Product Information

PDQ-B-26-650-G-2A2-1-U

PDQ-B-26-650-G-2A2-1-U electronic component of Carling

Datasheet
Circuit Breaker Equipment Leakage 3Pole 50A 480VAC

Manufacturer: Carling
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 474.4031 ea
Line Total: USD 474.4031

9 - Global Stock
Ships to you between
Fri. 05 Apr to Thu. 11 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
9 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1
1 : USD 474.4031
5 : USD 442.7719
10 : USD 401.1131

8 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1
1 : USD 527.7376
2 : USD 517.1829

     
Manufacturer
Product Category
Brand
Notes*
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
6GK5E-73 electronic component of Carling 6GK5E-73

Switch Toggle (ON) None OFF DPST Bat Lever Screw 15A 250VAC 559.27VA Panel Mount with Threads
Stock : 1

1SS-WMSP3-R1/2-M6GE electronic component of Carling 1SS-WMSP3-R1/2-M6GE

Switch Rocker ON OFF ON SPDT PC Pins Small Rocker 3A 250VAC 28VDC Bulk
Stock : 1

2GA721-D-4B-B electronic component of Carling 2GA721-D-4B-B

Switch Toggle ON None OFF SPST Lever Quick Conn 20A 277VAC 1491.4VA Panel Mount with Threads
Stock : 1

3SS-WSP9-M2-RE electronic component of Carling 3SS-WSP9-M2-RE

Switch Push Button OFF (ON) SPST Round Plunger 20VAC 20VDC 0.4VA Momentary Contact PC Pins Thru-Hole
Stock : 1

62111122-0-0-N electronic component of Carling 62111122-0-0-N

Rocker Switches ON-NONE-ON CRV RCKR
Stock : 1

62115919-0-0-N electronic component of Carling 62115919-0-0-N

Rocker Switches DPST ON-NONE-OFF
Stock : 1

2GM721-D-4B-B electronic component of Carling 2GM721-D-4B-B

Toggle Switches DPDT ON-OFF-ON
Stock : 1

2FB54-73/2 HEX electronic component of Carling 2FB54-73/2 HEX

Toggle Switches F-Series Toggle Switch
Stock : 1

2GM720-D-4B-B electronic component of Carling 2GM720-D-4B-B

Toggle Switches G-Series Toggle Switch
Stock : 1

6GG5M-73 electronic component of Carling 6GG5M-73

Toggle Switches
Stock : 0

Image Description
21215-00 electronic component of Eaton 21215-00

Circuit Breakers CIRCUIT BREAKER TYPE II 1
Stock : 275

4404.0009 electronic component of Schurter 4404.0009

Circuit Breakers 7A 0.25" QC Snap-in front
Stock : 215

0812050.ZXST electronic component of Littelfuse 0812050.ZXST

Circuit Breakers 50A
Stock : 1

Hot W51-A121B1-20 electronic component of TE Connectivity W51-A121B1-20

TE Connectivity P&B Circuit Breakers 20A RCKR ACT RED ILL
Stock : 1

1658-A21-00-P10-20A electronic component of ETA 1658-A21-00-P10-20A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

TR11-D-X-63-BB-2-N-10.0A electronic component of Altech TR11-D-X-63-BB-2-N-10.0A

Circuit Breakers TR11sup.prot.,wingD,bl.slid.w/
Stock : 1

1658-G21-00-S83-5A electronic component of ETA 1658-G21-00-S83-5A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

ETIMAT 6 1P D10 electronic component of ETI Polam ETIMAT 6 1P D10

Circuit breaker; 230/400VAC; Inom: 10A; Poles: 1; DIN; Charact: D
Stock : 1

ETIMAT P10 1P B6 electronic component of ETI Polam ETIMAT P10 1P B6

Circuit breaker; 230/400VAC; Inom: 6A; Poles: 1; DIN; Charact: B
Stock : 0

GV4AE11 electronic component of Schneider GV4AE11

Circuit Breakers TeSys BV4/GV4 Aux/Alarm Contact
Stock : 0

PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized overload and short circuit protection. In addition, this breaker senses and guards against faults to ground using a state of the art integrated circuit developed by Carling. This new technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment damage and fire. Features: Overload, short circuit and ground fault protection in a single package Handle style actuators with optional handleguard Wiping Contacts - Mechanical linkage with two-step Agency Certifications: actuation cleans contacts, provides high, positive contact pressure & longer contact life UL Standard 1077 Component Recognition Program as A trip-free mechanism, a safety feature, makes it Equipment Leakage Circuit Interrupter impossible to manually hold the contacts closed during and, Protectors, Supplementary (FTTJ2, File overload or fault conditions. E177510). A common trip linkage between all poles, another safety UL Standard 943 Tested as Ground Fault Circuit Interrupters feature, ensures that an overload in one pole will trip all for Equipment Protection. adjacent poles. CSA Certified Component Equipment Leakage Current Front panel or DIN rail mounting options Interrupter with Supplementary Protector, State of the art integrated circuit developed by Carling under Class C22.2,No. 144-M91, FIle Equipment leakage sensitivity from 10 to 100 milliamps LR47848-50 Integral push-to-test button and LED tripped indicator TUV Certified IEC 947-2 and appendix B: Circuit Breakers Immediate reset after fault has been cleared incorporating Residual Current Protection. Complies with waveform requirements of IEC 1008-1, Type A. Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062-1177 Phone: (860) 793-9281 Fax: (860) 793-9231 Email: sales@carlingtech.com www.carlingtech.com| 2 PD-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and Table B: Lists TUV Certified configurations and performance capabilities performance capabilities as a Component Supplementary Protector. as a Circuit breaker incorporating residual current protection. PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER INTERRUPTING L EAKAGE VOLTAGE CURRENT RATING CAPACITY (AMPS) CURRENT FULL GENERAL UL / CSA MUST - TRIP CIRCUITRMAX ATING L OAD PURPOSE WITHOUTRATING FREQUENCY CONFIGURATION VOLTS HERTZ PHASE AMPS AMPS BACKUP FUSE(MILLIAMPS) 120/208 50/60 1 1-50 --- 5000 7-100 120/208 50/60 31 1-50 --- 5000 7-100 SERIES 208-240 50/60 3 1-50 --- 2000 7-100 480Y 50/60 3 1-30 30.1-50 2000 7-100 Electrical Mechanical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Endurance 10,000 ON-OFF operations @ 6 per Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, minute; with rated current and voltage. 20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 Trip Free All SmartGuard equipment leakeage amps. For other ratings, consult factory. circuit breakers will trip on overload Insulation Resistance Minimum of 100 Megohms @ 500 VDC. or leakage to ground, even when Dielectric Strength 1960 VAC, 60 Hz for one minute actuator is forcibly held in the ON between all electrically isolated position. terminals. Trip Indication The actuator moves to the OFF Resistance, Impedance from Line to Load Terminal position when an overload or earth (Values Based on Series Trip Circuit leakage ground fault causes the Breaker) breaker to trip. The LED is illuminated RESISTANCE, IMPEDANCE VALUES when leakage to ground causes the from Line to Load Terminals Ampere Rating circuit breaker to trip. Physical Number of Poles 2, 3 & 4 20.1 - 50.0 Length (included switched or unswitched neutral) 4.2 inches ( 106.7 mm) Pulse Tolerance Curve Width 2-pole: 3.0 inches (76.2 mm) 60 Hz 1/2 Cycle Inrush Pulse Tolerance I r 3-pole: 3.75 inches (95.3 mm) 4-pole: 4.5 inches (114.3 mm) Time Delay Curves Depth 2.5inches (63.5mm). 22, 24, 26 12x Weight: 2-pole 16.0 oz. (453.6 gm) t 3-pole: 21.4 oz. (606.7 gm) 8.33 16.67 4.165 Time in 4-pole: 26.9 oz. (762.6 gm) Milliseconds Standard Colors Housing - gray; Actuator - black, red, or white Mounting Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or Leakage To Ground 35 x 15mm per DIN EN5002). Standard Must Trip Termination Box Lug Leakage Current Ratings 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory. Environmental Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. Operating Temperature +10C to +50C Test Button On breaker face above actuator. Leakage Trip Indicator Red LED on breaker face above actuator. *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue Plainville, CT 060621177 Phone: (860) 7939281 Fax: (860) 7939231 Email: sales@carlingtech.com www.carlingtech.com Multiple of Rated Current

Tariff Desc

CIRCUIT BREAKERS, AC AND/OR DC, having ALL of the following:
(a) current rating NOT greater than 400 A;
(b) single OR multiple pole;
(c) operating voltage NOT greater than 1 000 V AC
Op. 30.06.11 Dec. date 26.09.11 - TC 1121463
CARLING
Carling Technologies
Carling Technologies Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted