Product Information

ME1-B-94-425-1-A37-B-C

ME1-B-94-425-1-A37-B-C electronic component of Carling

Datasheet
Circuit Breaker Hydraulic Magnetic 1Pole 2.5A 250VAC/80VDC

Manufacturer: Carling
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

3: USD 51.6863 ea
Line Total: USD 155.06

94 - Global Stock
Ships to you between
Thu. 25 Apr to Wed. 01 May
MOQ: 3  Multiples: 1
Pack Size: 1
Availability Price Quantity
94 - Global Stock


Ships to you between Thu. 25 Apr to Wed. 01 May

MOQ : 3
Multiples : 1
3 : USD 51.6863
12 : USD 39.2044
27 : USD 36.5006
51 : USD 34.1119
102 : USD 33.0356
252 : USD 32.1694
501 : USD 31.9331

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
Notes*
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
6GK5E-73 electronic component of Carling 6GK5E-73

Switch Toggle (ON) None OFF DPST Bat Lever Screw 15A 250VAC 559.27VA Panel Mount with Threads
Stock : 28

1SS-WMSP3-R1/2-M6GE electronic component of Carling 1SS-WMSP3-R1/2-M6GE

Switch Rocker ON OFF ON SPDT PC Pins Small Rocker 3A 250VAC 28VDC Bulk
Stock : 1

2GA721-D-4B-B electronic component of Carling 2GA721-D-4B-B

Switch Toggle ON None OFF SPST Lever Quick Conn 20A 277VAC 1491.4VA Panel Mount with Threads
Stock : 1

3SS-WSP9-M2-RE electronic component of Carling 3SS-WSP9-M2-RE

Switch Push Button OFF (ON) SPST Round Plunger 20VAC 20VDC 0.4VA Momentary Contact PC Pins Thru-Hole
Stock : 1

62111122-0-0-N electronic component of Carling 62111122-0-0-N

Rocker Switches ON-NONE-ON CRV RCKR
Stock : 1

62115919-0-0-N electronic component of Carling 62115919-0-0-N

Rocker Switches DPST ON-NONE-OFF
Stock : 1

2GM721-D-4B-B electronic component of Carling 2GM721-D-4B-B

Toggle Switches DPDT ON-OFF-ON
Stock : 1

2FB54-73/2 HEX electronic component of Carling 2FB54-73/2 HEX

Toggle Switches F-Series Toggle Switch
Stock : 1

2GM720-D-4B-B electronic component of Carling 2GM720-D-4B-B

Toggle Switches G-Series Toggle Switch
Stock : 1

6GG5M-73 electronic component of Carling 6GG5M-73

Toggle Switches
Stock : 0

Image Description
21215-00 electronic component of Eaton 21215-00

Circuit Breakers CIRCUIT BREAKER TYPE II 1
Stock : 265

4404.0009 electronic component of Schurter 4404.0009

Circuit Breakers 7A 0.25" QC Snap-in front
Stock : 215

0812050.ZXST electronic component of Littelfuse 0812050.ZXST

Circuit Breakers 50A
Stock : 1

Hot W51-A121B1-20 electronic component of TE Connectivity W51-A121B1-20

TE Connectivity P&B Circuit Breakers 20A RCKR ACT RED ILL
Stock : 1

1658-A21-00-P10-20A electronic component of ETA 1658-A21-00-P10-20A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

TR11-D-X-63-BB-2-N-10.0A electronic component of Altech TR11-D-X-63-BB-2-N-10.0A

Circuit Breakers TR11sup.prot.,wingD,bl.slid.w/
Stock : 1

1658-G21-00-S83-5A electronic component of ETA 1658-G21-00-S83-5A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

ETIMAT 6 1P D10 electronic component of ETI Polam ETIMAT 6 1P D10

Circuit breaker; 230/400VAC; Inom: 10A; Poles: 1; DIN; Charact: D
Stock : 0

ETIMAT P10 1P B6 electronic component of ETI Polam ETIMAT P10 1P B6

Circuit breaker; 230/400VAC; Inom: 6A; Poles: 1; DIN; Charact: B
Stock : 0

GV4AE11 electronic component of Schneider GV4AE11

Circuit Breakers TeSys BV4/GV4 Aux/Alarm Contact
Stock : 1

MM-Serie-Ss eries HYDRAULIC-MAGNETIC CIRCUIT BREAKER The M-Series is a low cost, miniature, hydraulic-magnetic circuit breaker which features a compact, space saving design, front panel snap-in mounting and a vertically mounted parallel pole configuration. It features various styling options to maximize your design flexibility. Choices include rocker, illuminated rocker, paddle and baton style handle actuators, push-to-reset and push-pull pushbutton actuators, as well as Visi-Rocker two color actuators. Our exclusive Rockerguard bezel helps prevent inadvertent actuation and a wiping contact mechanism assures long-term reliability. The M-Series circuit breakers are available with 1, 2 or parallel poles, 0.02 to 50 amp ratings, and 125 and 250VAC or 80VDC versions. With over 16 different time delays, 5 terminal styles, a variety of panel hardware, various colors, and legend imprinting, it assures suitability for most any application design. Resources: Configure a Complete Part Download CAD & Sales Drawing Product Highlights: Typical Applications: Parallel pole configuration fits in one rack unit Telecom/Datacom MIL-PRF-55629 Transportation MIL STD 202 compliant Marine MIL-PRF-39019F ingress protection Generators Sealed toggle actuator Power Supplies Compact design Medical Equipment Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales carlingtech.com www.carlingtech.com Application Support: team2 carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 M-Series Circuit Breaker General Specifications 2 Electrical Mechanical Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC Endurance 10,000 ON-OFF operations 6 (See Rating Tables.) per minute with rated Current and Current Ratings Standard current coils: 0.100, Voltage. 0.250, 0.500, 0.750, 1.00 thru 15.0 Trip Free All M-Series Circuit Breakers will in 1 amp increments, 18.0, 20.0, trip on overload, even when 25.0, 30.0. Other ratings available actuator is forcibly held in the ON - see Ordering Scheme. position. Auxiliary Switch Rating SPDT 7A 250VAC, 7A (Res) Trip Indication The actuator moves positively 28VDC, 4A (Ind.) 28VDC, 0.25A to the OFF position when an 80VDC (Res) (silver contacts), overload causes the circuit 0.1A 125VAC (gold contacts). breaker to trip. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Physical Number of Poles 1 or 2 Dielectric Strength UL, CSA 1500V, 50/60 Hz for one Internal Circuit Configs. Series with or without minute between all electrically Auxiliary Switch. isolated terminals. M-Series Switch Only with or without Circuit Breakers comply with the Auxiliary Switch. 8mm spacing and 3750 V 50/60Hz Weight Approximately 30 grams/pole dielectric requirements from (Approximately 1.07 ounces/pole) hazardous voltage to operator Standard Colors See Ordering Scheme accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Environmental Designed in accordance with requirements of specification Resistance, Impedance Values from Line to Load Terminal MIL PRF-55629 & MIL-STD-202G as follows: - based on Series Trip Circuit Breaker. Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per RESISTANCE PER POLE VALUES from Line to Load Terminals Method 213, Cond. I. Instantaneous (Values Based on Series Trip Circuit Breaker) curves tested at 80% of rated CURRENT TOLERANCE current. (AMPS) (%) Vibration Withstands 0.060 excursion from 10-55 Hz, and 10 Gs 55-500 0.10 - 20.0 25 Hz, at rated current per Method 20.1 - 50.0 35 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles + 25C to +65C, 80- 98% RH. Salt Spray Method 101, Condition A (90-95% RH 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles -55C to +25C to +85C to +25C). Pulse Tolerance Curves Operating Temperature -40 C to +85 C Chemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/ bushing openings *Manufacturer reserves the right to change product specification without prior notice. Email: sales carlingtech.com Application Support: team2 carlingtech.com Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com

Tariff Desc

CIRCUIT BREAKERS, AC AND/OR DC, having ALL of the following:
(a) current rating NOT greater than 400 A;
(b) single OR multiple pole;
(c) operating voltage NOT greater than 1 000 V AC
Op. 30.06.11 Dec. date 26.09.11 - TC 1121463
CARLING
Carling Technologies
Carling Technologies Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted