air cooling. This is a highly efficient power supply that can deliver up to 400 W with air. This new series comes with two options. ie. Casing with Side Fan and Top Fan. 400 Watts 1 Model Number Description Voltage Max. Load Min. Load Ripple 5% with JST Connector FLS400-1312 12V 25A 0.0A with JST Connector 5% FLS400-1315 15V 20A 0.0A 2% with JST Connector FLS400-1324 24V 16.70A 0.0A with JST Connector 2% FLS400-1330 30V 13.30A 0.0A 2% with JST Connector FLS400-1348 48V 8.30A 0.0A with JST Connector 2% FLS400-1358 58V 6.90A 0.0A For Top FAN vesrion add TF Ex. FLS400-1324-TF For Side FAN version add SF Ex. FLS400-1324-SF Pin Connection PIN 1 AC LINE J1 (Input) PIN 2 NOT FITTED PIN 3 AC NEUTRAL PIN 1,2,3 V1 +VE J2 (Output) PIN 4,5,6 V1 -VE Earth Self clinching nut PIN 1 +VS (Remote Sense) (J9) PIN 2 -VS (Remote Sense) Signal Connector www.eospower.com 4EM-21-295 1 39-DE60-49855-002 / A ITE Grade FLS400 Watt AC-DC Power Supplies Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 2. Specifications are for nominal input voltage, 25C unless otherwise stated. 3. 400W with Forced cooling at 115 VAC to 264VAC. 4. Combine Output Power of Main Output, Fan supply should not exceed 400 W. 5. Output ripple can be more than 2 % of the output voltage. Input Characteristic Minimum Typical Maximum Units Notes & Conditions 85 VAC De-rate linearly from 100% at 115VAC to 70% at 85VAC Input Voltage 264 47 Hz 63 Input Frequency A Input Current 6.3 A 75 Inrush Current exceeds 0.95 at Full Load Power Factor Output Characteristic Minimum Typical Maximum Units Notes & Conditions 400 W Output Power At 230 VAC 8mS Hold-up Time +/-0.5% Line Regulation +/-0.5% Load Regulation +/-3% Output Voltage Adjustability ms 55 Rise Time +/-1% Set Point Tolerance > 105% Over Current Protection 110 to 140% Over Voltage Protection 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=4% , recovery time < 5 ms Transient Response General Characteristic Minimum Typical Maximum Units Notes & Conditions 90% At 230 VAC Efficiency 2.56m Hours Telcordia -SR332-issue 3 Mean Time Between Failure 4000 Isolation: Input to Output VDC ITAV 2500 Input to Ground Leakage Current 300 uA Typical www.eospower.com 4EM-21-295 2 39-DE60-49855-002 / A