Product Information

TPN08

TPN08 electronic component of Europa

Datasheet
DISTRIBUTION BOARD, 3-PH, 125A, 24WAY

Manufacturer: Europa
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 1021.2813 ea
Line Total: USD 1021.2813

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1

Stock Image

TPN08
Europa

1 : USD 577.7782

     
Manufacturer
Product Category
Consumer Unit Usage
Enclosure Material
Supply Voltage
Current Rating
No Of Branch Circuits
External Height
External Width
External Depth
Product Range
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
EUC1P10C electronic component of Europa EUC1P10C

CIRCUIT BREAKER, 1 POLE, 10A, 230VAC
Stock : 0

EUC2P10C electronic component of Europa EUC2P10C

CIRCUIT BREAKER, 2 POLE, 10A, 230VAC
Stock : 0

EUC2P16C electronic component of Europa EUC2P16C

CIRCUIT BREAKER, 2 POLE, 16A, 230VAC
Stock : 0

EUC2P6C electronic component of Europa EUC2P6C

CIRCUIT BREAKER, 2 POLE, 6A, 230VAC
Stock : 0

EUC1P1C electronic component of Europa EUC1P1C

CIRCUIT BREAKER, 1 POLE, 1A, 230VAC
Stock : 0

EUC1P20C electronic component of Europa EUC1P20C

CIRCUIT BREAKER, 1 POLE, 20A, 230VAC
Stock : 32

EUC2P4C electronic component of Europa EUC2P4C

CIRCUIT BREAKER, 2 POLE, 4A, 230VAC
Stock : 0

PBE2821013 electronic component of Europa PBE2821013

ENCLOSURE, WALL MOUNT, ABS, GREY
Stock : 0

PBE403019 electronic component of Europa PBE403019

ENCLOSURE, WALL MOUNT, ABS, GREY
Stock : 0

PBE504017 electronic component of Europa PBE504017

ENCLOSURE, WALL MOUNT, ABS, GREY
Stock : 15

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

3 Phase Board Instructions October 2013:Layout 2 24/10/13 12:24 Page 1 TPN 3 Phase 125A Distribution Board Important Information This unit must be installed by a qualified competent person in compliance with current requirements for Electrical Installations (IEE Wiring regulations Seventeenth Edition: BS7671). Ensure that all power supplying this equipment is switched OFF before working on or inside the unit. Confirm the power is off with an appropriately rated volt-sensing device. Make sure all devices, covers and doors are replaced and secured before switching the power supply back on to the unit. Remove the gland plates prior to slotting or cutting for cable entries to avoid ingress of swarf & other debris. The user guide must be available for future reference after installation and testing. The total current supplied into the unit must not exceed the rating of the incoming main switch or RCCBs or any additional limitation. The total sum of the individual MCBs ratings may exceed this value when there is appropriate diversity in the installation. This unit is only suitable for indoor use. This unit and internal components have been tested to the following standards: Distribution Board: ....EN60439-3 MCBs: ........EN60898 RCCBs: .................... EN61008-1 RCBO: ....... EN61009-1 Main Switch: ......EN60947-3 Adjacent thermal-magnetic MCBs should not be continuously used at their nominal rated currents when mounted in an enclosure. A derating factor of 60% is advised for the MCBs nominal rated current when a continued load is applied. Before fitting the front cover ensure that all connections (including factory connections) are tight - DO NOT USE POWER TOOLS TO TIGHTEN CONNECTIONS Testing the Installation: Once the installation has been completed it is essential to test the unit in accordance with the latest edition of the BS7671 IEE 17th Edition Wiring regulations. Failure to follow these instructions could result in serious injury or death TPN 3 Phase Board Dimensions A B C D E F G H 12 455 492 392 465 507 320 130 15 18 455 546 446 465 561 320 130 15 24 455 600 500 465 615 320 130 15 30 455 654 554 465 669 320 130 15 36 455 708 608 465 723 320 130 15 42 455 762 662 465 777 320 130 15 48 455 816 716 465 831 320 130 15 54 455 870 770 465 885 320 130 15 For More Information sales europacomponents.com3 Phase Board Instructions October 2013:Layout 2 24/10/13 12:24 Page 2 Quality Components at Competitive Prices Pre-fitted with 125A 4 Pole Isolator Provision for Direct Connected Neutral Input using Pozidrive PZ2 the Cage Terminal Directly Connected to the Neutral Bar Two Top Clips Hold Lid in Position Front Panel Pozidrive PZ2 x 4 Lockable Door Handle with Key Front Panel Easy Release Mechanism Blank Panels for Easy Identification Lockable Door Handle with Key Now with Busbar Terminal Extensions & Cover Plate Pozidrive PZ2 Use packaging to cover inside of unit to reduce swarf when removing gland plates Remove Gland Plates before cutting cable entries Installation of MCBs Ensure power supply is switched off. Ensure MCB is switched off. Fully loosen all MCB terminal screws. Push MCB onto appropriate busbar outgoing way with busbar connection going into top cage as indicated on busbar way label, making sure the din clip is closed and faces towards the busbar assembly. Fully tighten busbar connections to 1.7Nm (15lbf-in). Fit busbar insulators (ECUBPD) to all unused outgoing ways. DO NOT USE POWER TOOL SCREWDRIVERS ON ELECTRICAL CONNECTIONS Installation of RCBOs (single pole) Easy removal of Gear Tray Ensure power supply is switched off. Fully loosen all RCBO busbar terminal screws. Push RCBO onto appropriate busbar outgoing way, as indicated on busbar way label, making sure the DIN clip is closed and faces towards the busbar assembly. Fully tighten the busbar connection to 1.7Nm (15lbf-in). Connect both live and neutral outgoing cable to RCBO outgoing terminals. Connect neutral lead to appropriate numbered terminal on the neutral terminal bar. Connect white functional earth lead to appropriate numbered terminal on earth terminal bar. Fit busbar insulators (ECUBPD) to all unused outgoing ways. DO NOT USE POWER TOOL SCREWDRIVERS ON ELECTRICAL CONNECTIONS Please Note: Before fitting the front cover, check the tightness of all connections, including factory made connections and ensure that blanks are fitted to all unused MCB ways. For More Information sales europacomponents.com

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted