Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(? 30mV / ? 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]AXICOM
Telecom-, Signal and RF Relays 108-98003 Rev. G
FX2 Relay
Coil Operating Range
Unom = Nominal coil voltage
80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
3.2 the coil voltage (limiting voltage)
AXICOM
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Telecom-, Signal and RF Relays 108-98003 Rev. G
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
FX2 Relay
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
Coil Operating Range
1.4
1.2
1
Unom. nominal coil voltage
Signal Relays
AXICOM
0.8
Unom = Nominal coil voltage
0.6 80 mW
Uop. min.
140 mW
0.4 Umax. = Upper limit of the operative range of
3.4 Urel. min. 200 mW
0.2
the coil voltage (limiting voltage)
3.2
FX2 Relay (Continued)
0
Umax. at 0 A
3
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
Ambient Temperature [?C]
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
2.4 For latching relays Uset min. resp. Ureset min.
2.2
Coil Data (continued) Urel. min. = InsulationLower limit of the operative range of standar d* high dielectric*
2
Initial dielectric strength
the coil voltage (reliable release voltage)
1.8
260 mW
between open contacts 1800V 2100V
1.6 rms rms
2.6 300 mW
1.4 between contact and coil 1800V 4000V
rms rms
2.4
1.2
between adjacent contacts 1800V 2100V
rms rms
Umax. at 0 A
2.12
Unom. nominal coil voltage
Umax. at 2 x 1 A Initial surge withstand voltage
0.8
2.0
Umax. at 2 x 2 A
between open contacts 2500V 2900V
0.6
Uop. min.
1.8
0.4
between contact and coil 3500V 6000V
Urel. min.
0.2
1.6
between adjacent contacts 2500V 2900V
0
1.4
Initial insulation resistance
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
9 9
1.2
Ambient Temperature [?C] between insulated elements >10? >10 ?
1.0
Capacitance
Unom. nominal coil voltage
0.8
between open contacts max. 4pF
0.6 between contact and coil max. 2pF
Uop. min.
0.4 between adjacent contacts max. 2pF
260 mW
Urel. min.
2.6 300 mW
Cross talk at 100MHz/900MHz -34.0dB/-15.1dB
0.2
2.4
Insertion loss at 100MHz/900MHz 0.03dB/0.60dB
0.0
Umax. at 0 A
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
2.2 Voltage standing wave ratio (VSWR)
Umax. at 2 x 1 A
Ambient Temperature [?C]
2.0 at 100MHz/900MHz 1.07/1.45
Umax. at 2 x 2 A
Coil versions, bistable 1 coil
1.8
*this relay contains SF6 (Sulfur hexafluoride, CAS number: 2551-62-4) for dielectric strength
Coil Rated Set Limiting Reset Coil Rated coil
1.6
enhancement, SF6 is hermetically sealed in relay without leaks to air during normal applica-
code voltage voltage voltage voltage resistance power
1.4 tion as recommended per the applicable product specification. It is clarified that the usage
4.4
VDC VDC VDC VDC100 mW Latching ??10% mW
of SF6 in mini signal relay is not prohibited by related regulations. Please contact TE local
1.2
4.2
sales or field engineer for further information and detailed material declaration.
Standard, bistable 1 coil
4
1.0
3.8
41 U3nom . nominal coil voltage2.25 7.50 -2.25 90 100
0.8
3.6
42 4.5 3.38 11.20 -3.38 203 100
3.4
0.6
3.2
43 5 3.75 12.40 -3.75U op. min. 250 100 Other Data
0.4
3
Urel. min.
44 6 4.50 14.90 -4.50 360 100 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
2.8
0.2
2.6
45 9 6.75 22.40 -6.75 810 100 refer to the Product Compliance Support Center at
0.0
2.4
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
46 12 9.00 29.80 -9.00 1440 100 www.te.com/customersupport/rohssupportcenter
2.2
2
47 U24max. - 100 % coil duty at 0 18.00Ambient Temperature [?C] 48.70A -18.00 3840 150 Ambient temperature -40?C to +85?C
1.8
Umax. - 5 % coil duty at 2 x 2 A
High dielectric version, bistable 1 coil Category of environmental protection
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
62 4.5 3.15 11.20 -3.15 203 100 IEC 61810 RT V - immersion cleanable
1.2 Umax. - 5 % coil duty at 0 A
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Degree of protection, IEC 60529 IP 67, immersion cleanable
1
Unom. nominal coil voltage
4.0.48 Vibration resistance (functional) 20g, 10 to 500Hz
100 mW Latching
4.0.62
Shock resistance (functional), half sinus 11ms 50g
0.44
Uset min.
0.2 Shock resistance (destructive), half sinus 0.5ms 1500g
3.8
0
3.6
Weight max. 2.5g
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
3.4
Ambient Temperature [?C] Resistance to soldering heat THT Peek value
3.2
3
IEC 60068-2-20 265?C/10s
2.8
Ultrasonic cleaning not recommended
2.6
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
2.4
Packaging/unit tube/50 pcs., box/1000 pcs.
2.2
2
Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
Other coil voltages on request.
U upper limit of the operative range of the coil voltage (limiting voltage) when coils are
max
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
continuously energized
U lower limit of the operative range of the coil voltage (reliable operate voltage)
op min
U lower limit of the operative range of the coil voltage (reliable release voltage)
rel min
Terminal assignment
TOP view on component side of PCB PCB layout
TOP view on component side of PCB
Monostable Bistable, 1 coil
Contacts are shown in reset
condition.
Both coils can be used as
either set or reset coils.
Contact position might
change during transportation
and must be reset before
use.
2
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]AXICOM
Telecom-, Signal and RF Relays 108-98003 Rev. G
FX2 Relay
Coil Operating Range
Unom = Nominal coil voltage
80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
3.2 the coil voltage (limiting voltage)
AXICOM
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Telecom-, Signal and RF Relays 108-98003 Rev. G
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
FX2 Relay
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
Coil Operating Range
1.4
1.2
1
Unom. nominal coil voltage
Signal Relays
AXICOM
0.8
Unom = Nominal coil voltage
0.6 80 mW
Uop. min.
140 mW
0.4 Umax. = Upper limit of the operative range of
3.4 Urel. min. 200 mW
0.2
the coil voltage (limiting voltage)
3.2
FX2 Relay (Continued)
0
Umax. at 0 A
3
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
Ambient Temperature [?C]
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
2.4 For latching relays Uset min. resp. Ureset min.
2.2
Coil Data (continued) Urel. min. = InsulationLower limit of the operative range of standar d* high dielectric*
2
Initial dielectric strength
the coil voltage (reliable release voltage)
1.8
260 mW
between open contacts 1800V 2100V
1.6 rms rms
2.6 300 mW
1.4 between contact and coil 1800V 4000V
rms rms
2.4
1.2
between adjacent contacts 1800V 2100V
rms rms
Umax. at 0 A
2.12
Unom. nominal coil voltage
Umax. at 2 x 1 A Initial surge withstand voltage
0.8
2.0
Umax. at 2 x 2 A
between open contacts 2500V 2900V
0.6
Uop. min.
1.8
0.4
between contact and coil 3500V 6000V
Urel. min.
0.2
1.6
between adjacent contacts 2500V 2900V
0
1.4
Initial insulation resistance
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
9 9
1.2
Ambient Temperature [?C] between insulated elements >10? >10 ?
1.0
Capacitance
Unom. nominal coil voltage
0.8
between open contacts max. 4pF
0.6 between contact and coil max. 2pF
Uop. min.
0.4 between adjacent contacts max. 2pF
260 mW
Urel. min.
2.6 300 mW
Cross talk at 100MHz/900MHz -34.0dB/-15.1dB
0.2
2.4
Insertion loss at 100MHz/900MHz 0.03dB/0.60dB
0.0
Umax. at 0 A
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
2.2 Voltage standing wave ratio (VSWR)
Umax. at 2 x 1 A
Ambient Temperature [?C]
2.0 at 100MHz/900MHz 1.07/1.45
Umax. at 2 x 2 A
Coil versions, bistable 1 coil
1.8
*this relay contains SF6 (Sulfur hexafluoride, CAS number: 2551-62-4) for dielectric strength
Coil Rated Set Limiting Reset Coil Rated coil
1.6
enhancement, SF6 is hermetically sealed in relay without leaks to air during normal applica-
code voltage voltage voltage voltage resistance power
1.4 tion as recommended per the applicable product specification. It is clarified that the usage
4.4
VDC VDC VDC VDC100 mW Latching ??10% mW
of SF6 in mini signal relay is not prohibited by related regulations. Please contact TE local
1.2
4.2
sales or field engineer for further information and detailed material declaration.
Standard, bistable 1 coil
4
1.0
3.8
41 U3nom . nominal coil voltage2.25 7.50 -2.25 90 100
0.8
3.6
42 4.5 3.38 11.20 -3.38 203 100
3.4
0.6
3.2
43 5 3.75 12.40 -3.75U op. min. 250 100 Other Data
0.4
3
Urel. min.
44 6 4.50 14.90 -4.50 360 100 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
2.8
0.2
2.6
45 9 6.75 22.40 -6.75 810 100 refer to the Product Compliance Support Center at
0.0
2.4
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
46 12 9.00 29.80 -9.00 1440 100 www.te.com/customersupport/rohssupportcenter
2.2
2
47 U24max. - 100 % coil duty at 0 18.00Ambient Temperature [?C] 48.70A -18.00 3840 150 Ambient temperature -40?C to +85?C
1.8
Umax. - 5 % coil duty at 2 x 2 A
High dielectric version, bistable 1 coil Category of environmental protection
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
62 4.5 3.15 11.20 -3.15 203 100 IEC 61810 RT V - immersion cleanable
1.2 Umax. - 5 % coil duty at 0 A
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Degree of protection, IEC 60529 IP 67, immersion cleanable
1
Unom. nominal coil voltage
4.0.48 Vibration resistance (functional) 20g, 10 to 500Hz
100 mW Latching
4.0.62
Shock resistance (functional), half sinus 11ms 50g
0.44
Uset min.
0.2 Shock resistance (destructive), half sinus 0.5ms 1500g
3.8
0
3.6
Weight max. 2.5g
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
3.4
Ambient Temperature [?C] Resistance to soldering heat THT Peek value
3.2
3
IEC 60068-2-20 265?C/10s
2.8
Ultrasonic cleaning not recommended
2.6
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
2.4
Packaging/unit tube/50 pcs., box/1000 pcs.
2.2
2
Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
Other coil voltages on request.
U upper limit of the operative range of the coil voltage (limiting voltage) when coils are
max
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
continuously energized
U lower limit of the operative range of the coil voltage (reliable operate voltage)
op min
U lower limit of the operative range of the coil voltage (reliable release voltage)
rel min
Terminal assignment
TOP view on component side of PCB PCB layout
TOP view on component side of PCB
Monostable Bistable, 1 coil
Contacts are shown in reset
condition.
Both coils can be used as
either set or reset coils.
Contact position might
change during transportation
and must be reset before
use.
2
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay (Continued)
Dimensions Packing
14.95?0.05 7.3?0.05
0.5
5.08?0.15
Product code structure Typical product code D32 04
Type
D32 Signal Relays FX2
2 form C, 2 CO
Coil
Coil code: please refer to coil versions table
Performance and coil type
0x,1x Standard version, monostable
2x High sensitive version, monostable
4x Standard version bistable
9x High dielectric version, monostable
6x High dielectric version, bistable
Product code Arrangement Perf. type Coil type Coil Part number
D3206 2 form C (2 CO) Standard Monostable 3VDC 1462034-6
D3207 4VDC 1462034-8
D3204 4.5VDC 1462034-2
D3209 5VDC 1462034-9
D3205 6VDC 1462034-5
D3210 9VDC 1-1462034-3
D3202 12VDC 1462034-1
D3212 24VDC 1-1462034-4
D3213 48VDC 1-1462034-5
D3221 2 form C (2 CO) High sensitive Monostable 3VDC 1-1462034-9
D3222 4.5VDC 2-1462034-0
D3223 5VDC 2-1462034-1
D3225 9VDC 2-1462034-3
D3226 12VDC 2-1462034-4
D3227 24VDC 2-1462034-5
D3228 48VDC 2-1462034-6
D3241 2 form C (2 CO) Standard Bistable 3VDC 2-1462034-8
D3242 4.5VDC 2-1462034-9
D3243 5VDC 3-1462034-0
D3246 12VDC 3-1462034-3
D3247 24VDC 3-1462034-4
D3291 2 form C (2 CO) High dielectric Monostable 3VDC 6-1462034-6
D3292 4.5VDC 6-1462034-8
D3296 12VDC 6-1462034-7
D3262 2 form C (2 CO) High dielectric Bistable 4.5VDC 6-1462034-3
This list represents the most common types and does not show all variants covered by this data sheet.
Other types on request
3
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
0.3?0.05
3.3?0.3 10.7?0.05Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]AXICOM
Telecom-, Signal and RF Relays 108-98003 Rev. G
FX2 Relay
Coil Operating Range
Unom = Nominal coil voltage
80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
3.2 the coil voltage (limiting voltage)
AXICOM
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Telecom-, Signal and RF Relays 108-98003 Rev. G
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
FX2 Relay
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
Coil Operating Range
1.4
1.2
1
Unom. nominal coil voltage
Signal Relays
AXICOM
0.8
Unom = Nominal coil voltage
0.6 80 mW
Uop. min.
140 mW
0.4 Umax. = Upper limit of the operative range of
3.4 Urel. min. 200 mW
0.2
the coil voltage (limiting voltage)
3.2
FX2 Relay (Continued)
0
Umax. at 0 A
3
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
Ambient Temperature [?C]
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
2.4 For latching relays Uset min. resp. Ureset min.
2.2
Coil Data (continued) Urel. min. = InsulationLower limit of the operative range of standar d* high dielectric*
2
Initial dielectric strength
the coil voltage (reliable release voltage)
1.8
260 mW
between open contacts 1800V 2100V
1.6 rms rms
2.6 300 mW
1.4 between contact and coil 1800V 4000V
rms rms
2.4
1.2
between adjacent contacts 1800V 2100V
rms rms
Umax. at 0 A
2.12
Unom. nominal coil voltage
Umax. at 2 x 1 A Initial surge withstand voltage
0.8
2.0
Umax. at 2 x 2 A
between open contacts 2500V 2900V
0.6
Uop. min.
1.8
0.4
between contact and coil 3500V 6000V
Urel. min.
0.2
1.6
between adjacent contacts 2500V 2900V
0
1.4
Initial insulation resistance
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
9 9
1.2
Ambient Temperature [?C] between insulated elements >10? >10 ?
1.0
Capacitance
Unom. nominal coil voltage
0.8
between open contacts max. 4pF
0.6 between contact and coil max. 2pF
Uop. min.
0.4 between adjacent contacts max. 2pF
260 mW
Urel. min.
2.6 300 mW
Cross talk at 100MHz/900MHz -34.0dB/-15.1dB
0.2
2.4
Insertion loss at 100MHz/900MHz 0.03dB/0.60dB
0.0
Umax. at 0 A
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
2.2 Voltage standing wave ratio (VSWR)
Umax. at 2 x 1 A
Ambient Temperature [?C]
2.0 at 100MHz/900MHz 1.07/1.45
Umax. at 2 x 2 A
Coil versions, bistable 1 coil
1.8
*this relay contains SF6 (Sulfur hexafluoride, CAS number: 2551-62-4) for dielectric strength
Coil Rated Set Limiting Reset Coil Rated coil
1.6
enhancement, SF6 is hermetically sealed in relay without leaks to air during normal applica-
code voltage voltage voltage voltage resistance power
1.4 tion as recommended per the applicable product specification. It is clarified that the usage
4.4
VDC VDC VDC VDC100 mW Latching ??10% mW
of SF6 in mini signal relay is not prohibited by related regulations. Please contact TE local
1.2
4.2
sales or field engineer for further information and detailed material declaration.
Standard, bistable 1 coil
4
1.0
3.8
41 U3nom . nominal coil voltage2.25 7.50 -2.25 90 100
0.8
3.6
42 4.5 3.38 11.20 -3.38 203 100
3.4
0.6
3.2
43 5 3.75 12.40 -3.75U op. min. 250 100 Other Data
0.4
3
Urel. min.
44 6 4.50 14.90 -4.50 360 100 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
2.8
0.2
2.6
45 9 6.75 22.40 -6.75 810 100 refer to the Product Compliance Support Center at
0.0
2.4
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
46 12 9.00 29.80 -9.00 1440 100 www.te.com/customersupport/rohssupportcenter
2.2
2
47 U24max. - 100 % coil duty at 0 18.00Ambient Temperature [?C] 48.70A -18.00 3840 150 Ambient temperature -40?C to +85?C
1.8
Umax. - 5 % coil duty at 2 x 2 A
High dielectric version, bistable 1 coil Category of environmental protection
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
62 4.5 3.15 11.20 -3.15 203 100 IEC 61810 RT V - immersion cleanable
1.2 Umax. - 5 % coil duty at 0 A
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Degree of protection, IEC 60529 IP 67, immersion cleanable
1
Unom. nominal coil voltage
4.0.48 Vibration resistance (functional) 20g, 10 to 500Hz
100 mW Latching
4.0.62
Shock resistance (functional), half sinus 11ms 50g
0.44
Uset min.
0.2 Shock resistance (destructive), half sinus 0.5ms 1500g
3.8
0
3.6
Weight max. 2.5g
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
3.4
Ambient Temperature [?C] Resistance to soldering heat THT Peek value
3.2
3
IEC 60068-2-20 265?C/10s
2.8
Ultrasonic cleaning not recommended
2.6
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
2.4
Packaging/unit tube/50 pcs., box/1000 pcs.
2.2
2
Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
Other coil voltages on request.
U upper limit of the operative range of the coil voltage (limiting voltage) when coils are
max
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
continuously energized
U lower limit of the operative range of the coil voltage (reliable operate voltage)
op min
U lower limit of the operative range of the coil voltage (reliable release voltage)
rel min
Terminal assignment
TOP view on component side of PCB PCB layout
TOP view on component side of PCB
Monostable Bistable, 1 coil
Contacts are shown in reset
condition.
Both coils can be used as
either set or reset coils.
Contact position might
change during transportation
and must be reset before
use.
2
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay
n
Slim line 15x7.3mm (.590x.287?)
n
2 form C bifurcated contacts (2 CO), switching current 2A
n
High sensitivity for low power consumption, 80mW/140mW
n
High dielectric characteristic, up to 2100Vrms between open
contact
n
High surge capability (1.2/50?s and 10/700?s) meets Telcordia GR
1089 and FCC Part 68, up to 2900V between open contacts,
up to 6000V between coil and contacts
n
High mechanical shock, up to 1500g survival
n
Hermetically sealed (RT V)
Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
Z
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
Coil Data
Magnetic system polarized, monostable, bistable
Approvals Coil voltage range 3 to 48VDC
UL 508 File No. E 111441 Max. coil temperature 125?C.
Technical data of approved types on request
Thermal resistance <165K/W
Contact Data Coil versions, monostable
Contact arrangement 2 form C (CO) Coil Rated Operate Limiting Release Coil Rated coil
Max. switching voltage 220VDC, 250VAC code voltage voltage voltage voltage resistance power
Rated current 2A VDC VDC VDC VDC ??10% mW
Limiting continuous current 2A Standard version, monostable, 1 coil
Switching power 60W, 62.5VA 06 3 2.10 6.30 0.30 64 140
Contact material PdRu, Au covered 07 4 2.80 8.40 0.40 114 140
Contact style bifurcated contacts 04 4.5 3.15 9.40 0.45 145 140
Min. recommended contact load 100?V/1?A 09 5 3.50 10.50 0.50 178 140
Initial contact resistance <70m? 05 6 4.20 12.60 0.60 257 140
Thermoelectric potential <10?V 10 9 6.30 18.90 0.90 574 140
Operate time typ. 3ms, max. 4ms 02 12 8.40 25.20 1.20 1028 140
Release time 12 24 16.80 42.20 2.40 2880 200
without diode in parallel typ. 1ms, max. 3ms 13 48 33.60 68.90 4.80 7680 300
with diode in parallel typ. 3ms, max. 4ms High sensitive version, monostable, 1 coil
Set/reset time min. 20ms 21 3 2.10 8.30 0.30 113 80
Bounce time max. typ. 1ms, max. 5ms 22 4.5 3.15 11.10 0.45 253 80
Electrical endurance 23 5 3.50 12.50 0.50 313 80
at contact application 0 24 6 4.20 13.90 0.60 450 80
AXICOM
6
(= 30mV / = 10mA) min. 2.5x10 operations 25 9 6.30 16.70 0.90 1013 80
6 Telecom-, Signal and RF Relays 108-98003 Rev. G
cable load open end min. 2.0x10 operations 26 12 8.40 33.40 1.20 1800 80
5
resistive, 24V / 1.25A - 30W min. 5x10 operations 27 24 16.80 50.40 2.40 4114 140
5
FX2 Relay
resistive, 30VDC / 2A - 60W min. 5x10 operations 28 48 36.00 70.00 4.80 8882 260
5
resistive, 125VDC / 0.24A - 30W min. 5x10 operations High dielectric version, monostable, 1 coil
UL contact rating 30VDC, 2A, 60W 91 3 2.25 6.3 0.30 45 200
125VDC, 0.5A, 62,5W 92 4.5 3.15 9.45 0.45 101 200
Coil Operating Range
120VDC, 1.25A, 150W 96 12 8.40 25.2 1.20 720 200
6
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Mechanical endurance 100x10 operations
Unom = Nominal coil voltage
Max. DC load breaking capacity 80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
the coil voltage (limiting voltage)
3.2
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Ambient Temperature [?C]
DC current [A]
1
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
260 mW
a TE Connectivity Ltd. company http://relays.te.com/definitions
300 mW
2.6
2.4
Umax. at 0 A
2.2
Umax. at 2 x 1 A
2.0
Umax. at 2 x 2 A
1.8
1.6
1.4
1.2
1.0
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4
Urel. min.
0.2
0.0
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
Ambient Temperature [?C]
4.4
100 mW Latching
4.2
4
3.8
3.6
3.4
3.2
3
2.8
2.6
2.4
2.2
2 Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
DC voltage [VDC]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom]AXICOM
Telecom-, Signal and RF Relays 108-98003 Rev. G
FX2 Relay
Coil Operating Range
Unom = Nominal coil voltage
80 mW
140 mW
Umax. = Upper limit of the operative range of
3.4
200 mW
3.2 the coil voltage (limiting voltage)
AXICOM
Umax. at 0 A
3
Uop. min. = Lower limit of the operative range of the
Telecom-, Signal and RF Relays 108-98003 Rev. G
Umax. at 2 x 1 A
2.8
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
For latching relays Uset min. resp. Ureset min.
2.4
FX2 Relay
2.2
Urel. min. = Lower limit of the operative range of
2
the coil voltage (reliable release voltage)
1.8
1.6
Coil Operating Range
1.4
1.2
1
Unom. nominal coil voltage
Signal Relays
AXICOM
0.8
Unom = Nominal coil voltage
0.6 80 mW
Uop. min.
140 mW
0.4 Umax. = Upper limit of the operative range of
3.4 Urel. min. 200 mW
0.2
the coil voltage (limiting voltage)
3.2
FX2 Relay (Continued)
0
Umax. at 0 A
3
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
Uop. min. = Lower limit of the operative range of the
Umax. at 2 x 1 A
2.8
Ambient Temperature [?C]
coil voltage (reliable operate voltage)
Umax. at 2 x 2 A
2.6
2.4 For latching relays Uset min. resp. Ureset min.
2.2
Coil Data (continued) Urel. min. = InsulationLower limit of the operative range of standar d* high dielectric*
2
Initial dielectric strength
the coil voltage (reliable release voltage)
1.8
260 mW
between open contacts 1800V 2100V
1.6 rms rms
2.6 300 mW
1.4 between contact and coil 1800V 4000V
rms rms
2.4
1.2
between adjacent contacts 1800V 2100V
rms rms
Umax. at 0 A
2.12
Unom. nominal coil voltage
Umax. at 2 x 1 A Initial surge withstand voltage
0.8
2.0
Umax. at 2 x 2 A
between open contacts 2500V 2900V
0.6
Uop. min.
1.8
0.4
between contact and coil 3500V 6000V
Urel. min.
0.2
1.6
between adjacent contacts 2500V 2900V
0
1.4
Initial insulation resistance
-60 -50 -40-30 -20 -100 10 20 30 40 50 60 70 80 90 100 110 120
9 9
1.2
Ambient Temperature [?C] between insulated elements >10? >10 ?
1.0
Capacitance
Unom. nominal coil voltage
0.8
between open contacts max. 4pF
0.6 between contact and coil max. 2pF
Uop. min.
0.4 between adjacent contacts max. 2pF
260 mW
Urel. min.
2.6 300 mW
Cross talk at 100MHz/900MHz -34.0dB/-15.1dB
0.2
2.4
Insertion loss at 100MHz/900MHz 0.03dB/0.60dB
0.0
Umax. at 0 A
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
2.2 Voltage standing wave ratio (VSWR)
Umax. at 2 x 1 A
Ambient Temperature [?C]
2.0 at 100MHz/900MHz 1.07/1.45
Umax. at 2 x 2 A
Coil versions, bistable 1 coil
1.8
*this relay contains SF6 (Sulfur hexafluoride, CAS number: 2551-62-4) for dielectric strength
Coil Rated Set Limiting Reset Coil Rated coil
1.6
enhancement, SF6 is hermetically sealed in relay without leaks to air during normal applica-
code voltage voltage voltage voltage resistance power
1.4 tion as recommended per the applicable product specification. It is clarified that the usage
4.4
VDC VDC VDC VDC100 mW Latching ??10% mW
of SF6 in mini signal relay is not prohibited by related regulations. Please contact TE local
1.2
4.2
sales or field engineer for further information and detailed material declaration.
Standard, bistable 1 coil
4
1.0
3.8
41 U3nom . nominal coil voltage2.25 7.50 -2.25 90 100
0.8
3.6
42 4.5 3.38 11.20 -3.38 203 100
3.4
0.6
3.2
43 5 3.75 12.40 -3.75U op. min. 250 100 Other Data
0.4
3
Urel. min.
44 6 4.50 14.90 -4.50 360 100 Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
2.8
0.2
2.6
45 9 6.75 22.40 -6.75 810 100 refer to the Product Compliance Support Center at
0.0
2.4
-60-50 -40-30 -20-10 0102030405060708090 100 110 120
46 12 9.00 29.80 -9.00 1440 100 www.te.com/customersupport/rohssupportcenter
2.2
2
47 U24max. - 100 % coil duty at 0 18.00Ambient Temperature [?C] 48.70A -18.00 3840 150 Ambient temperature -40?C to +85?C
1.8
Umax. - 5 % coil duty at 2 x 2 A
High dielectric version, bistable 1 coil Category of environmental protection
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
62 4.5 3.15 11.20 -3.15 203 100 IEC 61810 RT V - immersion cleanable
1.2 Umax. - 5 % coil duty at 0 A
All figures are given for coil without pre-energization, at ambient temperature +23?C.
Degree of protection, IEC 60529 IP 67, immersion cleanable
1
Unom. nominal coil voltage
4.0.48 Vibration resistance (functional) 20g, 10 to 500Hz
100 mW Latching
4.0.62
Shock resistance (functional), half sinus 11ms 50g
0.44
Uset min.
0.2 Shock resistance (destructive), half sinus 0.5ms 1500g
3.8
0
3.6
Weight max. 2.5g
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
3.4
Ambient Temperature [?C] Resistance to soldering heat THT Peek value
3.2
3
IEC 60068-2-20 265?C/10s
2.8
Ultrasonic cleaning not recommended
2.6
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
2.4
Packaging/unit tube/50 pcs., box/1000 pcs.
2.2
2
Umax. - 100 % coil duty at 0 A
1.8
Umax. - 5 % coil duty at 2 x 2 A
1.6
Umax. - 5 % coil duty at 2 x 1 A
1.4
Umax. - 5 % coil duty at 0 A
1.2
1
Unom. nominal coil voltage
0.8
0.6
0.4
Uset min.
0.2
0
-60-50 -40-30 -20-10 0102030405060708090100 110120 130140
Ambient Temperature [?C]
Other coil voltages on request.
U upper limit of the operative range of the coil voltage (limiting voltage) when coils are
max
All speci?cations subject to change. Consult Tyco Electronics for latest speci?cations. 5 of 11
continuously energized
U lower limit of the operative range of the coil voltage (reliable operate voltage)
op min
U lower limit of the operative range of the coil voltage (reliable release voltage)
rel min
Terminal assignment
TOP view on component side of PCB PCB layout
TOP view on component side of PCB
Monostable Bistable, 1 coil
Contacts are shown in reset
condition.
Both coils can be used as
either set or reset coils.
Contact position might
change during transportation
and must be reset before
use.
2
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom] Coil Voltage [U/Unom]
Coil Voltage [U/Unom] Coil Voltage [U/Unom]Signal Relays
AXICOM
FX2 Relay (Continued)
Dimensions Packing
14.95?0.05 7.3?0.05
0.5
5.08?0.15
Product code structure Typical product code D32 04
Type
D32 Signal Relays FX2
2 form C, 2 CO
Coil
Coil code: please refer to coil versions table
Performance and coil type
0x,1x Standard version, monostable
2x High sensitive version, monostable
4x Standard version bistable
9x High dielectric version, monostable
6x High dielectric version, bistable
Product code Arrangement Perf. type Coil type Coil Part number
D3206 2 form C (2 CO) Standard Monostable 3VDC 1462034-6
D3207 4VDC 1462034-8
D3204 4.5VDC 1462034-2
D3209 5VDC 1462034-9
D3205 6VDC 1462034-5
D3210 9VDC 1-1462034-3
D3202 12VDC 1462034-1
D3212 24VDC 1-1462034-4
D3213 48VDC 1-1462034-5
D3221 2 form C (2 CO) High sensitive Monostable 3VDC 1-1462034-9
D3222 4.5VDC 2-1462034-0
D3223 5VDC 2-1462034-1
D3225 9VDC 2-1462034-3
D3226 12VDC 2-1462034-4
D3227 24VDC 2-1462034-5
D3228 48VDC 2-1462034-6
D3241 2 form C (2 CO) Standard Bistable 3VDC 2-1462034-8
D3242 4.5VDC 2-1462034-9
D3243 5VDC 3-1462034-0
D3246 12VDC 3-1462034-3
D3247 24VDC 3-1462034-4
D3291 2 form C (2 CO) High dielectric Monostable 3VDC 6-1462034-6
D3292 4.5VDC 6-1462034-8
D3296 12VDC 6-1462034-7
D3262 2 form C (2 CO) High dielectric Bistable 4.5VDC 6-1462034-3
This list represents the most common types and does not show all variants covered by this data sheet.
Other types on request
3
01-2016, Rev. 0116 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, ?Definitions? sec -
www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications
? 2015 Tyco Electronics Corporation, only together with the ?Definitions? section. the ?Definitions? section, available at are subject to change.
a TE Connectivity Ltd. company http://relays.te.com/definitions
0.3?0.05
3.3?0.3 10.7?0.05