Product Information

DTM 995B

DTM 995B electronic component of Lascar

Datasheet
PANEL DISPLAY, THERMOCOUPLE, LCD, 7.5V TO 30V

Manufacturer: Lascar
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 92.6813 ea
Line Total: USD 92.6813

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1

Stock Image

DTM 995B
Lascar

1 : USD 195.1506

0 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1

Stock Image

DTM 995B
Lascar

1 : USD 186.9459
5 : USD 171.0474
10 : USD 167.8556

0 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1

Stock Image

DTM 995B
Lascar

1 : USD 92.6813

     
Manufacturer
Product Category
Brand
No. Of Digits / Alpha
Meter Function
Meter Range
Digit Height
Panel Cutout Height
Panel Cutout Width
Supply Voltage Min
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
EL-USB-1-PRO electronic component of Lascar EL-USB-1-PRO

Logger: temperature; -40÷125°C; IP67; Equipment: battery, software
Stock : 0

DPM950 electronic component of Lascar DPM950

Panel DC voltage meter; LCD 3,5 digit 19mm, with a backlit
Stock : 0

DPM 742-BL electronic component of Lascar DPM 742-BL

INDICATOR, LCD, 3.5DIGIT, 0-1000NOM
Stock : 0

DPM 40 electronic component of Lascar DPM 40

Voltmeter LED - Red Characters Display Panel Mount
Stock : 0

DPM 2000 electronic component of Lascar DPM 2000

DPM, LCD, 3.5DIGIT
Stock : 0

EL-USB-5+ electronic component of Lascar EL-USB-5+

DATA LOGGER, STATE CHANGE & COUNTER, 2HZ; Data Logger Type:USB Event, Count & State change; No. of Channels:-; Reading Capacity:1007616; Product Range:EL-USB Series; SVHC:No SVHC (27-Jun-2018)
Stock : 0

EL-MOTE-T electronic component of Lascar EL-MOTE-T

WIFI TEMP DATA LOGGER, -20 TO +60 DEGC; Data Logger Type:WiFi Temperature; No. of Channels:1Channels; Reading Capacity:-; Product Range:EL-MOTE Series; SVHC:No SVHC (27-Jun-2018)
Stock : 0

EL-MOTE-TP electronic component of Lascar EL-MOTE-TP

WIFI TEMP DATA LOGGER, -40 TO +125 DEGC; Data Logger Type:WiFi Temperature; No. of Channels:1Channels; Reading Capacity:-; Product Range:EL-MOTE Series; SVHC:No SVHC (27-Jun-2018)
Stock : 0

EL-MOTE-DTP electronic component of Lascar EL-MOTE-DTP

WIFI TEMP DATA LOGGER, -40 TO +125 DEGC; Data Logger Type:WiFi Temperature; No. of Channels:2Channels; Reading Capacity:-; Product Range:EL-MOTE Series; SVHC:No SVHC (27-Jun-2018)
Stock : 1

EL-P-TC-K-SPIKE electronic component of Lascar EL-P-TC-K-SPIKE

Probe: K-type temperature; Temp: -100÷700°C; Len: 1m
Stock : 1

Image Description
ACM20-2-AC1-R-F-C electronic component of Murata ACM20-2-AC1-R-F-C

Digital Panel Meters 10A 85-264Vac Supply Frequency Reading
Stock : 1

25.330.0453.1 electronic component of Wieland 25.330.0453.1

Terminal Block Plug - Type 8113S/G - 5mm Pitch - 4 Position - Vertical - Marked - Volume (CM3): 23.900
Stock : 1

25.521.3253.0 electronic component of Wieland 25.521.3253.0

Terminal Strip For PCB - 2.5mm2 - 5.00mm - 2 Poles
Stock : 1

DMS-20PC-3-GS-C electronic component of Murata DMS-20PC-3-GS-C

Digital Panel Meters 3.5 Digit +-200V Std Green
Stock : 18

DMS-EB-C electronic component of Murata DMS-EB-C

Digital Panel Meters Multipurpose board for DMS-30/40 meters
Stock : 1

DMS-20LCD-1-DCM-C electronic component of Murata DMS-20LCD-1-DCM-C

Digital Panel Meters +8.0 to 50.0Vdc
Stock : 510

4400-01032-0 electronic component of Murata 4400-01032-0

Murata Power Solutions Digital Panel Meters Crimp terminal for 12pin DMS Series
Stock : 1

DMS-40PC-1-GS-C electronic component of Murata DMS-40PC-1-GS-C

Digital Panel Meters 4.5 Digit +-2V Input Std Green
Stock : 131

LE-01 electronic component of F&F LE-01

Electric energy meter; analogue,mounting; single-phase; Inom: 5A
Stock : 3

LE-01M electronic component of F&F LE-01M

Electric energy meter; digital,mounting; for DIN rail mounting
Stock : 2

DTM 995B LCD Thermocouple ORDERING INFORMATION Indicator Standard Instrument DTM 995B (panel meter, fixing kit, data sheet) FEATURES Measures temperature from a K, J or T-type thermocouple -200 to +1300C (-328 to +1999F) measurement range Cold-junction compensation Displays current, highest and lowest readings 19mm (0.75) digit height Screw terminal connections LED backlighting The DTM 995B is compatible with K, J and T type thermocouples. It can measure between -200 and +1300C (-328 to +1999F) when using an appropriate thermocouple. The current value and the maximum and minimum values since power-on are recorded, which can be recalled and displayed by using an external push button connected to the meter. Calibration can be performed easily using two potentiometers located on the rear of the meter. Cold-junction compensation is used to maintain accuracy when the meter is exposed to changes in temperature. The meter is housed in a robust carrier, which can be bolted in place or panel mounted using the low profile bezel, window and clips provided. Backlighting is fitted for use in poor lighting conditions. SPECIFICATIONS Minimum Typical Maximum Unit 1 (2) Accuracy (excluding probe) C (F) Thermocouple measurement range (K-type) -200 (-328) +1300 (+1999) C (F) Thermocouple measurement range (J-type) -130 (-202) +900 (+1652) C (F) Thermocouple measurement range (T-type) -200 (-328) +350 (+662) C (F) Supply voltage (normal operation)* 7.5 V d.c. 30 4.75 5 Supply voltage (5V mode)* 5.25 V d.c. 5 Backlight voltage** 4.75 5.25 V d.c. Supply current 6mA ( 30V) 13mA ( 5V) mA Supply current with backlighting** 20mA ( 30V) 50mA ( 5V) mA Operating temperature range 0 (32) 50 (122) C (F) Temperature stability C/C (F/F) 0.05 (0.1) * A 5V mode is available by moving DIP switch 2 to the on position. Inputting a voltage larger than 5V in this mode may cause permanent damage to the meter. ** Backlighting can be run off the internal voltage regulator by moving DIP switch 1 to the on position. Using the backlighting in this way will cause some self heating of the meter. This can be calibrated out during initial setup, however the final application will need to continue using the backlighting to maintain the calibration. www.lascarelectronics.com Specifications liable to change without prior warning Issue 2 06/2010 S.L Applies to DTM 995B Page 1 of 3DTM 995B LCD Thermocouple Indicator CALIBRATION PROCEEDURE It is recommended that the DTM 995B is calibrated with a matched probe to achieve the most accurate readings. Calibration uses two known temperatures to adjust the span and offset of the meter the example below uses our recommended 0C and 100C (32 and 212F) as these temperatures can be achieved using water at the point of freezing and boiling respectively. 1) Place the thermocouple at the first known temperature (e.g. 0C (32F)). Adjust the OFFSET potentiometer to display the correct value (e.g. 000 for C (or 032 for F)). 2) Place the thermocouple at the second known temperature (e.g. 100C (212F)) and adjust the CAL potentiometer to display the correct value (e.g. 100 for C (or 212 for F)). 3) Repeat steps 1 and 2 until there are no more adjustments of CAL and OFFSET required to display the correct reading at each known temperature. SCREW TERMINAL FUNCTIONS 1. LP- Negative power supply to the LED backlighting 2. LP+ Positive power supply to the LED backlighting 3. T- Connection to negative part of thermocouple 4. T+ Connection to positive part of thermocouple 5. V- Negative power supply connection to the meter Check position of DIP switch 2 before connection power supply 6. V+ Positive power supply connection to the meter 7. SW- Negative switch connection Used to cycle between current, maximum and minimum readings since power-on 8. SW+ Positive switch connection Note - When connecting thermocouples, ensure that the wires are carefully cleaned and are connected directly to the module. Only use extension cables and connectors specifically designed for thermocouples. DIMENSIONS All dimensions in mm (inches) Panel cut-out 72 x 40 (2.83 x 1.57) Panel cut-out 72 x 40 (2.83 x 1.57) Maximum panel thickness 3mm (0.12). Maximum panel thickness 3mm (0.12). 76.0 (2.99) 76.0 (2.99) a a 72.5 (2.85) 72.5 (2.85) a. 1.0 (0.04) a. 1.0 (0.04) b. 2.0 (0.08) b. 2.0 (0.08) c. 6.5 c.(0.26)6.5 (0.26) d. 11.5 d.(0.45)11.5 (0.45) e. 11.0 e.(0.43)11.0* (0.43)* *typical depth of tallest component behind PCB*typical depth of tallest component behind PCB, , this dim ethnissi odnim ise fnosri ognu iidsa fnocr eg uoindlay.nce only. 51.0 (2.01) 51.0 (2.01) b c b c 61.5 (2.42)61.5 (2.42) d e d e 51.0 (2.01)51.0 (2.01) 5.7 5.7 (0.22) (0.22) CAL OFFSET CAL OFFSET 1 18 8 REAR REAR VIEW VIEW 3.0 3.0 71.5 (2.81) (0.12) (0.12) 71.5 (2.81) www.lascarelectronics.com Specifications liable to change without prior warning Issue 2 06/2010 S.L Applies to DTM 995B Page 2 of 3 39.0 (1.54) 44.0 (1.73) 24.0 (0.94) 40.5 (1.59) 39.0 (1.54) 44.0 (1.73) 24.0 (0.94) 40.5 (1.59) 24.0 (0.94) 24.5 (0.96) 24.0 (0.94) 24.5 (0.96) LP- LP+ T- LTP+- LP+ V- T- V+ T+ SW- V- SW+ V+ SW- SW+

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free
Lascar
Lascar Electronics

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted