Product Information

CRL2S1205SC

CRL2S1205SC electronic component of Murata

Datasheet
Isolated DC/DC Converters 2W 12Vin 5Vout 400mA SIP Single Out

Manufacturer: Murata
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

35: USD 5.9413 ea
Line Total: USD 207.95

0 - Global Stock
MOQ: 35  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Tue. 30 Apr to Mon. 06 May

MOQ : 35
Multiples : 1

Stock Image

CRL2S1205SC
Murata

35 : USD 5.9413
105 : USD 5.4613
525 : USD 5.4

0 - Global Stock


Ships to you between Tue. 30 Apr to Mon. 06 May

MOQ : 35
Multiples : 35

Stock Image

CRL2S1205SC
Murata

35 : USD 6.1236
70 : USD 5.67
140 : USD 5.67
175 : USD 5.67
525 : USD 5.67

0 - Global Stock


Ships to you between Tue. 30 Apr to Mon. 06 May

MOQ : 35
Multiples : 35

Stock Image

CRL2S1205SC
Murata

35 : USD 8.4872

0 - Global Stock


Ships to you between Mon. 06 May to Wed. 08 May

MOQ : 1
Multiples : 1

Stock Image

CRL2S1205SC
Murata

1 : USD 7.0035
5 : USD 6.969
10 : USD 6.923
25 : USD 6.8425
35 : USD 6.325
105 : USD 5.934
280 : USD 5.9225

0 - Global Stock


Ships to you between Tue. 30 Apr to Mon. 06 May

MOQ : 3
Multiples : 1

Stock Image

CRL2S1205SC
Murata

3 : USD 7.514
9 : USD 7.111

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Output Power
Number of Outputs
Output Voltage-Channel 1
Output Current-Channel 1
Isolation Voltage
Mounting Style
Commercial/Medical
Height
Input Voltage
Length
Operating Temperature Range
Packaging
Product
Series
Width
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
Hot CRV1D0512SC electronic component of Murata CRV1D0512SC

Module DC-DC 5VIN 2-OUT 12V/-12V 0.042A/-0.042A 1W 5-Pin SIP Module Tube
Stock : 25

CRV1D1212SC electronic component of Murata CRV1D1212SC

Module DC-DC 12VIN 2-OUT 12V/-12V 0.042A/-0.042A 1W 5-Pin SIP Module Tube
Stock : 2

CRV1S0505SC electronic component of Murata CRV1S0505SC

Module DC-DC 5VIN 1-OUT 5V 0.2A 1W 4-Pin SIP Module Tube
Stock : 84

CRV1S1215SC electronic component of Murata CRV1S1215SC

Module DC-DC 12VIN 1-OUT 15V 0.067A 1W 4-Pin SIP Module Tube
Stock : 6

CRV2S0505SC electronic component of Murata CRV2S0505SC

Module DC-DC 5VIN 1-OUT 5V 0.4A 2W 4-Pin SIP Module Tube
Stock : 46

CSACW24M0X53-R0 electronic component of Murata CSACW24M0X53-R0

Resonators 24.00MHZ .5% CHIP RESONATOR
Stock : 0

CRR1S0505SC electronic component of Murata CRR1S0505SC

Isolated DC/DC Converters 1W 5Vin 5Vout 200mA SIP Single Out
Stock : 154

CSA12.00000-MHZ electronic component of Murata CSA12.00000-MHZ

12.00000MHZ 2PIN CERAMIC RESONATOR
Stock : 56

CSAC2.00MGCM-TC electronic component of Murata CSAC2.00MGCM-TC

Ceramic Resonator 22.579MHz ±0.5% (Tol) ±0.2% (Stability) 80Ohm T/R
Stock : 0

CSACW24M5X53R0 electronic component of Murata CSACW24M5X53R0

Murata Electronics Resonators 24.5MHz 5%
Stock : 0

Image Description
CRR1S0505SC electronic component of Murata CRR1S0505SC

Isolated DC/DC Converters 1W 5Vin 5Vout 200mA SIP Single Out
Stock : 154

RD-1205D/P electronic component of RECOM POWER RD-1205D/P

Isolated DC/DC Converters 2W DC/DC 1kV UNREG 12Vin +/-5Vout
Stock : 0

RDC20110D12 electronic component of XP Power RDC20110D12

Isolated Module DC DC Converter 2 Output 12V -12V 830mA, 830mA 55V - 176V Input
Stock : 3

RDC20110D15 electronic component of XP Power RDC20110D15

Isolated Module DC DC Converter 2 Output 15V -15V 670mA, 670mA 55V - 176V Input
Stock : 0

RDC2072D05 electronic component of XP Power RDC2072D05

Isolated Module DC DC Converter 2 Output 5V -5V 2A, 2A 36V - 140V Input
Stock : 0

RDC2072D15 electronic component of XP Power RDC2072D15

Isolated Module DC DC Converter 2 Output 15V -15V 670mA, 670mA 36V - 140V Input
Stock : 0

RDC2072S12 electronic component of XP Power RDC2072S12

Isolated Module DC DC Converter 1 Output 12V 1.65A 36V - 140V Input
Stock : 0

RDC2072S15 electronic component of XP Power RDC2072S15

Isolated Module DC DC Converter 1 Output 15V 1.33A 36V - 140V Input
Stock : 0

RDC30110S3V3 electronic component of XP Power RDC30110S3V3

Isolated Module DC DC Converter 1 Output 3.3V 7.5A 55V - 176V Input
Stock : 0

RDC30110T0312 electronic component of XP Power RDC30110T0312

Isolated Module DC DC Converter 3 Output 3.3V 12V -12V 5A, 420mA, 420mA 55V - 176V Input
Stock : 0

CRL2 Series www.murata-ps.com Isolated 2W Single Output DC/DC Converters SELECTION GUIDE Order Code MIL. Tel. V V mA % mVp-p % pF kHrs CRL2S0505SC 5 5 400 513 6 8 96 200 75 78 19 2327 CRL2S1205SC 12 5 400 207 4 5 76 200 77 81 28 716 FEATURES UL 60950 Recognised INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Wide temperature performance at full Continuous operation, 5V input types 4.5 5 5.5 2 Watt load, 40C to 85C Voltage range V Continuous operation, 12V input types 10.8 12 13.2 UL 94V-0 package material 5V input types 33 Reected ripple current mA p-p 12V input types 38 Single isolated output Industry standard pinout OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1kVDC isolation Hi Pot Test Rated Power TA=-40C to 85C 1.0 W 5V & 12V Input Voltage Set Point Accuracy See tolerance envelope Line regulation High VIN to low VIN 1.1 1.2 %/% 5V Output Fully encapsulated with toroidal ISOLATION CHARACTERISTICS magnetics Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 1000 VDC No external components required Resistance Viso= 1000VDC 10 G Pin compatible with CME, CRE1, LME, MEE1, MEE3, NKE, NME & NML series GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units No electrolytic or tantalum capacitors Switching frequency All input types 90 kHz PRODUCT OVERVIEW ABSOLUTE MAXIMUM RATINGS The CRL2 series of DC/DC Converters is particular- Lead temperature 1.5mm from case for 10 seconds 260C ly suited to isolating and/or converting DC power Input voltage VIN, 5V input 7V rails. The galvanic isolation allows the device to be Input voltage VIN, 12V input 15V congured to provide an isolated negative rail in systems where only positive rails exist. The wide TEMPERATURE CHARACTERISTICS temperature range guarantees startup from 40C Parameter Conditions Min. Typ. Max. Units and full 2 watt output at 85C. Pin compatibility Specication -40 85 with the NME and LME ensures ease of upgrade- Storage -50 130 ability.jjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjjj- C Case Temperature above 45 jjjjjjjjjjjjjj ambient Cooling Free air convection 1. See Ripple & Noise characterisation method. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support KDC CRL2.B01 Page 1 of 6 Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) 1 Ripple & Noise (Typ) 1 Ripple & Noise (Max) Efciency (Min) Efciency (Typ) Isolation Capacitance 2 MTTFCRL2 Series Isolated 2W Single Output DC/DC Converters TOLERANCE ENVELOPE The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. 0505: 1205: +6% +4% +3% +2% +1% 0% -2% -3% 100 75 100 10 25 50 75 10 25 50 Output Load Current (%) Output Load Current (%) TECHNICAL NOTES ISOLATION VOLTAGE Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand Voltage & Isolation Test Voltage are all terms that relate to the same thing, a test voltage, applied for a specied time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRL2 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation The CRL2 has been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRL2 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specied test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRL2 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum still air ambient temperature of 100C as measured at any point on the case of the unit (hotspot). The CRL2 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as dened below. CRL2x05xxxSC: 0.8A CRL2x12xxxSC: 0.315A All fuses should be UL recognised, 125V rated. File number E151252 applies. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260C for 10 seconds. The pin termination nish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs www.murata-ps.com/support KDC CRL2.B01 Page 2 of 6 Output Voltage Output Voltage

Tariff Desc

8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free
IPDiA
MU2
MUP
MUR
MURATA
Murata - TOKO
Murata / IPDiA
Murata Electronics
Murata Electronics N
Murata Electronics North America
MURATA MANUFACTURING
Murata Manufacturing Co.
Murata Power Solutio
Murata Power Solutions
Murata Power Solutions Inc
Murata Power Solutions Inc.
Toko
TOKO AMERICA
Toko America Inc.
TOKO, Inc.
TOKYO PARTS INDUSTRIAL
Tokyo Parts Industrial Group

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted