Product Information

TCM10000

TCM10000 electronic component of Red Lion

Datasheet
TRIAC CONVERTER MODULE, 0.1A; Current Ra; TRIAC CONVERTER MODULE, 0.1A; Current Rating:100mA; Product Range:-

Manufacturer: Red Lion
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 68.8969 ea
Line Total: USD 68.9

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1

Stock Image

TCM10000
Red Lion

1 : USD 68.3253

     
Manufacturer
Product Category
Brand
Current Rating
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
WF1000OK electronic component of Red Lion WF1000OK

KNURLED ALUMINUM 1 FT
Stock : 0

WM0400OF electronic component of Red Lion WM0400OF

FLAT POLYURETHANE 4/10 METER
Stock : 0

WM0400OK electronic component of Red Lion WM0400OK

KNURLED ALUMINUM 4/10 METER
Stock : 0

WF1000OF electronic component of Red Lion WF1000OF

FLAT POLYURETHANE 1 FT
Stock : 0

WI0006OF electronic component of Red Lion WI0006OF

ENCODER WHEEL, SHAFT MOUNT, 600RPM
Stock : 0

WF1000OR electronic component of Red Lion WF1000OR

ENCODER CODE WHEEL, 200PPR, 600RPM, 10KH; ENCODER CODE WHEEL, 200PPR, 600RPM, 10KHZ; Shaft Diameter:-; Circumference Max:-; Product Range:-
Stock : 24

VCM20000 electronic component of Red Lion VCM20000

VOLTAGE CONVERTER MODULE, 0.1A; Current; VOLTAGE CONVERTER MODULE, 0.1A; Current Rating:100mA; Product Range:-
Stock : 0

TORF1000 electronic component of Red Lion TORF1000

REPLACEMENT TIRE, 1FOOT, WHEEL; Product; REPLACEMENT TIRE, 1FOOT, WHEEL; Product Range:-
Stock : 0

WF1000BF electronic component of Red Lion WF1000BF

1 FT BALANCE POLY WHEEL; 1 FT BALANCE POLY WHEEL
Stock : 0

VT-MODEM-1WW electronic component of Red Lion VT-MODEM-1WW

RUGGED INDUSTRIAL TELEPHONE MODEM, 30V
Stock : 0

Image Description
CUB5PR00 electronic component of Red Lion CUB5PR00

PANEL DISPLAY, DC PROCESS, 10mA, 9V to 28V
Stock : 0

APM-M2-ANO electronic component of Trumeter APM-M2-ANO

ADVANCED PANEL METER, VOLT/AMP/FREQ
Stock : 0

OMD00000 electronic component of Red Lion OMD00000

RELAY MODULE; RELAY MODULE
Stock : 0

MDMV0100 electronic component of Red Lion MDMV0100

VOLTAGE METER
Stock : 0

XCENET00 electronic component of Red Lion XCENET00

ETHERNET OPT CARD, MODULAR CONTROLLER; C; ETHERNET OPT CARD, MODULAR CONTROLLER; Current Rating:-; Product Range:-
Stock : 0

NPA.47M50 electronic component of NTE NPA.47M50

Capacitance:0.47µF; Voltage Rating:50V;; Capacitance:0.47µF; Voltage Rating:50V; Product Range:NPA Series; Capacitance Tolerance:± 20%; Capacitor Terminals:Axial Leaded; Diameter:6mm; Lead Spacing:-; Height:15mm; Operating Temperature Min:-40C; ESR:-
Stock : 0

CUB4LP40 electronic component of Red Lion CUB4LP40

LOOP POWERED PROCESS METER
Stock : 6

LMPCC000 electronic component of Red Lion LMPCC000

LOGIC MAGNETIC PICKUP, 9-30VDC, NPN
Stock : 0

AFCM0000 electronic component of Red Lion AFCM0000

SIGNAL CONVERTER
Stock : 0

PAXR0020 electronic component of Red Lion PAXR0020

DIGITAL METER, 14.2MM, 36VDC, 6 DIGIT
Stock : 11

Bulletin No. VCM-A Drawing No. LP0646 Released 02/10 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CONVERTER MODULES ADAPTS MANY RED LION CONTROLS COUNTERS AND ACCESSORIES TO A WIDE RANGE OF SIGNAL SOURCES VCM - VOLTAGE CONVERTER MODULES Converts AC/DC voltages to an acceptable signal input for many RLC counters and accessories and provides input/output voltage isolation. TCM - TRIAC CONVERTER MODULE Accepts unloaded, high off-state leakage triac output from sensors and programmable controllers. LCM - LOGIC CONVERTER MODULE Interfaces with CMOS, TTL, and other logic circuits up to +28 VDC, at speeds to 50 KHz. Allows Cub Counters to share sensor outputs with other series counters. These miniature sized modules are completely encapsulated in PVC, which provides protection against oil, water, dirt, and mechanical damage. They can be quickly and easily mounted to most surfaces by using the self-stick adhesive pad. VCM - VOLTAGE CONVERTER MODULES SPECIFICATIONS These modules provide a convenient way to adapt RLC Counters to most any 1. INPUT: VCM1 = 4 to 50 VAC/DC, 50/60 Hz machine control voltage signal. They also make it easy to upgrade electro- VCM2 = 50 to 270 VAC/DC, 50/60 Hz mechanical counter installations with RLC Counters. 2. OUTPUT: Solid state DC contact closure VCMs are available in two input voltage ranges that cover the spectrum Output rating: 30 VDC at 100 mA max from 4-270 V. The non-polarized input of these modules will accept A.C. (50/60 Output Isolation: 2300 V RMS Hz) or D.C. voltages at input cycles up to 30 Hz. The output uses MOSFET Off State Leakage: 1 A max technology that is compatible with either the L.S. Count or Remote Reset inputs 3. FREQUENCY: Max output frequency 20 Hz of RLC Counters. Electrical isolation between input and output is achieved by 4. ENVIRONMENT: 0-50 C means of an internal opto-isolator rated at 2300 VRMS. DIMENSIONS FOR VCM, TCM, & LCM In inches (mm) (SEE ORDERING INFORMATION FOR WIRE COLOR) 1.12 (28.5) 0.71 (18) INPUT LEADS: 6 (150mm) Long, 22GA. VCM BLACK 1.52 (38.5) and TCM Leads have 600V Insulation. LCM has OUTPUT LEADS: 6 (150mm) Long 3 Leads with 300V Insulation. (For color codes 22GA Stranded, 300V Insulation see specific model.) 0.45 (11.5) SELF STICK ADHESIVE PAD 1 OUTPUT INPUTTCM - TRIAC CONVERTER MODULE SPECIFICATIONS The TCM is a specialized version of the VCM. It is specifically designed to 1. INPUT: 115 VAC 10% (50/60 Hz) 10 mA max current draw operate with photo-electric sensors and programmable controllers that have 115 2. FREQUENCY: 10 Hz max output VAC Triac outputs. Due to protective suppression circuits connected in parallel 3. OUTPUT: Solid state DC contact closure with Triacs, these outputs have a high OFF-State Leakage current, which, if Output rating: 30 VDC at 100 mA unloaded, is sufficient to keep a VCM in the ON condition continuously. Output Isolation: 2300 V RMS The TCM incorporates a current bias that offsets output leakage currents Off State Leakage: 1 A max up to 4 mA and allows the application of RLC Counters to most unloaded 4. ENVIRONMENT: 0-50 C Triac outputs. These modules are available for operation with 115 VAC 10% 50/60 Hz only. They operate at count rates up to 10 cps, and also provide input/output electrical isolation. Connections for the TCM are the same as those for the VCM. Note: VCMs can be used with Triac outputs that are also driving substantial loads, since the load will shunt the leakage current away from the VCM input. TYPICAL CONNECTION EXAMPLE FOR VCM & TCM (Shown with optional VCM for Control Voltage Remote Reset) Consult Connections and Configurations set up information in counter instruction literature for wiring. Reference switch and contact input information. EXISTING CONTACT USED TO OPERATE RELAY RLC COUNTER SEE ORDERING INFORMATION FOR WIRE COLOR MACHINE COUNT RELAY ORANGE CONTROL COIL RESET VOLTAGE COUNT VCM/TCM COMMON BLACK ORANGE RESET CONTACT SEE ORDERING INFORMATION MACHINE FOR WIRE COLOR ORANGE CONTROL VOLTAGE REMOTE RESET BLACK ORANGE VCM/TCM LCM - CONVERTER MODULE SPECIFICATIONS The LCM adapts CUB* Counters to practically any type of logic and sensor 1. POWER: 5 to 28 VDC, 8 mA max output, and to any count signal voltage from +3 to +28 VDC. The module 2. INPUT: V = +2.5 to 28 VDC, 500 A max source IH accepts input count pulses from NPN Open-Collector Transistor outputs, V = +1.0 VDC, 50 A max sink IL Bi-Polar outputs, or sourcing outputs such as Emitter-Follower or PNP Open- 3. OUTPUT: Bipolar 3 VDC with 1 mA sink/source (output should not be Collector Transistors (Sourcing outputs must be externally loaded with a load of connected to voltage levels above 3.5 VDC) 10 Kohms or less). The LCM output is a Bi-Polar drive that is compatible with 4. FREQUENCY: MAX input/output frequency = 50 KHz (see counter input either the Low-Speed or High-Speed Counter inputs as well as the Remote for frequency limitations) Reset input** of the CUB Counters. The output is inverted with respect to the 5. ENVIRONMENT: 0-50 C input which causes the CUB Counter to increment on the leading (positive going) edge of a count pulse. Power for operation of the LCM can be normally obtained from the existing D.C. power supply used to operate the sensor or other ALTERNATE CONNECTION logic circuitry. When count pulse signals are generated by switch contacts the FOR SWITCH CONTACT TO EXT. D.C. INPUT (SEE TEXT) LCM output can be applied to the L.S. input of the CUB to de-bounce these SUPPLY +5 TO 28VDC, 8mA pulses. Minimum pulse width when driving the L.S. input is 10 msec and CUB CONTROLLER INPUT COUNT maximum count rate is 50 cps. WHITE PULSE BLUE H.S. CNT. V = 2.5 TO 28VDC IH L.S. CNT. OR V = +1.0V * LCM intended for use with CUB1,2,3,and 7. IL REM. RST. BLK ** When used to operate Remote Reset input, the LCM will reset counter when RST. EN. BLACK COMMON COMMON input to LCM goes high due to signal inversion. 2 OUTPUT OUTPUT INPUT INPUT OUTPUT INPUT

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted