NOW PART OF F-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part Handles High Current Battery Disconnect for Contingency Power The F-Series hydraulic-magnetic circuit breaker accommodates current ratings from 100 to 700 amps, as per agency approvals. An optional 25 millivolt metering shunt allows for safely monitoring current output. These breakers are available as a one to three pole configuration with maximum voltage ratings of 277VAC/125VDC and max IC of 50,000 amps. 1-3 100-700 277 125 Poles Amps VAC Max VDC Max Typical Applications Higher Amperage Battery Disconnect Systems Renewable Energy Applications Telecom Military www.carlingtech.com 860.793.9281 sales carlingtech.comTech Specs Mechanical Electrical Endurance 4000 ON-OFF operations with Maximum Voltage 125VDC, 277VAC rated Current & Voltage & 4000 Current Ratings Standard current coils: 100, 125, operations with no load (8000 150, 175, 225, 250 amps. 300, 350, operations total) 5 per minute. 400, 500, 600, 700 amps available Parallel Pole construction: 1000 operations with rated Current as parallel pole construction. and Voltage 5 per minute. Auxiliary Switch Rating SPDT 10.1 Amps 250VAC, 1.0 Trip Free All F-Series Circuit Breakers will Amps 65VDC, 0.5 Amps 80VDC 0.1 Amps 125VAC (with trip on overload, even when the gold contacts). actuator is forcibly held in the ON position. Insulation Resistance Minimum: 100 Megohms at 500 VDC Trip Indication The operating actuator moves positively to the OFF position Dielectric Strength 1960 VAC, 50/60 Hz for one minute when an overload causes the between all electrically isolated circuit breaker to trip. terminals, except 2500 VAC for one minute between alarm/aux. switch and main terminals with Physical contacts in open and closed Number of Poles 1-3 Poles position. F-Series circuit breakers comply with the 8mm spacing Note: Ratings over 250 Amps only available with parallel pole. & 3750VAC 50/60 Hz dielectric requirements from hazardous Internal Circuit Series (with or without auxiliary voltage to operator accessible Configuration switch), Switch Only (with or surfaces, between adjacent without auxiliary switch). poles and from main circuits to auxiliary circuits per Publications Available Accessories Factory installed: DC Current EN 60950 and VDE 0805. Metering Shunt (25 mV lr) Resistance, Impedance Values from Line to Load Terminal Weight Varies depending on - based on Series Trip Circuit construction. Consult factory. Breaker. Standard Colors Housing - Black Actuator- Black or White with contrasting ON-OFF RESISTANCE PER POLE VALUES 0.001 from Line to Load Terminals legend. (Values Based on Series Trip Circuit Breaker) CURRENT TOLERANCE Environmental (AMPS) (%) Designed and tested in accordance with requirements of 100 - 700 50 specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth O while carrying rated current per H Method 213, Test Condition I. 0.0001 M Instantaneous and ultra-short S curves tested 90% of rated current. Vibration Withstands 0.060 excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. 0.00001 Moisture Resistance Method 106D ten 24-hour cycles 100 700 + 25C to +65C, 80-98% RH.56 AMPRERE RATING days +85C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH 5% NaCl Solution, 96 hrs) Thermal Shock Method 107D, Condition A (Five cycles -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C 2. *Manufacturer reserves the right to change product specification without prior notice.