Product Information

CRE1S0505MEC

Product Image X-ON

Datasheet
Module DC-DC 5VIN 1-OUT 5V 0.2A 1W 5-Pin SMD Module Tube
Manufacturer: Murata


Price (Ex GST)

From 2.5554

68 - Global Stock
Ships to you between
Thu. 04 Mar to Wed. 10 Mar

MOQ: 39 Multiples:39
Pack Size :   39
Availability Price Quantity
10 - Global Stock


Ships to you between Thu. 04 Mar to Wed. 10 Mar

MOQ : 1
Multiples : 1
1 : $ 6.939

Buy
93 - Global Stock


Ships to you between Wed. 03 Mar to Fri. 05 Mar

MOQ : 1
Multiples : 1
1 : $ 9.5526
5 : $ 6.9158
10 : $ 6.8684
25 : $ 6.7895
50 : $ 6.6158
100 : $ 6.2842
250 : $ 5.8895
500 : $ 5.4947
1000 : $ 5.1474

Buy
10 - Global Stock


Ships to you between Thu. 04 Mar to Wed. 10 Mar

MOQ : 2
Multiples : 2
2 : $ 6.939

Buy
68 - Global Stock


Ships to you between Thu. 04 Mar to Wed. 10 Mar

MOQ : 39
Multiples : 39
39 : $ 2.5554

Buy
   
Manufacturer
Murata
Product Category
Isolated DC/DC Converters
Category
Isolated Dc/Dc Converters
Width
10.7 mm
LoadingGif
Image
Mfr. Part No.
Description
Stock
Isolated DC/DC Converters 1W 24Vin 5Vout 200mA SIP Single Out
189
Isolated DC/DC Converters 1W 24Vin 12Vout 83mA SIP Single Out
27
Module DC-DC 5VIN 1-OUT 5V 0.4A 2W 4-Pin Tube
14
Module DC-DC 5VIN 1-OUT 5V 0.2A 1W 4-Pin SIP Module Tube
1966
Module DC-DC 5VIN 1-OUT 15V 0.067A 1W 4-Pin SIP Module Tube
10
Module DC-DC 12VIN 1-OUT 5V 0.2A 1W 4-Pin SIP Module Tube
5
Module DC-DC 12VIN 1-OUT 12V 0.083A 1W 4-Pin SIP Module Tube
346
Module DC-DC 5VIN 1-OUT 5V 0.2A 1W 4-Pin SIP Module Tube
94
Isolated 1W Single Output Isolated DC/DC Converter
73
Image
Mfr. Part No.
Description
Stock
Isolated DC/DC Converters DC-DC Converter, 15 Watt, 4:1 Input Range, 9-36VDC Input, +/-15VDC Output
4
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 16A 80W 7-Pin T/R
134
Module DC-DC 12VIN 1-OUT 5V 1.5A 7.5W 3-Pin
589
Isolated DC/DC Converters 5W DC/DC 2kV REG 4:1 9-36Vin 12Vout
21
Isolated DC/DC Converters 15W 5V 3A
9
Isolated DC/DC Converters VI-N53-CM 150V/24V 600W
3
Isolated DC/DC Converters Valued added PS
2
Isolated DC/DC Converters 6W DC/DC 10kV REG 5Vin 5Vout
19

CRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series Isolated 1W Single Output Isolated DC-DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260?C Input voltage VIN, 3.3V input 5.5V Input voltage VIN, 5V input 7V Input voltage VIN, 12V input 15V Input voltage VIN, 24V input 28V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1 -40 85 Specification All output types Storage -50 130 5V output types 41 ?C Case temperature rise above All other output types 32 ambient CRE1S0505MC 43 CRE1S0505MEC 12.5 Cooling Free air convection TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRE1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1 second for 3C versions. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The CRE1 series, through hole variants (excluding surface mount variants) have been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRE1 series has been recognised by Underwriters Laboratory (UL) to UL60950 for functional insulation in a maximum still air ambient temperature of 100?C for the C versions and 130?C for the 3C versions as measured on the case of the unit (hotspot). The CRE1S0505MC is not currently UL recognised. The CRE1 series of converters are not internally fused so to meet the requirements of UL60950 an anti-surge input line fuse should always be used with ratings as defined belo w. CRE1S03xxS3C: 1A CRE1S05xxxxC: 0.7A CRE1S12xxSC: 0.2A CRE1S24xxSC: 0.16A All fuses should be UL recognised, 125V rated. File number E151252 applies. 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 2 of 14CRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series Isolated 1W Single Output Isolated DC-DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260?C Input voltage VIN, 3.3V input 5.5V Input voltage VIN, 5V input 7V Input voltage VIN, 12V input 15V Input voltage VIN, 24V input 28V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1 -40 85 Specification All output types Storage -50 130 5V output types 41 ?C Case temperature rise above All other output types 32 ambient CRE1S0505MC 43 CRE1S0505MEC 12.5 Cooling Free air convection TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRE1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1 second for 3C versions. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The CRE1 series, through hole variants (excluding surface mount variants) have been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRE1 series has been recognised by Underwriters Laboratory (UL) to UL60950 for functional insulation in a maximum still air ambient temperature of 100?C for the C versions and 130?C for the 3C versions as measured on the case of the unit (hotspot). The CRE1S0505MC is not currently UL recognised. The CRE1 series of converters are not internally fused so to meet the requirements of UL60950 an anti-surge input line fuse should always be used with ratings as defined belo w. CRE1S03xxS3C: 1A CRE1S05xxxxC: 0.7A CRE1S12xxSC: 0.2A CRE1S24xxSC: 0.16A All fuses should be UL recognised, 125V rated. File number E151252 applies. 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 2 of 14CRE1 Series Isolated 1W Single Output Isolated DC-DC Converters 1 TEMPERATURE DERATING GRAPH - Surface Mount & 3C types TEMPERATURE DERATING GRAPH - All other types 85?C 85?C 1.0 1.0 Safe Operating Area Safe Operating Area 120?C 0 0 -40 0 50 100 150 -40 0 50 100 150 Ambient Temperature (?C) Ambient Temperature (?C) EFFICIENCY VS LOAD 3.3V Inputs 5V Inputs CRE1S0305S3C 90 90 80 80 70 70 60 60 CRE1S0505XC 50 50 CRE1S0515SC CRE1S0305S3C CRE1S0505S3C 40 40 CRE1S0505MC CRE1S0505MEC 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) 12V Inputs 24V Inputs 90 90 80 80 70 70 60 60 CRE1S2405SC 50 50 CRE1S1205SC 40 40 CRE1S2412SC CRE1S1212SC 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 3 of 14 Efficiency (%) Efficiency (%) Output Power (W) Output Power (W) Efficiency (%) Efficiency (%)CRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series Isolated 1W Single Output Isolated DC-DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260?C Input voltage VIN, 3.3V input 5.5V Input voltage VIN, 5V input 7V Input voltage VIN, 12V input 15V Input voltage VIN, 24V input 28V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1 -40 85 Specification All output types Storage -50 130 5V output types 41 ?C Case temperature rise above All other output types 32 ambient CRE1S0505MC 43 CRE1S0505MEC 12.5 Cooling Free air convection TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRE1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1 second for 3C versions. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The CRE1 series, through hole variants (excluding surface mount variants) have been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRE1 series has been recognised by Underwriters Laboratory (UL) to UL60950 for functional insulation in a maximum still air ambient temperature of 100?C for the C versions and 130?C for the 3C versions as measured on the case of the unit (hotspot). The CRE1S0505MC is not currently UL recognised. The CRE1 series of converters are not internally fused so to meet the requirements of UL60950 an anti-surge input line fuse should always be used with ratings as defined belo w. CRE1S03xxS3C: 1A CRE1S05xxxxC: 0.7A CRE1S12xxSC: 0.2A CRE1S24xxSC: 0.16A All fuses should be UL recognised, 125V rated. File number E151252 applies. 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 2 of 14CRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series www.murata-ps.com Isolated 1W Single Output Isolated DC-DC Converters SELECTION GUIDE % mV p-p % MIL. Tel. V V mA mA pF Typ. Max. Typ. Max. Min. Typ. kHrs CRE1S0505DC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0505SC 5 5 200 12 14 16 40 286 65 70 30 CRE1S0515SC 5 15 67 6 7.5 10 25 250 77 80 40 FEATURES CRE1S1205SC 12 5 200 8 10 12 30 117 68 71 33 3 UL 60950 recognised n CRE1S1212SC 12 12 83 4 5 8 20 104 75 80 55 CRE1S2405SC 24 5 200 8.5 10 13 30 58 67 71 40 Single Isolated output n CRE1S2412SC 24 12 83 3 4 10 25 52 75 80 78 1kVDC or 3kVDC option ?Hi Pot Test? n 3KVDC isolation options CRE1S0305S3C 3.3 5 200 10 12 15 25 400 72 75 35 Wide temperature performance at full n 4 CRE1S0505S3C 5 5 200 6 8 15 25 250 73 77 24 1W load -40?C to 85?C n Surface mount options Industry Standard Pinout n CRE1S0505MC 5 5 200 12.8 15 62 85 294 68 35 6857 CRE1S0505MEC 5 5 200 6.5 8 25 70 239 79 82 22 3041 3.3V, 5V, 12V & 24V Inputs n INPUT CHARACTERISTICS 5V, 12V & 15V outputs n Parameter Conditions Min. Typ. Max. Units Pin Compatible with CME, CRL2, LME, n Continuous operation, 3.3V input types 2.97 3.3 3.63 V MEE1, MEE3, MTE1, NKE, NME, NML & Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range NTE series Continuous operation, 12V input types 10.8 12 13.2 Continuous operation, 24V input types 21.6 24 26.4 Through hole and surface mount options n 3.3V & 12V input types 1 15 available n 5V & 24V input types 2 15 Reflected ripple current mA p-p CRE1S0505MC 30 47 PRODUCT OVERVIEW CRE1S0505MEC 5 15 The CRE1 series are a cost effective 1W DC-DC converter series, in industry standard packages OUTPUT CHARACTERISTICS with industry standard pinout. Popular input Parameter Conditions Min. Typ. Max. Units and output voltages are available. The galvanic 3 Rated Power TA=-40?C to 85?C 1 W isolation allows the device to be configured to Voltage Set Point Accuracy See tolerance envelope provide an isolated negative rail in systems where Line regulation High VIN to low VIN 1.1 1.2 %/% only positive rails exist. The wide temperature range guarantees startup from ?40?C and full 1 ISOLATION CHARACTERISTICS 3 watt output at 85?C . Parameter Conditions Min. Typ. Max. Units C Versions Flash tested for 1 second 1000 Isolation test voltage VDC 3C Versions Flash tested for 1 second 3000 Resistance Viso= 1000VDC 10 G? GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 3.3V input types 115 5V input types 110 kHz Switching frequency 12V input types 145 24V input types 100 CRE1S0505MEC 80 1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R. 2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 3. UL 60950 recognition does not apply to CRE1S0505MC. 4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. For full details go to www.murata-ps.com/rohs All specifications typical at T A=25?C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_CRE1.D02 Page 1 of 14 1 Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation Ripple & Noise Input Current at Rated Load Efficiency Isolation Capacitance 2 MTTFCRE1 Series Isolated 1W Single Output Isolated DC-DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds 260?C Input voltage VIN, 3.3V input 5.5V Input voltage VIN, 5V input 7V Input voltage VIN, 12V input 15V Input voltage VIN, 24V input 28V TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 1 -40 85 Specification All output types Storage -50 130 5V output types 41 ?C Case temperature rise above All other output types 32 ambient CRE1S0505MC 43 CRE1S0505MEC 12.5 Cooling Free air convection TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions CRE1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1 second for 3C versions. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The CRE1 series, through hole variants (excluding surface mount variants) have been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The CRE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The CRE1 series has been recognised by Underwriters Laboratory (UL) to UL60950 for functional insulation in a maximum still air ambient temperature of 100?C for the C versions and 130?C for the 3C versions as measured on the case of the unit (hotspot). The CRE1S0505MC is not currently UL recognised. The CRE1 series of converters are not internally fused so to meet the requirements of UL60950 an anti-surge input line fuse should always be used with ratings as defined belo w. CRE1S03xxS3C: 1A CRE1S05xxxxC: 0.7A CRE1S12xxSC: 0.2A CRE1S24xxSC: 0.16A All fuses should be UL recognised, 125V rated. File number E151252 applies. 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 2 of 14CRE1 Series Isolated 1W Single Output Isolated DC-DC Converters 1 TEMPERATURE DERATING GRAPH - Surface Mount & 3C types TEMPERATURE DERATING GRAPH - All other types 85?C 85?C 1.0 1.0 Safe Operating Area Safe Operating Area 120?C 0 0 -40 0 50 100 150 -40 0 50 100 150 Ambient Temperature (?C) Ambient Temperature (?C) EFFICIENCY VS LOAD 3.3V Inputs 5V Inputs CRE1S0305S3C 90 90 80 80 70 70 60 60 CRE1S0505XC 50 50 CRE1S0515SC CRE1S0305S3C CRE1S0505S3C 40 40 CRE1S0505MC CRE1S0505MEC 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) 12V Inputs 24V Inputs 90 90 80 80 70 70 60 60 CRE1S2405SC 50 50 CRE1S1205SC 40 40 CRE1S2412SC CRE1S1212SC 30 30 20 20 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Load (%) Load (%) 1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70?C. www.murata-ps.com/support KDC_CRE1.D02 Page 3 of 14 Efficiency (%) Efficiency (%) Output Power (W) Output Power (W) Efficiency (%) Efficiency (%)

Tariff Concession Code
Tariff Desc

9601650
8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free
MU2
MUP
MUR
MURATA
Murata - TOKO
Murata Electronics
Murata Electronics N
Murata Electronics North America
MURATA MANUFACTURING
Murata Power Solutio
Murata Power Solutions
Murata Power Solutions Inc
Murata Power Solutions Inc.