Product Information

ER14250W

Product Image X-ON

Datasheet
BATTERY, LITHIUM, WIRED, 1/2AA
Manufacturer: Battery



Price (Ex GST)

From 12.0582

58 - Global Stock
Ships to you between
Tue. 01 Feb to Mon. 07 Feb
MOQ: 1 Multiples:1
Pack Size :   1
Availability Price Quantity
58 - Global Stock


Ships to you between Tue. 01 Feb to Mon. 07 Feb

MOQ : 1
Multiples : 1

Stock Image

ER14250W
Battery

1 : $ 13.6631
25 : $ 12.6378
50 : $ 12.0582

     
Manufacturer
Battery
Product Category
Unclassified
Battery Technology
Lithium Thionyl Chloride
Battery Capacity
1.2Ah
Battery Voltage
3.6 V
Battery Size Code
1/2Aa
Battery Terminals
Wire Leads
External Diameter
14.5 mm
External Height
50.5 mm
External Width
-
External Depth
-
Weight
10 g
Battery Iec Code
Cr14250
Battery Neda Code
-
Product Range
-
Svhc
No Svhc (15 - Jun - 2015)
Approval Bodies
Ul
Body Diameter
17 mm
Discharge Current Max
40m A
External Length / Height
28.6 mm
Lead Diameter
75 mm
Operating Temperature Max
+ 85 C
Operating Temperature Min
- 60 C
Output Voltage
3.6 V
Storage Temperature Max
+ 120 C
Storage Temperature Min
- 55 C
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image ER34615
Consumer Battery & Photo Battery 3.6V 19Ah D-SIZE BOBBON CELL
Stock : 0
Stock Image ER14505P
BATTERY, LITHIUM, AA, 3.6V, AXIAL
Stock : 300
Stock Image ER145053FP
BATTERY, LITHIUM, 3.6V, AA, PCB
Stock : 0
Stock Image ER34615T
BATTERY, LITHIUM, 3.6V, D, TABS
Stock : 0
Stock Image ER14505W
BATTERY, LITHIUM, 3.6V, AA, WIRE
Stock : 0
Stock Image ER14505
Electronic Battery 3.6V 2.4Ah AA-SIZE BOBBIN CELL
Stock : 2478
Stock Image ER26500
Consumer Battery & Photo Battery 3.6V 9.0Ah C-SIZE BOBBIN CELL
Stock : 0
Stock Image ER14250
Electronic Battery 3.6V 1200mAh 1/2-AA BOBBIN CELL
Stock : 1099
Stock Image ER14505M
Consumer Battery & Photo Battery 3.6V 2000mAh AA-SIZE SPRIAL CELL
Stock : 0
Image Description
Stock Image AT45DB321D-SU
AT45DB321D-SU
Stock : 0
Stock Image 6190011511
ALU HI-TEMP ANTI-CORROSION 400ML
Stock : 0
Stock Image ER14250T EVE
BATTERY, LITHIUM, TAGGED, 1/2AA
Stock : 26
Stock Image 6190012000
LABEL REMOVER, AMBERSIL, 200ML
Stock : 192
Stock Image ER14250P
BATTERY, LITHIUM, 1/2AA, 3.6V, AXIAL
Stock : 80
Stock Image 6190015000
SILICONE LUBRICANT, 500ML
Stock : 0
Stock Image SS-6488-NF-A431
Conn Modular Jack F 8 POS 2.54mm Solder RA Thru-Hole 8 Terminal 1 Port
Stock : 1109
Stock Image MS27467T13F4PC
Conn MIL-DTL-38999 Circular M 4 POS ST Cable Mount 4 Terminal 1 Port
Stock : 0
Stock Image FFP33.5X12X6.5
Ferrite: one-piece; 28AWG; 30O; A:33.5mm; B:12mm; C:6.5mm; D:29mm
Stock : 0

Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68?BEL? 0.10 ER14250 0.31 ER32L65?1/10D? 0.25 ER14335 0.43 ER32L100?1/6D? 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615?LTC-3PN? 0.10 ER14250M 0.19 EF651620?LTC-5PN? 0.14 ER14335M 0.34 EF651625?LTC-7PN? 0.19 ER14505M 0.51 EF703228?LTC-16PN? 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 2/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 3. Composition/Information on Ingredient Material CAS# % wt. Lithium metal 7439-93-2 0.13~3.7 Thionyl Chloride electrolyte 7719-09-7 18~38 Carbon 1333-86-4 1.8~4.2 4. First-aid measures If ingredient leaked out from inside of a battery and if inhaled it, move to a place Inhalation where fresh air is provided. Refer for medical attention. If ingredient leaked out from inside of a battery and stuck on skin, wash the contact Skin contact areas off immediately with plenty of water and soap. If appropriate procedures are not taken, this may cause sores on the skin. Refer for medical attention. If ingredient leaked out from inside of a battery and came into eyes, flush the eyes with plenty of water for at least 15 minutes immediately without rubbing. Take a Eyes contact medical treatment. If appropriate procedures are not taken, this may cause an eye irritation. In case of swallowing of battery, immediately refer for medical attention. Swallowing 5. Fire-fighting Measures Fire extinguishing agent: Dry chemical, alcohol-resistant foam, powder, atomized water, carbon dioxide and dry sand are effective. Extinguishing method: Escape batteries to safe place prevent from ignition by spreading fire. Because of packing material of battery is paper, use water extinguisher, CO2 extinguisher or powder extinguisher as normal extinguisher. Since vapor, generated from burning batteries may make eyes, nose and throat irritate, be sure to extinguish the fire on the windward side. Wear the respiratory protection equipment in some cases. 6. Accidental Release Measures Chemical contents are sealed in metal can. But if the battery is mechanically or electrically abused, contents may leak out. In such case, take action as shown below. Personal precautions: Temporary inhalation of odor and attaching of electrolyte to skin does not cause serious health hazard. Be sure the ventilation and washing out of electrolyte quickly. Environmental precautions: Clean up it quickly. Specific environmental precaution is not necessary. Method and materials for containment and methods and materials for cleaning up: Contain and collect spillage and place in container for disposal according to local regulations. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 2/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 3. Composition/Information on Ingredient Material CAS# % wt. Lithium metal 7439-93-2 0.13~3.7 Thionyl Chloride electrolyte 7719-09-7 18~38 Carbon 1333-86-4 1.8~4.2 4. First-aid measures If ingredient leaked out from inside of a battery and if inhaled it, move to a place Inhalation where fresh air is provided. Refer for medical attention. If ingredient leaked out from inside of a battery and stuck on skin, wash the contact Skin contact areas off immediately with plenty of water and soap. If appropriate procedures are not taken, this may cause sores on the skin. Refer for medical attention. If ingredient leaked out from inside of a battery and came into eyes, flush the eyes with plenty of water for at least 15 minutes immediately without rubbing. Take a Eyes contact medical treatment. If appropriate procedures are not taken, this may cause an eye irritation. In case of swallowing of battery, immediately refer for medical attention. Swallowing 5. Fire-fighting Measures Fire extinguishing agent: Dry chemical, alcohol-resistant foam, powder, atomized water, carbon dioxide and dry sand are effective. Extinguishing method: Escape batteries to safe place prevent from ignition by spreading fire. Because of packing material of battery is paper, use water extinguisher, CO2 extinguisher or powder extinguisher as normal extinguisher. Since vapor, generated from burning batteries may make eyes, nose and throat irritate, be sure to extinguish the fire on the windward side. Wear the respiratory protection equipment in some cases. 6. Accidental Release Measures Chemical contents are sealed in metal can. But if the battery is mechanically or electrically abused, contents may leak out. In such case, take action as shown below. Personal precautions: Temporary inhalation of odor and attaching of electrolyte to skin does not cause serious health hazard. Be sure the ventilation and washing out of electrolyte quickly. Environmental precautions: Clean up it quickly. Specific environmental precaution is not necessary. Method and materials for containment and methods and materials for cleaning up: Contain and collect spillage and place in container for disposal according to local regulations. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 3/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 7. Handling and Storage Do not charge, short-circuit, disassemble, deform, heat above 100? or incinerate. Do not pile up or mingle battery with each other. Handing Do not place battery on metal case, metal plate or antistatic material. In case of multi cell application, replace all batteries to new at once when replacing used batteries. Be sure to store batteries in well-ventilated, dry and cool conditions. Keep away from water, rain, snow, frost or dew condensation. Do not store batteries near source of heat or nozzle of hot air. Storage Do not store batteries in direct sunshine. Take care not to get wet packing by dew condensation when packing is removed from cold to warm and humid condition. Enough number of fire fighting apparatuses should be installed in warehouse 8. Exposure Controls and Personal Protection There is no need of personal protective equipment on regular handling and storage. In the event, however, a large amount of electrolyte should be released by mechanical or electrical abuse, use the protection as shown below. Respiratory protection: Mask (with a filter preferably) Hand protection : Synthetic rubber gloves Eye protection : Goggles or glasses 9. Physical and Chemical Properties State?Solid Shape: Cylindrical?Prismatic 10. Stability and Reactivity Stability: Stable on regular handling Conditions to Avoid: External short circuit of battery, deformation by crush, exposure at high temperature of more than 100 degree C (may cause heat generation and ignition), direct sunlight, high humidity. Materials to avoid: Substances that cause short circuit. 11. Toxicological Information Inhalation, skin contact and eye contact are possible when the battery is opened. Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous membranes. Overexposure can cause symptoms of non-fibrotic lung injury and membrane irritation. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 2/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 3. Composition/Information on Ingredient Material CAS# % wt. Lithium metal 7439-93-2 0.13~3.7 Thionyl Chloride electrolyte 7719-09-7 18~38 Carbon 1333-86-4 1.8~4.2 4. First-aid measures If ingredient leaked out from inside of a battery and if inhaled it, move to a place Inhalation where fresh air is provided. Refer for medical attention. If ingredient leaked out from inside of a battery and stuck on skin, wash the contact Skin contact areas off immediately with plenty of water and soap. If appropriate procedures are not taken, this may cause sores on the skin. Refer for medical attention. If ingredient leaked out from inside of a battery and came into eyes, flush the eyes with plenty of water for at least 15 minutes immediately without rubbing. Take a Eyes contact medical treatment. If appropriate procedures are not taken, this may cause an eye irritation. In case of swallowing of battery, immediately refer for medical attention. Swallowing 5. Fire-fighting Measures Fire extinguishing agent: Dry chemical, alcohol-resistant foam, powder, atomized water, carbon dioxide and dry sand are effective. Extinguishing method: Escape batteries to safe place prevent from ignition by spreading fire. Because of packing material of battery is paper, use water extinguisher, CO2 extinguisher or powder extinguisher as normal extinguisher. Since vapor, generated from burning batteries may make eyes, nose and throat irritate, be sure to extinguish the fire on the windward side. Wear the respiratory protection equipment in some cases. 6. Accidental Release Measures Chemical contents are sealed in metal can. But if the battery is mechanically or electrically abused, contents may leak out. In such case, take action as shown below. Personal precautions: Temporary inhalation of odor and attaching of electrolyte to skin does not cause serious health hazard. Be sure the ventilation and washing out of electrolyte quickly. Environmental precautions: Clean up it quickly. Specific environmental precaution is not necessary. Method and materials for containment and methods and materials for cleaning up: Contain and collect spillage and place in container for disposal according to local regulations. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 1/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 MATERIAL SAFETY DATA SHEET 1. Product and Company Identification Product Category: Lithium-Thionyl Chloride (Li-SOCl ) Battery 2 Nominal Voltage: 3.6 V Product Name Type Lithium (gr.) Type Lithium (gr.) ER22G68(BEL) 0.10 ER14250 0.31 ER32L65(1/10D) 0.25 ER14335 0.43 ER32L100(1/6D) 0.44 ER14505 0.69 ER1860 0.07 ER17505 0.93 ER2450T 0.13 ER18505 0.98 EF651615(LTC-3PN) 0.10 ER14250M 0.19 EF651620(LTC-5PN) 0.14 ER14335M 0.34 EF651625(LTC-7PN) 0.19 ER14505M 0.51 EF703228(LTC-16PN) 0.41 ER17505M 0.72 ER18505M 0.90 Supplier?s Name: EVE Energy Co., Ltd Supplier?s Address: EVE Industrial Park, Xikeng Industrial Zone, Huihuan Town, Huizhou, Guangdong, China. Post Code: 516006 Emergency Telephone: (+86) -752-2606966 Fax: (+86) -752-2606033 Note: The battery is neither substance nor mixture but product and having no risk to life and health under normal use or transportation because ingredients of battery is not leaked out by virtue of hermetical sealing with metal case. This sheet notifies possible risk of our battery under abnormal use but mainly aim to provide information about ingredients, notification of handling and transportation regulations as a useful reference. 2. Hazards identification The important hazards and adverse effects of the No information available chemical product Chemical product ? specific No information available hazards Chemical contents are seal in metal can. Therefore, risk of exposure never occurs unless battery is mechanically or electrically abused. Outline of an anticipated Risk of explosion by fire is anticipated if batteries are dispose of in fire or heated emergency above 100 degree Celsius. Stacking or jumbling of batteries may cause external short circuits, heat generation, in some case, allowing fire or explosion. Note: our battery is not classified in accordance with the GHS classification. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 2/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 3. Composition/Information on Ingredient Material CAS# % wt. Lithium metal 7439-93-2 0.13~3.7 Thionyl Chloride electrolyte 7719-09-7 18~38 Carbon 1333-86-4 1.8~4.2 4. First-aid measures If ingredient leaked out from inside of a battery and if inhaled it, move to a place Inhalation where fresh air is provided. Refer for medical attention. If ingredient leaked out from inside of a battery and stuck on skin, wash the contact Skin contact areas off immediately with plenty of water and soap. If appropriate procedures are not taken, this may cause sores on the skin. Refer for medical attention. If ingredient leaked out from inside of a battery and came into eyes, flush the eyes with plenty of water for at least 15 minutes immediately without rubbing. Take a Eyes contact medical treatment. If appropriate procedures are not taken, this may cause an eye irritation. In case of swallowing of battery, immediately refer for medical attention. Swallowing 5. Fire-fighting Measures Fire extinguishing agent: Dry chemical, alcohol-resistant foam, powder, atomized water, carbon dioxide and dry sand are effective. Extinguishing method: Escape batteries to safe place prevent from ignition by spreading fire. Because of packing material of battery is paper, use water extinguisher, CO2 extinguisher or powder extinguisher as normal extinguisher. Since vapor, generated from burning batteries may make eyes, nose and throat irritate, be sure to extinguish the fire on the windward side. Wear the respiratory protection equipment in some cases. 6. Accidental Release Measures Chemical contents are sealed in metal can. But if the battery is mechanically or electrically abused, contents may leak out. In such case, take action as shown below. Personal precautions: Temporary inhalation of odor and attaching of electrolyte to skin does not cause serious health hazard. Be sure the ventilation and washing out of electrolyte quickly. Environmental precautions: Clean up it quickly. Specific environmental precaution is not necessary. Method and materials for containment and methods and materials for cleaning up: Contain and collect spillage and place in container for disposal according to local regulations. EVE Energy Co., Ltd Safety and Reliability Lab Lithium-Thionyl Chloride (Li-SOCl ) Battery 3/6 2 Document Number: RD-ER-201501-001 Issued date: 3 January 2015 7. Handling and Storage Do not charge, short-circuit, disassemble, deform, heat above 100? or incinerate. Do not pile up or mingle battery with each other. Handing Do not place battery on metal case, metal plate or antistatic material. In case of multi cell application, replace all batteries to new at once when replacing used batteries. Be sure to store batteries in well-ventilated, dry and cool conditions. Keep away from water, rain, snow, frost or dew condensation. Do not store batteries near source of heat or nozzle of hot air. Storage Do not store batteries in direct sunshine. Take care not to get wet packing by dew condensation when packing is removed from cold to warm and humid condition. Enough number of fire fighting apparatuses should be installed in warehouse 8. Exposure Controls and Personal Protection There is no need of personal protective equipment on regular handling and storage. In the event, however, a large amount of electrolyte should be released by mechanical or electrical abuse, use the protection as shown below. Respiratory protection: Mask (with a filter preferably) Hand protection : Synthetic rubber gloves Eye protection : Goggles or glasses 9. Physical and Chemical Properties State:Solid Shape: Cylindrical?Prismatic 10. Stability and Reactivity Stability: Stable on regular handling Conditions to Avoid: External short circuit of battery, deformation by crush, exposure at high temperature of more than 100 degree C (may cause heat generation and ignition), direct sunlight, high humidity. Materials to avoid: Substances that cause short circuit. 11. Toxicological Information Inhalation, skin contact and eye contact are possible when the battery is opened. Exposure to internal contents, the corrosive fumes will be very irritating to skin, eyes and mucous membranes. Overexposure can cause symptoms of non-fibrotic lung injury and membrane irritation. EVE Energy Co., Ltd Safety and Reliability Lab

Tariff Concession Code
Tariff Desc

Examine

Battery may also be referenced as

Battery