Product Information

NDY1212

NDY1212 electronic component of Murata

Datasheet
NDY1212 DC/DC CONVERTER

Manufacturer: Murata
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 26.7827 ea
Line Total: USD 26.78

8 - Global Stock
Ships to you by
Fri. 26 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
8 - Global Stock


Ships to you by Fri. 26 Apr

MOQ : 1
Multiples : 1

Stock Image

NDY1212
Murata

1 : USD 26.7827
5 : USD 25.2948
10 : USD 23.8068
20 : USD 20.831
50 : USD 18.5991

     
Manufacturer
Product Category
Output Power
Number of Outputs
Output Voltage-Channel 1
Output Current-Channel 1
Isolation Voltage
Package / Case Size
Input Voltage
Packaging
Product
Series
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
22R473 electronic component of Murata 22R473

22R473 47UH INDUCTOR
Stock : 0

45104C electronic component of Murata 45104C

Fixed Inductors 100uH 0.70A SMT
Stock : 3394

45105C electronic component of Murata 45105C

Murata Power Solutions Fixed Inductors 1000uH 0.23A SMT
Stock : 1156

45152C electronic component of Murata 45152C

Murata Power Solutions Fixed Inductors 1.5uH 5.5A SMT
Stock : 1000

45153C electronic component of Murata 45153C

Fixed Inductors 15uH 1.8A SMT
Stock : 808

45154C electronic component of Murata 45154C

Murata Power Solutions Fixed Inductors 150uH 0.58A SMT
Stock : 98

22R105 electronic component of Murata 22R105

22R105 1MH INDUCTOR
Stock : 0

18R225 electronic component of Murata 18R225

18R225 2.2MH RAD INDUCTOR
Stock : 0

45102C electronic component of Murata 45102C

Murata Power Solutions Fixed Inductors 1.0uH 6.0A SMT
Stock : 1000

45103C electronic component of Murata 45103C

Fixed Inductors 10uH 2.2A SMT
Stock : 55

Image Description
TLE6368G2 electronic component of Infineon TLE6368G2

Voltage Regulators - Switching Regulators DC/DC CONVERTER
Stock : 5269

449-2071-000 electronic component of ITT 449-2071-000

Circular MIL Spec Connector
Stock : 0

449-2075-101 electronic component of ITT 449-2075-101

D-Sub Standard Connectors
Stock : 50

449-2077-000 electronic component of ITT 449-2077-000

Circular MIL Spec Connector
Stock : 0

MDCM270P120M500A40 electronic component of Vicor MDCM270P120M500A40

Isolated DC/DC Converters 270VIN MDCM DC/DC Converter 12VOUT500W
Stock : 4

MDCM270P280M500A40 electronic component of Vicor MDCM270P280M500A40

Isolated DC/DC Converters 270VIN MDCM DC/DC Converter 28VOUT500W
Stock : 0

MDCM28AP150M320A50 electronic component of Vicor MDCM28AP150M320A50

Isolated DC/DC Converters 28VIN MDCM DC/DC Converter 15VOUT320W
Stock : 1

MDCM28AP480M320A50 electronic component of Vicor MDCM28AP480M320A50

Isolated DC/DC Converters 28VIN MDCM DC/DC Converter 48VOUT320W
Stock : 0

AUR9707AGD electronic component of Diodes Incorporated AUR9707AGD

Switching Voltage Regulators Dual High EFF PWM DC/DC Conv 1A 600mV
Stock : 276

AVD100-48S05-6L electronic component of Artesyn Embedded Technologies AVD100-48S05-6L

Isolated DC/DC Converters 100W 36-75Vin 5V@20A 3.8mm Pin
Stock : 192

NDY Series www.murata-ps.com Isolated 3W Wide Input DC/DC Converters SELECTION GUIDE Output current 3 MTTF Min. Order code Full load 1 Load V (Nom.) V mA mA mA % pF kHrs NDY0505C 5 5 100-150 400-600 615 66 40 1939 NDY0509C 5 9 55-83 222-333 563 72 52 1926 NDY0512C 5 12 42-62 166-250 548 71 43 1907 FEATURES NDY0515C 5 15 33-50 133-200 533 73 44 1924 UL 60950 recognised NDY1205C 12 5 150 600 362 71 36 1928 NDY1209C 12 9 83 333 320 78 52 1916 Industry standard footprint NDY1212C 12 12 62 250 316 78 44 1897 Efciency to 82% NDY1215C 12 15 50 200 308 79 47 1914 NDY2403C 24 3.3 227 909 178 70 30 1671 1kVDC Isolation Hi Pot Test NDY2405C 24 5 150 600 174 70 36 1673 2:1 wide input range NDY2409C 24 9 83 333 156 78 52 1663 Single isolated output NDY2412C 24 12 62 250 154 80 44 1644 NDY2415C 24 15 50 200 150 82 54 1657 Short circuit protection NDY4805C 48 5 150 600 87 73 35 1668 Low prole 24 pin case Recommended Alternative Operating temperature range -40C to 85C NDY4803C 48 3.3 227 909 87 71 30 1676 NCS3S4803SC 5V, 12V, 24V & 48V input NDY4809C 48 9 83 333 78 80 52 1663 Contact Murata NDY4812C 48 12 62 250 77 81 44 1648 NCS3S4812SC 3.3V, 5V, 9V, 12V & 15V output NDY4815C 48 15 50 200 76 81 53 1661 NCS3S4815SC Internal SMD construction INPUT CHARACTERISTICS Fully encapsulated Parameter Conditions Min. Typ. Max. Units All NDY05XX 4.5 5 9 DESCRIPTION All NDY12XX 9 12 18 The NDY series is a range of low prole DC/DC Voltage range VDC All NDY24XX 18 24 36 converters offering a single regulated output over a All NDY48XX 36 48 72 2:1 input voltage range. All parts deliver 3W output NDY2403 180 360 power up to 85C without heatsinking, except the NDY4803 140 290 4.5V to 9V input voltage range which should be All NDY05XX 400 500 derated to 2W at the lower input voltage. A yback 2 Reected ripple current mA p-p All NDY12XX 150 170 oscillator design with isolated feedback is used to All other NDY24XX 290 360 give regulation over the full operating range of 25% to 100% of full load. It is strongly recommended All other NDY48XX 100 127 that external capacitors be used on input and output to guarantee performance over full load and ABSOLUTE MAXIMUM RATINGS input voltage range. Short-circuit protection Continuous Lead temperature 1.5mm from case for 10 seconds 300C Minimum load 25% of rated load Input voltage 05 types 10V Input voltage 12 types 20V Input voltage 24 types 40V Input voltage 48 types 80V Internal dissipation 1.7W 1. Refer to power derating graph. 2. Measured at full load with external input/output capacitors, refer to lter circuit 1. 3. Calculated using MIL-HDBK-217F with nominal input voltage at full load (ground benign) at 25C. For full details go to All specications typical at TA=25C, nominal input voltage and rated output current unless otherwise specied. www.murata-ps.com/rohs www.murata-ps.com/support KDC NDY.G01 Page 1 of 4 Input voltage Rated output voltage Input current full load 2 Efciency (Min.) Isolation capacitanceNDY Series Isolated 3W Wide Input DC/DC Converters OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage set point accuracy With external input/output capacitors 1 5 % Low line to high line, 3.3V output with external input/output capacitors 0.05 0.25 % Line regulation Low line to high line, all other outputs with external input/output capacitors 0.05 0.5 % 25% load to 100% load, 3.3V output with external input/output capacitors 0.6 1.0 % Load regulation 25% load to 100% load, all other outputs with external input/output capacitors 0.2 0.5 % BW = 20Hz to 300kHz, 3.3V output with external input/output capacitors 80 120 1 Ripple mV rms BW = 20Hz to 300kHz, all other outputs with external input/output capacitors 5 10 BW = DC to 100MHz, 3.3V output with external input/output capacitors 180 1 Noise mV p-p BW = DC to 20MHz, all other outputs with external input/output capacitors 50 100 GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units 100% load VIN nominal 3.3V output 160 220 25% load VIN nominal 3.3V output 290 560 Switching frequency kHz 100% load VIN nominal, all other outputs 80 220 25% load VIN nominal, all other outputs 290 560 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operation Ambient temperature -40 85 C Storage -50 130 Cooling Free air convection ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 1000 VDC Resistance Viso=500VDC 1 G TECHNICAL NOTES ISOLATION VOLTAGE Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand Voltage & Isolation Test Voltage are all terms that relate to the same thing, a test voltage, applied for a specied time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NDY series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation The NDY series has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NDY series has an EI ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specied test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The NDY series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation for a maximum case temperature limit of 130C (case temperature measured on the face opposite the pins). File number E151252 applies. Note: This series gained UL 60950 recognition for products manufactured on or after datecode G1123, any NDY parts manufactured before this date code should not be considered UL 60950 recognized. Any NDY that is UL recognized will be printed with the UL logo. 1. For lower ripple refer to circuit for reduced ripple. www.murata-ps.com/support KDC NDY.G01 Page 2 of 4

Tariff Desc

8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free
IPDiA
MU2
MUP
MUR
MURATA
Murata - TOKO
Murata / IPDiA
Murata Electronics
Murata Electronics N
Murata Electronics North America
MURATA MANUFACTURING
Murata Manufacturing Co.
Murata Power Solutio
Murata Power Solutions
Murata Power Solutions Inc
Murata Power Solutions Inc.
Toko
TOKO AMERICA
Toko America Inc.
TOKO, Inc.
TOKYO PARTS INDUSTRIAL
Tokyo Parts Industrial Group

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted