Product Information

U-CYCLONE

Product Image X-ON

Programmers - Processor Based U-CYCLONE
Manufacturer: NXP


Price (Ex GST)

From 1467.0179

79 - Global Stock
Ships to you between
Thu. 03 Dec to Mon. 07 Dec
MOQ: 1 Multiples:
Pack Size :   1
Availability Price Quantity
78 - Global Stock


Ships to you between Thu. 03 Dec to Mon. 07 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 1467.0179

Buy
4 - Global Stock


Ships to you between Fri. 04 Dec to Thu. 10 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 2366.2405

Buy
         
Manufacturer
NXP
Product Category
Programmers - Processor Based
RoHS - XON
Y Icon ROHS
Product
In-Circuit Programmersÿÿ
Tool Is For Evaluation Of
Nxp 8 Bit, 16 Bit, 32 Bit, Arm
Core
Arm, Coldfire, Hc08, Hc12, Hcs08, Hcs12, Mpc5xx/8Xx, Rs08, S12
Operating Supply Voltage
1.6 v to 5.2 V
Brand
NXP
Factory Pack Quantity :
1
Cnhts
8543909000
Hts Code
8471500150
Mxhts
84715001
Product Type
Programmers - Processor Based
Qualification
Aec-Q100
Subcategory
Embedded Solutions
Taric
8471500000
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image UDA1334ATS/N2,118
Digital to Analog Converters - DAC ULTRA LOW COST DAC
Stock : 1790
Image Description
Stock Image U-MULTILINK-FX
Programmers - Processor Based Univ MultilinkFX
Stock : 127
Stock Image JTAG HS2 PROGRAMMING CABLE
Programmer: Xilinx FPGA; USB; 30Mbps
Stock : 8
Stock Image JTAG-SMT2-NC SM PROGRAMMING MODULE
Programmer: Xilinx FPGA; USB; 30Mbps; Mounting: SMD; 3.3VDC
Stock : 50
Stock Image USB-DONGLE
Programmers - Processor Based USB Dongle Rev 3
Stock : 193
Stock Image USB-FPA-MSP430-CC
Programmers - Processor Based FlashPro430/ FlashPro-CC STD VER.
Stock : 2
Stock Image USB-MSP430-FPA-GANG-J
Programmers - Processor Based GangPro430 JTAG/SBW
Stock : 7
Stock Image USB-MSP430-FPA-LB
Programmers - Processor Based FlashPro430 LITE BSL ONLY
Stock : 1
Stock Image USB-MSP430-FPA-LJ
Programmers - Processor Based FlashPro430 LITE JTAG/SBW
Stock : 3
Stock Image USB-MSP430-FPA-LJB
Programmers - Processor Based FlashPro430 LITE FOR TI MSP430 MCU
Stock : 10
Stock Image 410-242
Programmers - Processor Based chipKIT PGM Programmer/Debugger
Stock : 3

CYCLONE Programmers User ManualCYCLONE Programmers User ManualPurchase Agreement P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein. This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this software in violation of copyright law or the terms of this agreement will be prosecuted. All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software. P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no conditions may you remove the copyright notices from this software or documentation. This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each user in the group. Contact P&E for volume discounts and site licensing agreements. P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage. By using this software, you accept the terms of this agreement. ?2015-2016 P&E Microcomputer Systems, Inc. ARM and Cortex are registered trademarksof ARM Ltd. or its subsidiaries. NXP, ColdFire, and Kinetis are registered trademarks of NXP Semiconductors. Texas Instruments and TI are registered trademarks of Texas Instruments Incorporated. STMicroelectronics is a registered trademark of STMicroelectronics, Inc. All other product or service names are the property of their respective owners. P&E Microcomputer Systems, Inc. 98 Galen St. Watertown, MA 02472 617-923-0053 http://www.pemicro.com Manual version: 1.01 April 2017CYCLONE Programmers User ManualCYCLONE Programmers User ManualPurchase Agreement P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein. This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this software in violation of copyright law or the terms of this agreement will be prosecuted. All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software. P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no conditions may you remove the copyright notices from this software or documentation. This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each user in the group. Contact P&E for volume discounts and site licensing agreements. P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage. By using this software, you accept the terms of this agreement. ?2015-2016 P&E Microcomputer Systems, Inc. ARM and Cortex are registered trademarksof ARM Ltd. or its subsidiaries. NXP, ColdFire, and Kinetis are registered trademarks of NXP Semiconductors. Texas Instruments and TI are registered trademarks of Texas Instruments Incorporated. STMicroelectronics is a registered trademark of STMicroelectronics, Inc. All other product or service names are the property of their respective owners. P&E Microcomputer Systems, Inc. 98 Galen St. Watertown, MA 02472 617-923-0053 http://www.pemicro.com Manual version: 1.01 April 20171 INTRODUCTION.............................................................................................1 1.1 Feature Overview/Comparison....................................................................... 1 2 QUICK START GUIDE FOR SAP OPERATION.............................................2 3 CYCLONE HARDWARE.................................................................................5 3.1 Touchscreen LCD .......................................................................................... 5 3.2 LED Indicators................................................................................................ 5 3.3 Start Button .................................................................................................... 5 3.4 Access Panel.................................................................................................. 5 3.5 Cyclone System Power .................................................................................. 6 3.6 RS232 Communication (Serial Port) .............................................................. 6 3.7 Ethernet Communication................................................................................ 6 3.8 USB Communications .................................................................................... 6 3.9 Electromechanical Relays.............................................................................. 6 3.10 Power Connectors.......................................................................................... 7 3.11 Reset Button................................................................................................... 7 3.12 Optional Oscillator (MON08 Only).................................................................. 7 3.13 Cyclone Time / Real Time Clock.................................................................... 7 3.14 Power Jumper Settings .................................................................................. 8 3.15 Debug Connectors ......................................................................................... 8 3.16 Target Headers For Part# CYCLONE_ACP................................................... 9 3.17 Target Headers For Part# CYCLONE_UNIVERSAL.................................... 12 3.18 Ribbon Cable................................................................................................ 18 4 TARGET POWER MANAGEMENT ..............................................................19 4.1 Cyclone Configuration.................................................................................. 19 4.2 Cyclone Setup.............................................................................................. 21 4.3 Setup Reminders.......................................................................................... 23 5 TOUCHSCREEN LCD MENU.......................................................................24 5.1 Home Screen ............................................................................................... 24 5.2 Main Menu.................................................................................................... 25 6 STAND-ALONE PROGRAMMER CONFIGURATION ..................................31 6.1 Create A Stand-Alone Programming (SAP) Image ...................................... 31 6.2 Manage Multiple SAP Images...................................................................... 38 7 STAND-ALONE PROGRAMMER MANUAL CONTROL...............................41 7.1 Operation Via Start Button ........................................................................... 41 7.2 Operation Via LCD Touchscreen Menu ....................................................... 41 7.3 Home Screen ............................................................................................... 42 7.4 Status Window ............................................................................................. 42 8 STAND-ALONE PROGRAMMER AUTOMATED CONTROL .......................45 8.1 Cyclone Automated Control Package - Overview ........................................ 45CYCLONE Programmers User ManualCYCLONE Programmers User ManualPurchase Agreement P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein. This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this software in violation of copyright law or the terms of this agreement will be prosecuted. All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software. P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no conditions may you remove the copyright notices from this software or documentation. This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each user in the group. Contact P&E for volume discounts and site licensing agreements. P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage. By using this software, you accept the terms of this agreement. ?2015-2016 P&E Microcomputer Systems, Inc. ARM and Cortex are registered trademarksof ARM Ltd. or its subsidiaries. NXP, ColdFire, and Kinetis are registered trademarks of NXP Semiconductors. Texas Instruments and TI are registered trademarks of Texas Instruments Incorporated. STMicroelectronics is a registered trademark of STMicroelectronics, Inc. All other product or service names are the property of their respective owners. P&E Microcomputer Systems, Inc. 98 Galen St. Watertown, MA 02472 617-923-0053 http://www.pemicro.com Manual version: 1.01 April 2017CYCLONE Programmers User ManualCYCLONE Programmers User ManualPurchase Agreement P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein. This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this software in violation of copyright law or the terms of this agreement will be prosecuted. All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software. P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no conditions may you remove the copyright notices from this software or documentation. This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each user in the group. Contact P&E for volume discounts and site licensing agreements. P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage. By using this software, you accept the terms of this agreement. ?2015-2016 P&E Microcomputer Systems, Inc. ARM and Cortex are registered trademarksof ARM Ltd. or its subsidiaries. NXP, ColdFire, and Kinetis are registered trademarks of NXP Semiconductors. Texas Instruments and TI are registered trademarks of Texas Instruments Incorporated. STMicroelectronics is a registered trademark of STMicroelectronics, Inc. All other product or service names are the property of their respective owners. P&E Microcomputer Systems, Inc. 98 Galen St. Watertown, MA 02472 617-923-0053 http://www.pemicro.com Manual version: 1.01 April 20171 INTRODUCTION.............................................................................................1 1.1 Feature Overview/Comparison....................................................................... 1 2 QUICK START GUIDE FOR SAP OPERATION.............................................2 3 CYCLONE HARDWARE.................................................................................5 3.1 Touchscreen LCD .......................................................................................... 5 3.2 LED Indicators................................................................................................ 5 3.3 Start Button .................................................................................................... 5 3.4 Access Panel.................................................................................................. 5 3.5 Cyclone System Power .................................................................................. 6 3.6 RS232 Communication (Serial Port) .............................................................. 6 3.7 Ethernet Communication................................................................................ 6 3.8 USB Communications .................................................................................... 6 3.9 Electromechanical Relays.............................................................................. 6 3.10 Power Connectors.......................................................................................... 7 3.11 Reset Button................................................................................................... 7 3.12 Optional Oscillator (MON08 Only).................................................................. 7 3.13 Cyclone Time / Real Time Clock.................................................................... 7 3.14 Power Jumper Settings .................................................................................. 8 3.15 Debug Connectors ......................................................................................... 8 3.16 Target Headers For Part# CYCLONE_ACP................................................... 9 3.17 Target Headers For Part# CYCLONE_UNIVERSAL.................................... 12 3.18 Ribbon Cable................................................................................................ 18 4 TARGET POWER MANAGEMENT ..............................................................19 4.1 Cyclone Configuration.................................................................................. 19 4.2 Cyclone Setup.............................................................................................. 21 4.3 Setup Reminders.......................................................................................... 23 5 TOUCHSCREEN LCD MENU.......................................................................24 5.1 Home Screen ............................................................................................... 24 5.2 Main Menu.................................................................................................... 25 6 STAND-ALONE PROGRAMMER CONFIGURATION ..................................31 6.1 Create A Stand-Alone Programming (SAP) Image ...................................... 31 6.2 Manage Multiple SAP Images...................................................................... 38 7 STAND-ALONE PROGRAMMER MANUAL CONTROL...............................41 7.1 Operation Via Start Button ........................................................................... 41 7.2 Operation Via LCD Touchscreen Menu ....................................................... 41 7.3 Home Screen ............................................................................................... 42 7.4 Status Window ............................................................................................. 42 8 STAND-ALONE PROGRAMMER AUTOMATED CONTROL .......................45 8.1 Cyclone Automated Control Package - Overview ........................................ 45

Customer Comments  

Log in or register to post comments.

Customer Reviews