Product Information

HARS-X-7-0.01

HARS-X-7-0.01 electronic component of IET LABS

Datasheet
Decade Boxes HIGH ACCURACY DECADE RESIST SUBSTITUTER

Manufacturer: IET LABS
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 4837.5239 ea
Line Total: USD 4837.5239

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Thu. 11 Apr to Mon. 15 Apr

MOQ : 1
Multiples : 1

Stock Image

HARS-X-7-0.01
IET LABS

1 : USD 4644.0231

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Resistance Range
Accuracy
Height
Length
Series
Type
Voltage
Width
Brand
Product Type
Subcategory
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
RS-200 electronic component of IET LABS RS-200

Decade Boxes Resistance Decade Box 1 O - 10 MO 1%
Stock : 108

RS-200-SC electronic component of IET LABS RS-200-SC

Decade Boxes Resistance DecadeBox with Shielded Case
Stock : 0

0510-9708-01(H) electronic component of IET LABS 0510-9708-01(H)

Decade Boxes 1M ohm Decade Switch Assembly
Stock : 1

Image Description
RDB-10 electronic component of Global Specialties RDB-10

Decade Boxes HANDHELD RESISTANCE DECADE BOX
Stock : 16

CDB-10 electronic component of Global Specialties CDB-10

Decade Boxes HANDHELD CAPACITANCE DECADE BOX
Stock : 3

380400 electronic component of Teledyne FLIR / Extech 380400

Decade Boxes Resistance Decade
Stock : 11

380405 electronic component of Teledyne FLIR / Extech 380405

Decade Boxes Capacitance Decade
Stock : 9

RS-200 electronic component of IET LABS RS-200

Decade Boxes Resistance Decade Box 1 O - 10 MO 1%
Stock : 108

BR07 electronic component of AEMC BR07

RESISTANCE DECADE BOX, 1 OHM-11.11111MOHM
Stock : 5

DR08 electronic component of ELC DR08

DECADE BOX, RESISTOR 0.1OHM
Stock : 0

RS-200-SC electronic component of IET LABS RS-200-SC

Decade Boxes Resistance DecadeBox with Shielded Case
Stock : 0

0510-9708-01(H) electronic component of IET LABS 0510-9708-01(H)

Decade Boxes 1M ohm Decade Switch Assembly
Stock : 1

High Accuracy Decade Resistance Substituter HARS-X Series Page 1 of 2 Tight-tolerance, laboratory-grade decade sub s t ut ers, for applica ons requiring a cost-e ec ve, high-per form ance resis- tance decade box. Features: 6 Decade HARS-X High Accuracy Resistance Sub sti tut er Resistance from 1 m to 111 M Available in double-power version: HARS-X2 Wide choice: single through 11 decade units See also: High-accuracy: 0.01% (100 ppm) Higher accuracy: HARS-LX Series Very low zero-resistance: <1 m per decade Higher power: HPRS Series High-performance solid silver-alloy switches Higher resistance: HRRS Series Low temperature coe cient: 5 ppm/C Higher voltage: HRRS-5kV and HRRS-10kV Series Non-induc ve or low-inductance resistors RTD simulators: RTD Series -- without zero subtrac on Rack moun ng available Programmable models: PRS Series Special and custom con gura ons available SPECIFICATIONS HARS-X HARS-X2 Total Long-term T emperature Resistance Stability Max Max decade stability coef cient Resistor type Max Max power Max Max power voltage voltage per step (ppm/yr) resistance (ppm/3 yrs) (ppm/C) current (per step) current (per step) (per step) (per step) 10 m W 50 75 50 8.0 A 5 mV 0.04 W 9.0 A 9 mV 0.08 W 1 m W 10 mW 100 m W 50 75 20 Resistance wire 4.0 A 40 mV 0.16 W 6.3 A 63 mV 0.4 W 100 m W 1 W 50 75 20 1.6 A 0.16 V 0.25 W 2.2 A 0.3 V 0.5 W 1 W 10 W 20 25 20 0.8 A 0.8 V 0.6 W 1.1 A 1.1 V 1.2 W 10 W 100 W 20 25 15 0.25 A 2.5 V 0.6 W 0.35 A 3.5 V 1.2 W 1 kW 20 25 5 80 mA 8 V 0.6 W 110 mA 11 V 1.2 W 100 W Wirewound, non- 10 kW 20 25 5 23 mA 23 V 0.5 W 35 mA 35 V 1.2 W 1 kW inductive 10 k W 100 k W 20 25 5 7 mA 70 V 0.5 W 11 mA 110 V 1.2 W 100 kW 1 MW 20 25 5 2.3 mA* 230 V* 0.5 W* 3 mA* 500 V* 1 W* 1 MW 10 M W 20 25 5 0.7 mA* 700 V* 0.5 W* 1 mA* 1000 V* 1 W* 100 MW 50 100 10 Metal oxide lm 0.1 mA* 1000 V* 0.1 W* 0.1 mA* 1000 V* 0.1 W* 10 M W *Subject to maximum of 2000 V to case Switch capacitance: Mechanical: Accuracy: <1 pF between contacts 1 M decades: (0.01% + 2 m) Model Dimensions W eight 1 0 M decades: 0.03% Terminals: after subtraction of zero resistance, at 23C 3 terminals, High, Low, and (9.5 cm W x 8.3 cm H x 11.0 cm D) traceable to SI GND via gold-plated, 5-way, 1 decade 0.45 kg 1 lb 3.75 x 3.25 x 4.33 tellurium-copper binding Zero resistance: (31 cm W x 8.9 cm H x 10.2 cm D) posts with low thermal emf 1 M decades: <1 m per decade at dc 1.7 kg 3.8 lb 2-3 decade 12.2 x 3.5 x 4 and low resistance. 10 M decade: 3 m at dc (37.6 cm W x 8.9 cm H x 10.2 cm D) Max voltage to case: 4-5 decade 2.0 kg 4.3 lb -K option with 5 terminals 14.8 x 3.5 x 4 2000 V peak for Kelvin connection is (43.9 cm W x 8.9 cm H x 10.2 cm D) 2.4 kg 5.3 lb 6-7 decades En vironmental conditions: available as an option to 17.3 x 3.5 x 4 reduce zero resistance. O perating: 10C to 40C <80% RH 3.5 kg 7.7 lb 8-9 decades (48.3 cm W x 17.8 cm H x 17.8 cm D) Storage: -40C to 70C -K option is not available for 19 x 7 x 7 3.7 kg 8.1 lb 10-11 decades Sw itches: 1 decade housing. Continuous rotation -RO Rear outputs are 1 1 positions marked0 10 Multiple solid silver-alloy contacts available as an option. IET LABS, INC. in the GenRad Tradition www.ietlabs.com TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 HARS-X Catalog Pages/Feb. 2021 NewHigh Accuracy Decade Resistance Substituter HARS-X Series Page 2 of 2 SINGLE DECADE UNITS Single-decade units are avail able with resis- It may be panel-mounted and combined with tance from as low as 1 m per step to as high additional units to form po ten ti om e ter cir cuits as 10 M per step. These units satisfy many or other con gu ra t ions. system applications req uiri ng only a sin gle de- Each unit consists of low-ind uc tance re sist ors cade while main tain ing all the quality features in series, with a high per for mance solid silver of the HARS se ries. al loy contact switch. Each decade is enclosed in an alu mi num case which can serve as a shield. Single-De cade HARS-X Unit ORDERING INFORMATION Number of Number of Model * Total resistance Resolution Model * Total resistance Resolution decades decades HARS-X-1-0.001 0.01 W 1 0.001 W HARS-X-5-0.001 111.11 W 5 0.001 W 1.1111 kW 5 0.01 W HARS-X-1-0.01 0.1 W 1 0.01 W HARS-X-5-0.01 HARS-X-1-0.1 1 W 1 0.1 W HARS-X-5-0.1 11.111 kW 5 0.1 W 111.11 kW 5 1 W HARS-X-1-1 10 W 1 1 W HARS-X-5-1 HARS-X-1-10 100 W 1 10 W HARS-X-5-10 1.1111 M W 5 10 W 11.111 MW 5 100 W HARS-X-1-100 1 kW 1 100 W HARS-X-5-100 HARS-X-1-1k 10 k W 1 1 kW HARS-X-5-1k 111.11 MW 5 1 kW 1.111 11 kW 6 0.001 W HARS-X-6-0.001 HARS-X-1-10k 100 kW 1 10 kW HARS-X-6-0.01 11.1111 kW 6 0.01 W 1 M W 1 100 kW HARS-X-1-100k 111.111 kW 6 0.1 W HARS-X-6-0.1 HARS-X-1-1M 10 M W 1 1 MW HARS-X-6-1 1.111 11 MW 6 1 W 100 M W 1 10 MW HARS-X-1-10M 11.1111 MW 6 10 W HARS-X-6-10 HARS-X-2-0.001 0.11 W 2 0.001 W HARS-X-6-100 111.111 MW 6 100 W 1.1 W 2 0.01 W HARS-X-2-0.01 11.111 11 kW 7 0.001 W HARS-X-7-0.001 HARS-X-2-0.1 11 W 2 0.1 W HARS-X-7-0.01 111.1111 k W 7 0.01 W 110 W 2 1 W HARS-X-2-1 1.111 111 MW 7 0.1 W HARS-X-7-0.1 HARS-X-2-10 1.1 kW 2 10 W HARS-X-7-1 11.111 11 MW 7 1 W 11 kW 2 100 W HARS-X-2-100 111.1111 MW 7 10 W HARS-X-7-10 HARS-X-2-1k 110 k W 2 1 k W HARS-X-8-0.001 111.111 11 kW 8 0.001 W 1.1 MW 2 10 kW HARS-X-2-10k 1.111 111 1 MW 8 0.01 W HARS-X-8-0.01 HARS-X-2-100k 11 M W 2 100 kW HARS-X-8-0.1 11.111 111 MW 8 0.1 W 110 MW 2 1 MW HARS-X-2-1M 111.111 11 MW 8 1 W HARS-X-8-1 HARS-X-3-0.001 1.11 W 3 0.001 W HARS-X-9-0.001 1.111 111 11 MW 9 0.001 W 11.1 W 3 0.01 W HARS-X-3-0.01 11.111 111 1 MW 9 0.01 W HARS-X-9-0.01 HARS-X-3-0.1 111 W 3 0.1 W HARS-X-9-0.1 111.111 111 MW 9 0.1 W 1.11 kW 3 1 W HARS-X-3-1 11.111 111 11 MW 10 0.001 W HARS-X-10-0.001 HARS-X-3-10 11.1 kW 3 10 W HARS-X-10-0.01 111.111 111 1 MW 10 0.01 W 111 kW 3 100 W HARS-X-3-100 111.111 111 11 MW 11 0.001 W HARS-X-3-1k 1.11 MW 3 1 k W HARS-X-11-0.001 11.1 MW 3 10 kW HARS-X-3-10k * UseX2 for higher power model HARS-X-3-100k 111 MW 3 100 kW 11.11 W 4 0.001 W HARS-X-4-0.001 Options: HARS-X-4-0.01 111.1 W 4 0.01 W -RM: Rack mountable front panel for standard 19 rack 1.111 kW 4 0.1 W -K: Kelvin-type 4-terminal binding posts + GND HARS-X-4-0.1 (for reduced zero resistance) HARS-X-4-1 11.11 k W 4 1 W not available for 1 decade housing 111.1 k W 4 10 W HARS-X-4-10 -RO: Rear output HARS-X-4-100 1.111 MW 4 100 W 11.11 MW 4 1 kW HARS-X-4-1k HARS-X-4-10k 111.1 M W 4 10 kW IET LABS, INC. in the GenRad Tradition www.ietlabs.com TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 HARS-X Catalog Pages/Feb. 2021

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted