Product Information

LY2ZN-D2 DC100/110

LY2ZN-D2 DC100/110 electronic component of Omron

Datasheet
General Purpose Relays General Purpose Relay

Manufacturer: Omron
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 42.5124 ea
Line Total: USD 42.5124

7 - Global Stock
Ships to you between
Thu. 11 Apr to Mon. 15 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
7 - Global Stock


Ships to you between Thu. 11 Apr to Mon. 15 Apr

MOQ : 1
Multiples : 1
1 : USD 26.9445
10 : USD 25.5875
100 : USD 23.2875

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Coil Voltage
Contact Form
Contact Current Rating
Mounting Style
Switching Voltage
Coil Type
Coil Resistance
Coil Current
Contact Material
Series
Power Consumption
Brand
Product Type
Relay Contact Form
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
LY3-0-AC120 electronic component of Omron LY3-0-AC120

General Purpose Relays PCB 3PDT 120VAC
Stock : 0

LY2ZNDC12 electronic component of Omron LY2ZNDC12

Power Relay 12VDC 7A DPDT(28x21.5x42.4)mm Socket
Stock : 16

LY3-0-AC240 electronic component of Omron LY3-0-AC240

General Purpose Relays GP RELAY
Stock : 115

LY2ZN-D2 DC24 electronic component of Omron LY2ZN-D2 DC24

General Purpose Relays GP RELAY
Stock : 2

LY2ZN-DC24 electronic component of Omron LY2ZN-DC24

General Purpose Relays GP RELAY
Stock : 8

LY3-0-AC200/220 electronic component of Omron LY3-0-AC200/220

Electromechanical Relay 200/220VAC 8.65KOhm 10A 3PDT (28x21.5x36)mm THT General Purpose Relay
Stock : 16

LY3-0-AC24 electronic component of Omron LY3-0-AC24

General Purpose Relays GP RELAY
Stock : 1

LY2ZND2DC100110 electronic component of Omron LY2ZND2DC100110

General Purpose Relay
Stock : 0

LY3-0-DC12 electronic component of Omron LY3-0-DC12

General Purpose Relays GP RELAY
Stock : 50

Image Description
LY2ZF AC200/220 electronic component of Omron LY2ZF AC200/220

General Purpose Relays GP RELAY
Stock : 0

LY2Z AC220/240 electronic component of Omron LY2Z AC220/240

General Purpose Relays General Purpose Relay
Stock : 2

LY2I4N AC100/110 electronic component of Omron LY2I4N AC100/110

General Purpose Relays GP RELAY
Stock : 2

J7TKN-C-42 electronic component of Omron J7TKN-C-42

Contactors - Electromechanical Contactor
Stock : 2

G9EA-1-CA DC48 electronic component of Omron G9EA-1-CA DC48

General Purpose Relays High Current Leads SPST-NO 48V 30A
Stock : 0

G7L-2A-TUB-CB-IN AC24 electronic component of Omron G7L-2A-TUB-CB-IN AC24

General Purpose Relays 25A GP RY 2A QC PNL VDE HP
Stock : 0

G7L-2A-TUB-80-CB AC100/120 electronic component of Omron G7L-2A-TUB-80-CB AC100/120

General Purpose Relays RELAY
Stock : 0

G7J-3A1B-B AC100/120 electronic component of Omron G7J-3A1B-B AC100/120

General Purpose Relays RELAY
Stock : 3

G6QE-1A DC5 electronic component of Omron G6QE-1A DC5

General Purpose Relays Mini PCB Power Relay Single Pole 32A, 5V
Stock : 8

G6B-2214P-1-US DC12 electronic component of Omron G6B-2214P-1-US DC12

General Purpose Relays Power PCB Relay
Stock : 1

Bi-power Relays LY E Power-switching Compact General-purpose Relays * Wiring work can be shortened by as much as 60% compared to conventional screw terminal sockets by combining with push-in plus terminal sockets (PYF- -PU) that feature light insertion force and strong pull-out strength to achieve less wiring work. The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and Material Safety Act. Equipped with an arc barrier for arc interruption. Withstand voltages up to 2,000 V. New built-in diode and built-in CR circuit models have Refer to the standards certifications and compliance section of your joined the series. OMRON website for the latest information on certified models. The lineup also includes models that are compliant with the LR and VDE safety standards. * When both push-in plus terminals and screw terminal sockets are combined with plug-in terminal types (according to actual OMRON measurements as of November 2015) Refer to the Common Relay Precautions. Model Number Structure Relays with Plug-in Terminals Relays with PCB Terminals Case-surface mounting Structure Number Classification With operation indicators of poles 1 *LY1 **LY1N *LY1-0 *LY1F Standard models *LY2 **LY2N *LY2-0 *LY2F 2 Bifur- Compliance with **LY2Z **LY2ZN **LY2Z-0 **LY2ZF cated Electrical Appliances and Material Safety Act 3 *LY3 **LY3N *LY3-0 *LY3F 4 *LY4 **LY4N *LY4-0 *LY4F 1 **LY1-D **LY1N-D2 --- --- Models with diode for --- --- **LY2-D **LY2N-D2 coil surge absorption (DC coil specification 2 Bifur- --- --- **LY2Z-D **LY2ZN-D2 only) cated 3 --- --- **LY3-D **LY3N-D2 4 **LY4-D **LY4N-D2 --- --- Models with CR circuits 1 --- --- for coil surge **LY2-CR **LY2N-CR absorption 2 Bifur- (AC coil specification **LY2Z-CR **LY2ZN-CR cated only) Note: 1. Cells with a diagonal line cannot be manufactured. Ask your OMRON representative for details on manufacturing products for cells containing --- in the above table. 2. If 187 tab terminals are required, use the LY1F-T2 or LY2F-T2 (single-pole or double-pole models only). 3. Refer to page 21 for information on plug-in terminal and socket combinations. 4. Items with an asterisk (*) in the table are certified for UL, CSA, and SEV. This is indicated with a certification mark on the products. 5. Items with two asterisks (**) in the table are certified for UL and CSA. This is indicated with a certification mark on the products. 6. All models in the table are certified for IEC (TV). 7. The models with plug-in terminals (single-pole, double-pole, and 4-pole) were combined with the PTF-E for the EC Declaration of Conformity. These products display the CE Marking. 1 LY Ordering Information Relays Models with Plug-in Terminals Number of poles 1 pole 2 poles 3 poles 4 poles Classification Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) 12, 24, 100/110, 12, 24, 100/110,110/ 12, 24, 100/110, or 12, 24, 100/110, or 110/120, 120, 200/220, 200/220 VAC 200/220 VAC or 200/220 VAC or220/240 VAC Standard models LY1 LY2 LY3 LY4 12, 24, 48, 12, 24, 48, 12, 24, 48, 12, 24, 48, or 100/110 VDC or 100/110 VDC or 100/110 VDC or 100/110 VDC 12, 24, 100/110, 12, 24, 100/110,110/ 12, 24, 100/110, or 12, 24, 100/110, or 110/120, 120, 200/220, 200/220 VAC 200/220 VAC Models with built-in or 200/220 VAC or 220/240 VAC LY1N LY2N LY3N LY4N operation indicators 12, 24, 12, 24, 48, 12, 24, 48, 12, 24, 48, Models with or 100/110 VDC or 100/110 VDC or 100/110 VDC or 100/110 VDC single Models with built-in 12, 24, 48, 12, 24, 48, 12, 24, 48, 12, 24, 48, LY1-D LY2-D LY3-D LY4-D contacts diodes or 100/110 VDC or 100/110 VDC or 100/110 VDC or 100/110 VDC Models with built-in LY1N- 12, 24, 48, LY3N- 12, 24, LY4N- 12, 24, 48, diodes and 12, 24, or 48 VDC LY2N-D2 D2 or 100/110 VDC D2 or 100/110 VDC D2 or 100/110 VDC operation indicators 100/110, 110/120, Models with built-in --- --- LY2-CR 200/220, or 220/240 --- --- --- --- CR circuits VAC Models with built-in 100/110, 110/120, CR circuits and --- --- LY2N-CR 200/220, or 220/240 --- --- --- --- operation indicators VAC 100/110 or200/220 --- --- --- --- --- --- VAC Standard models LY2Z 12, 24, 48, or 100/ --- --- --- --- --- --- 110 VDC 100/110, 110/120, --- --- 200/220, --- --- --- --- Models with built-in LY2ZN or 220/240 VAC operation indicators --- --- 12 or 24 VDC --- --- --- --- Bifurcated Models with built-in --- --- LY2Z-D 12, 24, or 48 VDC --- --- --- --- contacts diodes Models with built-in LY2ZN- 12, 24, or 100/110 diodes and --- --- --- --- --- --- D2 VDC operation indicators Models with built-in --- --- LY2Z-CR 100/110 VAC --- --- --- --- CR circuits Models with built-in LY2ZN- 100, 110, 110/1 20, CR circuits and --- --- --- --- --- --- CR or 200/220 VAC operation indicators Relays with PCB Terminals Number of poles 1 pole 2 poles 3 poles 4 poles Classification Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) 24,100/110, 12, 24, 24, 100/110, 24, 100/110, or 200/ 110/120, or 200/220 100/110, 110/120, 200/ or 200/220 VAC 220 VAC Models with single VAC 220, or 220/240 VAC LY1-0 LY2-0 LY3-0 LY4-0 contacts 12, 24, 48 12, 24, 48, or 12, 24, 48, or 12 or 24 VDC or 100/110 VDC 100/110 VDC 100/110 VDC 100/110 VAC --- Bifurcated contacts --- --- LY2Z-0 --- --- --- 24, 48, or --- 100/110 VDC Case-surface Mounting Number of poles 1 pole 2 poles 3 poles 4 poles Classification Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) Model Rated voltage (V) 24, 100/110, 12, 24, 100/110, 110/ 12, 24, 100/110, 12, 24, 100/110, 110/120, 200/220, 120, 200/220, or 200/220 VAC or 200/220 VAC Models with single or 220/240 VAC or 220/240 VAC LY1F LY2F LY3F LY4F contacts 6, 12, 24, or 100/110 12, 24, 48, or 100/110 12, 24, or 100/110 12, 24, or 100/110 VDC VDC VDC VDC 24, 100/110, or 200/220 VAC Bifurcated contacts --- --- LY2ZF --- --- --- --- 12 or 24 VDC 2

Tariff Desc

8536.49.00 TC 17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC 8909066 having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 low profile, OTHER THAN reed relays, being EITHER of the following
a) height NOT exceeding 21.24mm
b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following
a) one, two or three contacts
b) maximum continuous contact current rating of NOT less than 15A
c) maximum contact voltage rating of NOT less than 380V
d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts having ANY of the following:
a) spring loaded terminals
b) plug-in screw terminals
c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following
a) maximum switching current NOT exceeding 5A AC or DC
b) switching voltage NOT exceeding 250V AC or DC
c) body dimensions NOT exceeding 31mm x 36mm x 19mm

8536.49 TC 8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics
a) trip time NOT exceeding 5 s at 6 times full load current
b) manual reset
c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following
a) normally closed main poles
b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8536.49.00 solid state having an operating voltage NOT exceeding 600VAC or 300VDC but NOT including protective monitoring TC 9320885
OM4
OMRON
Omron Automation
Omron Automation & Safety
Omron Automation and Safety
OMRON AUTOMATION CANADA
OMRON ELECTRONIC COM
OMRON ELECTRONIC COMPONENTS
OMRON ELECTRONICS
Omron Electronics In
Omron Electronics Inc-EMC Div
Omron Electronics Inc-IA Div
OMRON INDUSTRIAL
OMRON INDUSTRIAL AUTOMATION
Omron Industrial Products
OMRON OCB
OMRON SAFETY
OMRON STI

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted