TGP2102 35 GHz 5-Bit Digital Phase Shifter Product Description Qorvos TGP2102 is a 5-bit digital phase shifter MMIC design using Qorvos proven 0.25 m power pHEMT process to support a variety of Ka-Band phased array applications including military radar. The 5-bit design utilizes a compact topology that achieves 2 a 1.41mm die area and high performance. The TGP2102 provides a 5-bit digital phase shift function with a nominal 7dB insertion loss and 5 RMS phase shift error over a bandwidth of 3237GHz. Product Features The TGP2102 requires a minimum of off-chip components Frequency Range: 32 to 37 GHz and operates with a -5V control voltage. Each device is RF 5-Bit Digital Phase Shifter tested on-wafer to ensure performance compliance. The RMS Phase Error: 3.5 35 GHz device is available in chip form. RMS Amplitude Error: 0.4 dB 35 GHz The device is lead-free and RoHS compliant. Insertion Loss: 7 dB Return Loss: 14 dB IRL 7 dB ORL Negative Control Voltage: -5/0 V Single-Ended logic CMOS Compatible Chip Dimensions: 1.88 x 0.75 x 0.10 mm Performance is typical across frequency. Please reference electrical specification table and data plots Functional Block Diagram for more details IN OUT 0 0 0 0 0 11.25 180 90 45 22.5 2 1 Applications 3 7 6 5 4 8 Military Radar Transit / Receive Massive MIMO Ordering Information Part No. Description 32-37 GHz 5 Bit Digital Phase Shifter, TGP2102 Waffle Pack 25 pieces - 1 of 9 - Datasheet Rev. B. Jan. 29, 2021 Subject to change without notice www.qorvo.com TGP2102 35 GHz 5-Bit Digital Phase Shifter Absolute Maximum Ratings Recommended Operating Conditions Parameter Value Parameter Value Control Voltage (V ) -5/0 V C Control and Supply Voltages -8 V Reference Voltage (VSUPPLY) -5 V Control Current 1 mA Operating Temperature Range -40 to +85 C Power Dissipation 0.1 W Electrical specifications are measured at specified test Input Power, CW 20 dBm conditions. Specifications are not guaranteed overall Channel Temperature 150 C operating conditions. Mounting Temperature (30 Seconds) 320 C Storage Temperature -65 to 150 C Operation of this device outside the parameter ranges given above may cause permanent damage. These are stress ratings only, and functional operation of the device at these conditions is not implied. Extended application of Absolute Maximum Rating conditions may reduce device reliability. Electrical Specifications Test conditions unless otherwise noted: 25C. VSUPPLY = -5 V, VC = -5/0 V see State Table. Parameter Min Typical Max Units Operational Frequency Range 32 37 GHz Insertion Loss 7 dB Input Return Loss 14 dB Output Return Loss 7 dB Peak Phase Shift Error 5 deg RMS Phase Shift Error 4 deg Peak Amplitude Error 1 dB RMS Amplitude Error 0.7 dB Notes: The data are from the typical devices as determined by fixtured measurements. - 2 of 9 - Datasheet Rev. B. Jan. 29, 2021 Subject to change without notice www.qorvo.com