Small Sealed Switch D4E- N CSM D4E- N DS E 4 1 Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action and long life expectancy. Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time. One touch connector eliminates need for tedious wiring operations and reduces downtime for wiring and maintenance (models with standard, easy-to-use screw terminals are also available). Minute load model with gold cladding is optimal for electronic control. Molded terminal types as well as molded terminal types with operating indicator lamps are available for screw terminal systems. Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.) No difference in mounting pitch and characteristics between D4E- N and D4E models. Be sure to read Safety Precautions on page 9 to 10 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) D4E- N (1)(2) (3) (4) (1) Rated Current (3) Terminals (4) Operation Indicator 1: 5 A at 125 VAC 00: AC connector None: Without operation indicator (1 A at 125 VAC/30 VDC for model with a 10: DC connector L: Neon lamp (250 VAC) connector) 20: Screw terminals without a cable L2: LED (24 VDC) 2: 0.1 A at 125 VAC 21: Screw terminals with a cable (right-hand) Note: Only the molded terminal models can be (0.1 A at 125 VAC/30 VDC for model with a 22: Screw terminals with a cable (left-hand) equipped with an operation indicators. connector) 23: Molded terminals with a cable (right-hand) 24: Molded terminals with a cable (left-hand) (Cable is S-FLEX VCTF 3 m) (2) Actuator Note: The terminal specifications in model numbers are A: Roller plunger not the same for D4E-N and D4E Switches. B: Crossroller plunger Comparison of New and Old Molded C: Plunger Terminal Models D: Sealed roller plunger E: Sealed crossroller plunger Model F: Sealed plunger Location of D4E-N D4E G: Roller lever lead outlet H: One-way action roller lever Right-hand D4E- 23N D4E- 21 Left-hand D4E- 24N D4E- 23 1D4E- N Ordering Information Type One-touch connector type Screw terminal type General-purpose Micro load General-purpose Micro load with General-purpose Micro load without cable without cable with cable cable Actuator Model Model Model Model Model Model Roller plunger D4E-1A 0N D4E-2A10N D4E-1A20N D4E-2A20N D4E-1A21N D4E-2A21N Crossroller D4E-1B 0N D4E-2B10N D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N plunger D4E-1C 0N D4E-2C 0N D4E-1C20N D4E-2C20N D4E-1C21N D4E-2C21N Plunger Sealed roller D4E-1D 0N D4E-2D10N D4E-1D20N D4E-2D20N D4E-1D21N D4E-2D21N plunger Sealed crossroller D4E-1E 0N --- D4E-1E20N D4E-2E20N D4E-1E21N D4E-2E21N plunger D4E-1F 0N D4E-2F10N D4E-1F20N D4E-2F20N D4E-1F21N D4E-2F21N Sealed plunger D4E-1G 0N D4E-2G10N D4E-1G20N D4E-2G20N D4E-1G21N D4E-2G21N Roller lever One-way action D4E-1H00N --- D4E-1H20N D4E-2H20N D4E-1H21N --- roller lever Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector or 1 for DC connector. 2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed. 3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to page 8. Plug Select one of the specified Connector Plugs from the following table. Applicable limit Current No. of Type Cable length Plug switches Type conductors 2 m XS2F-A421-D90-A Straight D4E- 00N AC 5 m XS2F-A421-G90-A 4 2 m XS2F-D421-D80-A D4E- 10N DC 5 m XS2F-D421-G80-A Specifications Approved Standards Agency Standard File No. Approved models UL UL508 E76675 D4E- 20N Switches only except for Indicator-equipped Switches CSA CSA C22.2 No. 14 LR45746 D4E- 20N Switches only except for Indicator-equipped Switches TV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on approved models. CCC (CQC) GB14048.5 2003010305086795 Ask your OMRON representative for information on approved models. Ratings Standard load Micro load NC 10 A max. Inrush current Non-inductive load (A) Inductive load (A) Non-inductive load (A) NO 10 A max. Rated voltage Resistive load Lamp load Inductive load Motor load Resistive load Note: 1. The above current ratings are for a standard current and the values in NC NO NC NO NC NO NC NO NC NO parentheses are for models with a 125 VAC 5 (1) 1.5 (1) 3 (1) 2 (1) 1 (1) 0.1 connector. 5 (1) 1.5 (1) 3 (1) 1 0.5 --- 250 VAC 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms 8 VDC 5 (1) 1.5 (1) 0.1 --- --- max. (DC). 14 VDC 5 (1) 1.5 (1) 0.1 --- --- 3. Lamp load has an inrush current of 10 30 VDC 5 (1) 1.5 (1) 0.1 --- --- times the steady-state current. 0.5 0.05 --- 125 VDC --- --- 4. Motor load has an inrush current of 6 --- --- 0.25 0.03 --- 250 VDC times the steady-state current. Standard load Micro load Minimum applicable 160 mA at 5 1 mA at 5 VDC load VDC 2