Product Information

858-004-01F

Product Image X-ON

Datasheet
Glenair Modular Connectors Ethernet Connectors Socket w OptGrommet Follower
Manufacturer: Glenair



Price (Ex GST)

From 1589.8579

1 - Global Stock
Ships to you between
Wed. 19 May to Fri. 21 May

MOQ: 1 Multiples:1
Pack Size :   1
Availability Price Quantity
1 - Global Stock


Ships to you between Wed. 19 May to Fri. 21 May

MOQ : 1
Multiples : 1

Stock Image

858-004-01F
Glenair

1 : $ 1633.4211
5 : $ 1622.3053
10 : $ 1611.3474
25 : $ 1589.8579

Buy
   
Manufacturer
Glenair
Product Category
Modular Connectors / Ethernet Connectors
Product
Hybrid Ethernet Connectors
Performance Category
Cat 6A
Number of Positions
8 Position
Shielding
Shielded
Number of Ports
1
Mounting Style
Cable
Termination Style
Crimp
Contact Plating
Silver
Gender
Female
Operating Temperature Range
- 55 C to +175 C
Brand
Glenair
Tradename
El-Ochito
Cnhts
8538900000
Hts Code
8538908180
Maximum Operating Temperature
+175 C
Minimum Operating Temperature
- 55 C
Product Type
Modular Connectors / Ethernet Connectors
Subcategory
Modular Connectors / Ethernet Connectors
Taric
8538909999
LoadingGif
Image
Mfr. Part No.
Description
Stock
Circular MIL Spec Connector
2
Circular MIL Spec Connector
1
Circular MIL Spec Connector
4
Image
Mfr. Part No.
Description
Stock
RJ12 6 POSITION 4 CONDUCTOR MODULAR JACK PLUG MALE
1904
Modular Connectors / Ethernet Connectors 8P F SUB MODULAR R/A BRD MNT THROUGH HOLE
3
Hirose Connector Modular Connectors Ethernet Connectors COVER MOD 8 8 BLUE 1=50
805
Hirose Connector Modular Connectors Ethernet Connectors 8P M MODULAR PLUG IDC EMI PROTECT TH
141
Hirose Connector Modular Connectors Ethernet Connectors RJ45 PLUG 8POS CAT6
53

SERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type How To Order 233-217 Sample Part Number 233-217 ?G6 NF 25 ? 08 A N Series / Basic Part No. SuperNine? Environmental High-Speed connector G6 = Plug, with EMI spring 05 = Receptacle, in-line Connector Style* 07 = Receptacle, jam nut 00 = Receptacle, wall mount with slotted holes NF = Cadmium Olive Drab MT = Nickel PTFE Material/Finish ME = Electroless Nickel ZR = Black Zinc Nickel Shell Size 9 , 11, 17, 19, 21, 23, 25 Ground Option G = Common Ground ? = None C Insert Arrangement Per MIL-STD-1560; See Page C-7 Insert Designator A = Pin insert, less contacts B = Socket insert, less contacts See Table Alternate Polarization* A, B, C, D, E, N = Normal (IAW MIL-DTL-38999 Series III) *Refer to Section A for complete details Contact Type Glenair P/N Cable* ? SEALING BOOT Coax Pin: 852-007-08-367 Sealing boot provides wire seal. Slide M17/095-RG180 95 (per M39029/59 & /60) Socket: 852-006-08-366 boot onto wire before terminating contact. After contact is installed in connector, slide boot forward into Pin: 853-014-01 connector grommet to seal the contact Differential Twinax Socket: 853-013-01 Gore RCN8945 100 See note 9 cavity. "F" suffix added on contact part number specifies contact supplied with Pin: 858-003-01 sealing boot. 963-003-26 El Ochito Socket: 858-004-01 100 (PIC E6A3826) See note 9 Wire Diameter Part Number Pin: 854-001-01 In mm Tensolite Quadrax Socket: 854-002-01 100 .090 -.130 2.3 - 3.3 859-042-01 NF26Q100 See note 9 .130 - .170 3.3 -4.3 859-0042-02 .170 - .205 4.3 - 5.2 859-042-03 8 Triax/Concentric Pin: 853-003-08-625 .190 - .220 4.8 - 5.6 687-643-8-02 M17/176-0002 78 Twinax Socket: 853-004-08-628 .985 (25.02) MAX * Consult factory for other cable options .350 .326 (8.89) (8.28) NOTES 1. Insert arrangements IAW MIL-STD-1560. 4. See reference information in this section 7. All contacts, insertion/removal tool, and Contact Glenair for additional for recommended mounting holes for sealing plugs to be ordered separately. arrangement options. wall mount and jam nut receptacles. 8. Used for El Ochito contacts only. 2. All contacts, insertion/removal tool, and 5. Consult factory for additional 9. For contacts with boot, add F suffix. sealing plugs to be ordered separately. information. 3. Dimensions in in. (mm) are subject to 6. Blue color band indicates rear release change without notice. retention system. C-10 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? CatalogSERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type How To Order 233-217 Sample Part Number 233-217 ?G6 NF 25 ? 08 A N Series / Basic Part No. SuperNine? Environmental High-Speed connector G6 = Plug, with EMI spring 05 = Receptacle, in-line Connector Style* 07 = Receptacle, jam nut 00 = Receptacle, wall mount with slotted holes NF = Cadmium Olive Drab MT = Nickel PTFE Material/Finish ME = Electroless Nickel ZR = Black Zinc Nickel Shell Size 9 , 11, 17, 19, 21, 23, 25 Ground Option G = Common Ground ? = None C Insert Arrangement Per MIL-STD-1560; See Page C-7 Insert Designator A = Pin insert, less contacts B = Socket insert, less contacts See Table Alternate Polarization* A, B, C, D, E, N = Normal (IAW MIL-DTL-38999 Series III) *Refer to Section A for complete details Contact Type Glenair P/N Cable* O SEALING BOOT Coax Pin: 852-007-08-367 Sealing boot provides wire seal. Slide M17/095-RG180 95 (per M39029/59 & /60) Socket: 852-006-08-366 boot onto wire before terminating contact. After contact is installed in connector, slide boot forward into Pin: 853-014-01 connector grommet to seal the contact Differential Twinax Socket: 853-013-01 Gore RCN8945 100 See note 9 cavity. "F" suffix added on contact part number specifies contact supplied with Pin: 858-003-01 sealing boot. 963-003-26 El Ochito Socket: 858-004-01 100 (PIC E6A3826) See note 9 Wire Diameter Part Number Pin: 854-001-01 In mm Tensolite Quadrax Socket: 854-002-01 100 .090 -.130 2.3 - 3.3 859-042-01 NF26Q100 See note 9 .130 - .170 3.3 -4.3 859-0042-02 .170 - .205 4.3 - 5.2 859-042-03 8 Triax/Concentric Pin: 853-003-08-625 .190 - .220 4.8 - 5.6 687-643-8-02 M17/176-0002 78 Twinax Socket: 853-004-08-628 .985 (25.02) MAX * Consult factory for other cable options .350 .326 (8.89) (8.28) NOTES 1. Insert arrangements IAW MIL-STD-1560. 4. See reference information in this section 7. All contacts, insertion/removal tool, and Contact Glenair for additional for recommended mounting holes for sealing plugs to be ordered separately. arrangement options. wall mount and jam nut receptacles. 8. Used for El Ochito contacts only. 2. All contacts, insertion/removal tool, and 5. Consult factory for additional 9. For contacts with boot, add F suffix. sealing plugs to be ordered separately. information. 3. Dimensions in in. (mm) are subject to 6. Blue color band indicates rear release change without notice. retention system. C-10 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? CatalogSERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type G6 - PLUG 1.220 MAX MASTER KEY A G B H F C E D C 07 - JAM NUT RECEPTACLE 1.280 (32.51) Max .890 (22.61) Max .579 (14.71) Master .555 (14.10) Keyway A G B H F C E D .510 (12.95) Max Fully Mated Indicator Band See Note 4 Color Red O-ring Jam Nut Per D38999/28 05 - IN-LINE RECEPTACLE 00 - WALL MOUNT RECEPTACLE (with slotted holes) 1.240 1.240 (31.49) (31.49) Max Max MASTER See Note 7 KEYWAY Master See Note 6 Keyway A G B H F C E D .510 () Max .510 () Max Fully Mated Indicator Fully Mated Indicator Band Color: Red See Note 4 Band Color: Red C-11 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? CatalogSERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type How To Order 233-217 Sample Part Number 233-217 ?G6 NF 25 ? 08 A N Series / Basic Part No. SuperNine? Environmental High-Speed connector G6 = Plug, with EMI spring 05 = Receptacle, in-line Connector Style* 07 = Receptacle, jam nut 00 = Receptacle, wall mount with slotted holes NF = Cadmium Olive Drab MT = Nickel PTFE Material/Finish ME = Electroless Nickel ZR = Black Zinc Nickel Shell Size 9 , 11, 17, 19, 21, 23, 25 Ground Option G = Common Ground ? = None C Insert Arrangement Per MIL-STD-1560; See Page C-7 Insert Designator A = Pin insert, less contacts B = Socket insert, less contacts See Table Alternate Polarization* A, B, C, D, E, N = Normal (IAW MIL-DTL-38999 Series III) *Refer to Section A for complete details Contact Type Glenair P/N Cable* O SEALING BOOT Coax Pin: 852-007-08-367 Sealing boot provides wire seal. Slide M17/095-RG180 95 (per M39029/59 & /60) Socket: 852-006-08-366 boot onto wire before terminating contact. After contact is installed in connector, slide boot forward into Pin: 853-014-01 connector grommet to seal the contact Differential Twinax Socket: 853-013-01 Gore RCN8945 100 See note 9 cavity. "F" suffix added on contact part number specifies contact supplied with Pin: 858-003-01 sealing boot. 963-003-26 El Ochito Socket: 858-004-01 100 (PIC E6A3826) See note 9 Wire Diameter Part Number Pin: 854-001-01 In mm Tensolite Quadrax Socket: 854-002-01 100 .090 -.130 2.3 - 3.3 859-042-01 NF26Q100 See note 9 .130 - .170 3.3 -4.3 859-0042-02 .170 - .205 4.3 - 5.2 859-042-03 8 Triax/Concentric Pin: 853-003-08-625 .190 - .220 4.8 - 5.6 687-643-8-02 M17/176-0002 78 Twinax Socket: 853-004-08-628 .985 (25.02) MAX * Consult factory for other cable options .350 .326 (8.89) (8.28) NOTES 1. Insert arrangements IAW MIL-STD-1560. 4. See reference information in this section 7. All contacts, insertion/removal tool, and Contact Glenair for additional for recommended mounting holes for sealing plugs to be ordered separately. arrangement options. wall mount and jam nut receptacles. 8. Used for El Ochito contacts only. 2. All contacts, insertion/removal tool, and 5. Consult factory for additional 9. For contacts with boot, add F suffix. sealing plugs to be ordered separately. information. 3. Dimensions in in. (mm) are subject to 6. Blue color band indicates rear release change without notice. retention system. C-10 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? CatalogSERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type How To Order 233-217 Sample Part Number 233-217 ?G6 NF 25 ? 08 A N Series / Basic Part No. SuperNine? Environmental High-Speed connector G6 = Plug, with EMI spring 05 = Receptacle, in-line Connector Style* 07 = Receptacle, jam nut 00 = Receptacle, wall mount with slotted holes NF = Cadmium Olive Drab MT = Nickel PTFE Material/Finish ME = Electroless Nickel ZR = Black Zinc Nickel Shell Size 9 , 11, 17, 19, 21, 23, 25 Ground Option G = Common Ground ? = None C Insert Arrangement Per MIL-STD-1560; See Page C-7 Insert Designator A = Pin insert, less contacts B = Socket insert, less contacts See Table Alternate Polarization* A, B, C, D, E, N = Normal (IAW MIL-DTL-38999 Series III) *Refer to Section A for complete details Contact Type Glenair P/N Cable* O SEALING BOOT Coax Pin: 852-007-08-367 Sealing boot provides wire seal. Slide M17/095-RG180 95 (per M39029/59 & /60) Socket: 852-006-08-366 boot onto wire before terminating contact. After contact is installed in connector, slide boot forward into Pin: 853-014-01 connector grommet to seal the contact Differential Twinax Socket: 853-013-01 Gore RCN8945 100 See note 9 cavity. "F" suffix added on contact part number specifies contact supplied with Pin: 858-003-01 sealing boot. 963-003-26 El Ochito Socket: 858-004-01 100 (PIC E6A3826) See note 9 Wire Diameter Part Number Pin: 854-001-01 In mm Tensolite Quadrax Socket: 854-002-01 100 .090 -.130 2.3 - 3.3 859-042-01 NF26Q100 See note 9 .130 - .170 3.3 -4.3 859-0042-02 .170 - .205 4.3 - 5.2 859-042-03 8 Triax/Concentric Pin: 853-003-08-625 .190 - .220 4.8 - 5.6 687-643-8-02 M17/176-0002 78 Twinax Socket: 853-004-08-628 .985 (25.02) MAX * Consult factory for other cable options .350 .326 (8.89) (8.28) NOTES 1. Insert arrangements IAW MIL-STD-1560. 4. See reference information in this section 7. All contacts, insertion/removal tool, and Contact Glenair for additional for recommended mounting holes for sealing plugs to be ordered separately. arrangement options. wall mount and jam nut receptacles. 8. Used for El Ochito contacts only. 2. All contacts, insertion/removal tool, and 5. Consult factory for additional 9. For contacts with boot, add F suffix. sealing plugs to be ordered separately. information. 3. Dimensions in in. (mm) are subject to 6. Blue color band indicates rear release change without notice. retention system. C-10 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? CatalogSERIES 23 High speed connectors 233-217 Plug and receptacle with keyed size#8 inserts MIL-DTL-38999 Series III type G6 - PLUG 1.220 MAX MASTER KEY A G B H F C E D C 07 - JAM NUT RECEPTACLE 1.280 (32.51) Max .890 (22.61) Max .579 (14.71) Master .555 (14.10) Keyway A G B H F C E D .510 (12.95) Max Fully Mated Indicator Band See Note 4 Color Red O-ring Jam Nut Per D38999/28 05 - IN-LINE RECEPTACLE 00 - WALL MOUNT RECEPTACLE (with slotted holes) 1.240 1.240 (31.49) (31.49) Max Max MASTER See Note 7 KEYWAY Master See Note 6 Keyway A G B H F C E D .510 () Max .510 () Max Fully Mated Indicator Fully Mated Indicator Band Color: Red See Note 4 Band Color: Red C-11 ? 2014 Glenair, Inc ? 1211 Air Way, Glendale, CA 91201 ? 818-247-6000 ? www.glenair.com ? U.S. CAGE code 06324 ? Series 23 SuperNine? Catalog

Tariff Concession Code
Tariff Desc

1225594
8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8536.69.90 PLUG AND SOCKET COMBINATIONS, being ANY of the following:
(a) 2, 3, 4, 6, 9, 12 OR 15 way, rated to 300 V, maximum current of 15 amps;
(b) 2, 3 OR 12 way, single in line pin header;
(c) 1.3mm plug to 2.1mm socket;
(d) 2.5mm plug to 3.5mm socket
TC 9900931

8536.69.90 SOCKETS, being ANY of the following:
(a) single pin, NOT exceeding 3.5 mm;
(b) micro, single pin, 2 mm;
(c) DC power connector, 2.1 mm OR 2.5 mm;
(d) 9 pin OR 15 pin, sub D;
(e) 2, 4 OR 8 pole microphone connector;
(f) 2, 3, 5, 6, 7, 8 OR 13 pin DIN;
(g) 16, 20, 26, 34, 40 OR 50 way dual in line crimp-on
TC 9900883

8536.69 JACKS, phono, RCA Type
TC 8438480

8536.69.90 CONNECTORS, electrical, incorporating twist locking mechanism
TC 9703905

8536.70.90 CONNECTORS, OPTICAL Op. 12.06.2007 FIBRE
TC 0708845

8536.69 PLUGS, modular, telephone, to suit RJ 11 sockets and complying with US Standard FCC 68
TC 9203687

8536.90.90 LUGS, being solderable, copper connectors
TC 0613954

8535.90.00 CRIMPING TERMINALS, having bell-mouth OR flared cable entry
TC 9504891

8536.90 HOLDERS, dry cell
TC 8438464

8536.69.90 TC 1440896 POWER POINTS, plastic AND/OR metal, single OR multiple power outlet, with OR without EITHER of the following:
(a) LED (light-emitting diode) night light;
(b) single OR multiple power switches

8536.69 PLUGS/SOCKETS, adaptor being EITHER of the following:
(a) providing for plug or socket configurations used in other countries to connect to Australian standard plugs or sockets;
(b) providing for plug or socket configurations of Australian standard type to connect to plugs or sockets used in other countries
TC 8807068