Product Information

W1G200-EF01-01

W1G200-EF01-01 electronic component of ebm papst

Datasheet
EC Fans DC Tubeaxial Fan, 250mm Round, 24VDC, Ball Bearing, 4 Lead Wires

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 177.7654 ea
Line Total: USD 177.7654

66 - Global Stock
Ships to you between
Fri. 05 Apr to Thu. 11 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
66 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1

Stock Image

W1G200-EF01-01
ebm papst

1 : USD 183.4087
5 : USD 165.8475
10 : USD 162.3956
25 : USD 161.5819
50 : USD 160.7812
75 : USD 159.9675
100 : USD 159.1669

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 33

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 27

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 1

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
AC8300H electronic component of ebm papst AC8300H

EC Fans EC Fan, 80x80x32mm, 115VAC, 47.1CFM, 8.3W, 48dBA, 5000RPM, Ball, ACmaxx
Stock : 40

ACI4410HHU electronic component of ebm papst ACI4410HHU

FAN AXIAL 119X38MM
Stock : 0

W3G200-HD23-10 electronic component of ebm papst W3G200-HD23-10

EC Fans EC Axial Fan, 225x225x80mm, 115VAC, 50/60Hz, 623CFM, 65W, 2900RPM, Ball Bearing
Stock : 5

W1G300-BB23-01 electronic component of ebm papst W1G300-BB23-01

EC Fans EC Axial Fan, 300mm Round, 115VAC, 35W, 1300RPM
Stock : 1

S1G200-CA91-02 electronic component of ebm papst S1G200-CA91-02

EC Fans EC Axial Fan, 200mm Round, 230VAC, Ball Bearing
Stock : 2

OA109EC-UR-1TB electronic component of Orion OA109EC-UR-1TB

EC Fans Electronically Commutated (EC) Fan, 120x38mm, Voltage Range 90-265VAC, 115/230 Universal Input, 106CFM, 4.9/5.2W, 43dBA, 3200RPM, Dual Ball Bearing, Terminals
Stock : 25

OA172EC-22-1WB electronic component of Orion OA172EC-22-1WB

EC Fans Electronically Commutated (EC) Fan, 172x150x51mm, 230VAC, 220CFM, 15W, 57dBA, 3000RPM, Dual Ball Bearing, 2 Wire Leads
Stock : 2

OA172EC-11-1TB electronic component of Orion OA172EC-11-1TB

EC Fans Electronically Commutated (EC) Fan, 172x150x51mm, 115VAC, 220CFM, 15W, 57dBA, 3000RPM, Dual Ball Bearing, Terminals
Stock : 0

3238.500 electronic component of Rittal 3238.500

Fan: EC; 200/240VAC; 55m3/h; 49dBA; IP54,IP56; Colour: white
Stock : 2

AC100NR electronic component of ebm papst AC100NR

EC Fans EC Tubeaxial Fan, 130x98.5mm 115VAC, 2.5W, 35dBA, IP44 Rated, ACmaxx Series
Stock : 0

W1G200-EF01-01 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Electromagnetic radiation 2 death or serious injury if the specified actions are not taken. 1.7 Mechanical movement 2 Compliance with the instructions is imperative. 1.8 Emissions 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Transport 2 death or serious injury if the specified actions are not taken. 1.11 Storage 2 Exercise extreme caution while working. 2. INTENDED USE 3 CAUTION Indicates a potentially hazardous situation which can result in 3. TECHNICAL DATA 4 minor or moderate injury or damage to property if the specified 3.1 Product drawing 4 actions are not taken. 3.2 Nominal data 5 3.3 Technical description 5 NOTE 3.4 Mounting data 5 A potentially harmful situation can occur and, if not avoided, can 3.5 Transport and storage conditions 5 lead to property damage. 4. CONNECTION AND STARTUP 6 1.2 Staff qualifications 4.1 Mechanical connection 6 The device may only be transported, unpacked, installed, operated, 4.2 Electrical connection 6 maintained and otherwise used by suitably qualified, trained and 4.3 Routing of cables 6 authorized technical staff. 4.4 Connection diagram 7 Only authorized specialists are permitted to install the device, to carry 4.5 Checking connections 8 out a test run and to perform work on the electrical installation. 4.6 Switching on the device 8 4.7 Switching off the device 8 1.3 Basic safety rules 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 The safety hazards associated with the device must be assessed again CAUSES AND REMEDIES following installation in the final product. 5.1 Cleaning 9 The locally applicable industrial safety regulations are always to be 5.2 Safety inspection 9 observed when working on the device. 5.3 Disposal 9 Keep the workplace clean and tidy. Untidiness in the work area increases the risk of accidents. Note the following when working on the device: Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 5.2 Safety inspection. Replace loose connections and defective cables immediately. WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 51715-5-9970 ENU Change 204653 Approved 2019-06-14 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsW1G200-EF01-01 Operating instructions CAUTION 1.8 Emissions If control voltage or a stored speed set value is applied, WARNING the motor will restart automatically, e.g. after a power Depending on the installation and operating conditions, failure. the sound pressure level may exceed 70 dB(A). Risk of injury Risk of noise-induced hearing loss Keep out of the devices danger zone. Take appropriate technical safety measures. When working on the device, switch off the line voltage Protect operating personnel with appropriate safety and ensure that it cannot be switched back on. equipment such as hearing protection. Wait until the device comes to a stop. Also observe the requirements of local agencies. After working on the device, remove any tools or other objects from the device. 1.9 Hot surface 1.5 Safety and protective features CAUTION High temperature on electronics housing DANGER Risk of burns Protective device missing and protective device not Ensure sufficient protection against accidental contact. functioning Without a protective device there is a risk of serious injury, for 1.10 Transport instance when reaching into the device during operation. Operate the device only with a fixed protective device and NOTE guard grille. Transporting the device The fixed protective device must be able to withstand the Transport the device in its original packaging only. kinetic energy of a fan blade that becomes detached at Secure the device so it cannot slip, e.g. by using a maximum speed. There must not be any gaps which it is lashing strip. possible to reach into with the fingers, for example. 1.11 Storage The device is a built-in component. As the operator, you are responsible for ensuring that the device is secured Store the device, partially or fully assembled, in a dry place, adequately. protected against the weather and free from vibration, in the original Stop the device immediately if you notice a missing or packaging in a clean environment. ineffective protective device. Protect the device against environmental effects and dirt until final installation. 1.6 Electromagnetic radiation We recommend storing the device for no longer than one year in Interference from electromagnetic radiation is possible, e.g. in conjunction order to guarantee trouble-free operation and the longest possible with open- and closed-loop control devices. service life. If impermissible radiation levels occur following installation, appropriate Even devices explicitly intended for outdoor use are to be stored as shielding measures have to be taken by the user. described prior to commissioning. NOTE Maintain the storage temperature, see Electrical or electromagnetic interference after installing Chapter 3.5 Transport and storage conditions. the device in customer equipment. Verify that the entire setup is EMC-compliant. 1.7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. Protect long hair with a cap. Item no. 51715-5-9970 ENU Change 204653 Approved 2019-06-14 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

8414.59.90 FANS INCORPORATING BRUSHLESS MOTORS, having ANY of the following:
(a) DC powered;
Op. 19.10.2000 Dec. 05.01.2001 - TC 0008777
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted