Datasheet
TIME DELAY RELAY, DPDT, 1S-10S, 240V

Manufacturer: Macromatic
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 133.305 ea
Line Total: USD 133.305

3 - Global Stock
Ships to you between
Thu. 04 Apr to Wed. 10 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
3 - Global Stock


Ships to you between Thu. 04 Apr to Wed. 10 Apr

MOQ : 1
Multiples : 1

Stock Image

TR-6152U
Macromatic

1 : USD 137.5369
5 : USD 120.1069
10 : USD 113.7019
25 : USD 107.94

     
Manufacturer
Product Category
Brand
Contact Voltage Vdc
Time Min
Time Max
Product Range
Contact Configuration
Contact Current
Relay Mounting
Contact Voltage Vac
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
ARP120A3R electronic component of Macromatic ARP120A3R

RELAY, DPDT, 240VAC, 30VDC, 10A
Stock : 6

TAA1U electronic component of Macromatic TAA1U

TIME DELAY RELAY
Stock : 3

TD-78122 electronic component of Macromatic TD-78122

TIME DELAY RELAY, DPDT, 999H, 240VAC
Stock : 13

TD-78128 electronic component of Macromatic TD-78128

TIME DELAY RELAY, DPDT, 999H, 240VAC
Stock : 5

TR-60622 electronic component of Macromatic TR-60622

TIME DELAY RELAY, DPDT, 30MIN, 240VAC
Stock : 1

TR-50222-05 electronic component of Macromatic TR-50222-05

TIME DELAY RELAY, DPDT, 10S, 240VAC
Stock : 3

TR-6052U electronic component of Macromatic TR-6052U

TIME DELAY RELAY, DPDT, 0.1S-1S, 240V
Stock : 5

TR-6162U electronic component of Macromatic TR-6162U

TIME DELAY RELAY, DPDT, 0.5S-5S, 240V
Stock : 2

TR-6192U electronic component of Macromatic TR-6192U

TIME DELAY RELAY, DPDT, 0.5S-5S, 240V
Stock : 4

TR-6512U electronic component of Macromatic TR-6512U

TIME DELAY RELAY, DPDT, 0.05S-100H, 240V
Stock : 1

Image Description
6NO120B electronic component of Amperite 6NO120B

Electromechanical Relay 6VDC 6VAC 3A SPST-NO (42.8x28.57)mm Panel Time Delay Relay
Stock : 1

FS126-60 electronic component of SSAC FS126-60

Time Delay & Timing Relays ACLOWCOSTFLASHER
Stock : 1

24DF90D electronic component of Amperite 24DF90D

24DF90D amperite
Stock : 1

FS126RC-45 electronic component of SSAC FS126RC-45

Flasher 120VAC 1A 45fpm Inductive load 6 inch wires
Stock : 1

CDR701CHQPN24D electronic component of TE Connectivity CDR701CHQPN24D

CDR701CHQPN24D te connectivity
Stock : 1

115C15B electronic component of Amperite 115C15B

Electromechanical Relay 115VDC 115VAC 3A SPST-NC (42.8x28.57)mm Panel Time Delay Relay
Stock : 0

QCS20M110AL electronic component of Crouzet QCS20M110AL

Time Delay & Timing Relays TMR 11
Stock : 1

SHS180S24A electronic component of Crouzet SHS180S24A

Time Delay & Timing Relays 180S, 24VAC SS TIMR INTERVAL
Stock : 1

GE1A-B10HA220 electronic component of Idec GE1A-B10HA220

Timer; 0,1s÷10h; SPDT + SPDT; 240VAC/5A,24VDC/5A; 220÷240VAC
Stock : 7

115C5B electronic component of Amperite 115C5B

Electromechanical Relay 115VDC 115VAC 3A SPST-NC (42.8x28.57)mm Panel Time Delay Relay
Stock : 1

time delay relays plug-in PROGRAMMABLE MULTI-RANGE OFF DELAY, SINGLE SHOT & WATCHDOG tm TR-6 Series Time Ranger The TR-6 Series offers the exible programmability of a multi-range time delay relay together with a universal input voltage. These products provide an easy method to select one of 16 time ranges between 0.05 seconds and 100 hours using a rotary switch. The actual time delay is then set by using the potentiometer to adjust within the selected time range. INPUT CATALOG FUNCTION VOLTAGE WIRING/SOCKETS NUMBER 50/60Hz.. 24-240V AC & TR-6162U 11 PIN OCTAL OFF DELAY 12-125V DC 70170-D Control Switch Trigger Each unit has 16 timing ranges built-in covering 0.05 seconds-100 SINGLE SHOT 24-240V AC & TR-6152U hours Control Switch Trigger 12-125V DC Selecting a range is easy using a rotary switch (no math is required WATCHDOG 24-240V AC & TR-6132U or DIP switches to set) Control Switch Trigger 12-125V DC (Retriggerable Single Shot) Universal input voltage: 24-240V AC & 12-125V DC DIAGRAM 212 Uses industry-standard 11 pin OFF DELAY 24-240V AC & TR-6192U 8 PIN OCTAL octal sockets Power Trigger 12-125V DC 70170-D 10A DPDT output contacts can handle most pilot duty & fractional SINGLE SHOT 24-240V AC & TR-6172U HP loads Power Trigger 12-125V DC WATCHDOG 24-240V AC & TR-6182U Power Trigger 12-125V DC (Retriggerable Single Shot) DIAGRAM 216 See De nitions of Timing Functions. See TR-606 Series for True Off Delay function. Timing Ranges Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit (see below) and then adjust within that range using the knob on top. Dial Setting Timing Range A 0.05 - 0.5 Sec. B 0.1 - 1 Sec. C 0.5 - 5 Sec. D 1 - 10 Sec. E 3 - 30 Sec. F 6 - 60 Sec. G 0.2 - 2 Min. H 0.5 - 5 Min. I 1 - 10 Min. J 3 - 30 Min. K 6 - 60 Min. L 0.2 - 2 Hr. M 0.5 - 5 Hr. N 1 - 10 Hr. O 2.4 - 24 Hr. P 10 - 100 Hr. 800.238.7474 Sockets & Accessories available www.macromatic.com sales macromatic.com Build your Time Delay Relays with the Online Product Builder 29time delay relays plug-in PROGRAMMABLE MULTI-RANGE tm TR-6 Series Time Ranger Application Data Voltage Tolerance: Triggering Off Delay, Single Shot or Watchdog Units: AC Operation: 20.4 264V at 50/60 Hz Timing sequence must be initiated only after input voltage is DC Operation: 10.2 137.5V applied to unit. Minimum required trigger switch closure time is 0.1 seconds. Load (Burden): Maximum of 3 VA for all voltages Compatibility: Using a solid state switch to initiate the time sequence is Setting Accuracy: acceptable. See www.macromatic.com/leakage or contact Maximum Setting (Adjustable): +5%, -0% Macromatic for information regarding leakage current limits and Minimum Setting (Adjustable): +0%, -50% other solid state design considerations. Repeat Accuracy (constant voltage and temperature): Output Contacts: +0.1% or +50ms, whichever is greater DPDT 10A 240V AC/30V DC, Reset Time: 1/2HP 120/240V AC (N.O.), 1/3HP 120/240V AC (N.C.) Functions Triggered with Input Voltage: 0.1 Seconds B300 & R300 (N.O.) AC15 & DC13 Functions Triggered with Control Switch: 0.04 Seconds Life: Start-up Time: Mechanical: 10,000,000 operations (Time from when power is applied until unit is timing) Full Load: 100,000 operations 0.05 Seconds Approvals: Maintain Function Time: Low Voltage & File E109466 (Time unit continues to operate after power is removed) EMC Directives 0.01 Seconds EN60947-1, EN60947-5-1 Temperature: o o o o Operating: -28 to 65 C (-18 to 150 F) o o o o Storage: -40 to 85 C (-40 to 185 F) Dimensions TR-602, TR-605, TR608, TR609, TR-613, TR-615, TR-616, TR-631-TR-651, TR-661 & TR-665 TR-617, TR-618 & TR-619 All Dimensions in Inches (Millimeters) 800.238.7474 www.macromatic.com sales macromatic.com 31

Tariff Desc

9107.00.00 24 No TIME SWITCHES WITH CLOCK OR WATCH MOVEMENT OR WITH SYNCHRONOUS MOTOR TC 0711826 TIMERS, DIGITAL

9107.00.00 24 No TIME SWITCHES WITH CLOCK OR WATCH MOVEMENT OR WITH SYNCHRONOUS MOTOR TC 0306131 TIMERS, ELECTROMECHANICAL

8538.90.90 - - - 08 .. For programmable controllers Other Free
MACROMATIC CONTROLS
Macromatic Industrial Controls

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted