Product Information

EDT1411-NTC-2307

EDT1411-NTC-2307 electronic component of Cal Controls

Datasheet
THERMOSTAT, NTC, RELAY, 230VAC

Manufacturer: Cal Controls
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 86.6859 ea
Line Total: USD 86.69

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Wed. 01 May to Tue. 07 May

MOQ : 1
Multiples : 1

Stock Image

EDT1411-NTC-2307
Cal Controls

1 : USD 129.1314
5 : USD 104.1283
10 : USD 98.5718

     
Manufacturer
Product Category
Accuracy
Brand
Thermocouple Type
Operating Temperature Max
Operating Temperature Min
Output Voltage Max
Product Range
External Depth
External Length / Height
External Width
Hysteresis
Input Voltage Max
Material
Panel Cutout Size
Power Consumption
Supply Voltage Max
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
991.12C electronic component of Cal Controls 991.12C

TEMPERATURE CONTROLLER, 230VAC
Stock : 0

991.11C electronic component of Cal Controls 991.11C

TEMPERATURE CONTROLLER, 115VAC
Stock : 0

95001PA001 electronic component of Cal Controls 95001PA001

TEMPERATURE CONTROLLER, LOGIC
Stock : 0

E-NTC-APP-1.5P7 electronic component of Cal Controls E-NTC-APP-1.5P7

PROBE, NTC, PLASTIC SHELL, PVC CABLE
Stock : 0

E-NTC-APT-1.5T7 electronic component of Cal Controls E-NTC-APT-1.5T7

PROBE, NTC, THERMOPLASTIC SHELL&CABLE
Stock : 0

992.11C electronic component of Cal Controls 992.11C

TEMPERATURE CONTROLLER, 115VAC
Stock : 0

320050 electronic component of Cal Controls 320050

TEMPERATURE CONTROLLER, 24VAC
Stock : 0

3C0000407 electronic component of Cal Controls 3C0000407

COMMUNICATION BOARD, RS485
Stock : 0

Image Description
67L060-0368 electronic component of Sensata 67L060-0368

Thermostats TO-220 thermostat, close on rise
Stock : 1

3L09-12 electronic component of White-Rodgers 3L09-12

Thermostats Open 220, Close 180F Brd Mnt LimitControl
Stock : 1

3L09-15 electronic component of White-Rodgers 3L09-15

Thermostats Open 260, Close 230F Brd Mnt LimitControl
Stock : 1

66L070-0301 electronic component of Sensata 66L070-0301

Thermostats DIP thermostat, open on rise
Stock : 1

66L090-0475 electronic component of Sensata 66L090-0475

Thermostats DIP thermostat, open on rise
Stock : 1

67F110-0389 electronic component of Sensata 67F110-0389

Thermostats TO-220 thermostat, close on rise
Stock : 1

Hot 3455RC 01000237 electronic component of Honeywell 3455RC 01000237

Thermostats 1/2(L229:241/213:197
Stock : 1

TRS5-45BLRU electronic component of Kemet TRS5-45BLRU

Magnetic Reed Switches 45C 50W 140V Break Axial L Shape
Stock : 15

TRS3-0MSR01E electronic component of Kemet TRS3-0MSR01E

Thermostats 0C 35W 140V Make Axial L Type
Stock : 0

03F11 120 electronic component of White-Rodgers 03F11 120

Thermostats 1/2" Bimetal Disc Thermostat, Close On Rise, Range 113 To 127 ( F), 45 To 53 ( C), Differential 30 F, 17 C. Therm-O-Disc Style 10847, Type 36T22
Stock : 3

www.cal-controls.com EDT1411-NTC-230VAC DIGITAL DEFROST THERMOSTAT SN: XXXXXXXXX NTC SENSOR R W 123456 789 10 11 12 COMPRESSORCOMPRESSOR 1/2HP250V240VAC 8AAC Cos = 0.4 8RESISTIVEA 250V AC CosLOAD = 1 230V AC +10% -20% 50/60Hz 3VA Technical Specifications ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50C/-25 ... 70C (with no icing) Max. relative humidity 80%, up to 31C decreasing linearly 50% at 40C Rated pollution degree According to EN 60529 Front panel : IP60 Rear panel : IP20 Height Max. 2000m CAL EDT1411 THERMOSTAT Do not use the device in locations subject to corrosive and flammable gasses. Thank you for choosing the CAL EDT1411 thermostat. ELECTRICAL CHARACTERISTICS 230V AC +%10 -%20, 50/60Hz or 24V AC/DC %10, 50/60Hz or 12V AC/DC %10, 50/60Hz. * 34 x 77mm sized. Supply voltage Power consumption Max. 3VA * On-Off control. F Wiring * Single contact output for cooling control. 2.5mm screw-terminal connections. C Scale * NTC probe input for cold room temperature. -50.0 ... +110.0C (-58.0 ... +230.0F) * Offset value can be entered for NTC probe. SET Sensitivity/Accuracy 0.1C / 1C * Compressor protection parameters can be entered. Time Accuracy (%1-15sec) for hour unit, ( %1-1sec) for minute unit * In the case of probe failure, output state can be Indicator 4 digits, 12mm, 7 parts yellow LED selected on or off or periodical running. EMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. CAL EDT1411 * Upper and lower limits of the setpoint can be adjusted. The device is designed to operate in controlled electromagnetic environment) * Defrosting duration and interval can be adjusted. Safety requirements EN 61010-1: 2001 (Pollution degree 2, overvoltage category II) * 16 different warning tones. * Upper and lower limits of the alarm value can be adjusted depending on the setpoint value. OUTPUT * CE marked according to European Norms. COMPRESSOR For EDT1411-NTC-XX Relay: 250V AC, 8A (for resistive load), NO+NC 1/2 HP 240V AC Cos = 0.4 (for inductive load) For EDT1411-NTC-XXP Relay: 240V AC, 16A (for resistive load), NO Order Code : EDT1411-NTC- - 1 HP 230V AC Cos = 0.5 (for inductive load) 12 Life expectancy for relay For EDT1411-NTC-XX Mechanical 30.000.000 Electrical 100.000operation. For EDT1411-NTC-XXP Mechanical 30.000.000 Electrical 30.000operation. 2 - Output 1 - Supply Voltage P..........Relay-16A 230VAC...230V AC CONTROL None...Relay-8A 24............24V AC/DC Control type Single-setpoint control 12............12V AC/DC Control algorithm On-Off control Hysteresis Adjustable between 0.1 ... 20.0C. HOUSING Connection Diagram Housing type Suitable for panel mounting. Dimensions W77xH34xD70mm CAL EDT1411 is intended for installation in control panels. Make sure that the device is used Approx. 250g (after packing the device and a probe) Weight only for intended purpose. The electrical connections must be carried out by qualified staff Self extinguishing plastics Enclosure material and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. Depth Dimensions 8mm 70mm 85mm For removing mounting clamps: www.cal-controls.com www.cal-controls.com www.cal-controls.com F Push out the mounting clamp EDT1411-NTC-230VAC EDT1411-NTC-24 EDT1411-NTC-230VAC-P C in direction 1 as shown DIGITAL DEFROST THERMOSTAT DIGITAL DEFROST THERMOSTAT DIGITAL DEFROST THERMOSTAT SET in the figure below. Then, pull SN: XXXXXXXXX SN: XXXXXXXXX SN: XXXXXXXXX out the clamp in direction 2. CAL EDT1411 2 mounting mounting Panel Rubber clamp clamp gasket NTC NTC NTC SENSOR SENSOR SENSOR 1 Panel cut-out Note :1) Panel thickness W R W R W R 71mm should be maximum 123456 789 10 11 12 123456 789 10 11 12 123456 789 10 11 12 7 mm. 2) If there is no 60mm Equipment is protected throughout Holding screw free space at the back by DOUBLE INSULATION 0.4-0.5Nm. side of the device, it would be difficult to NOTE: Fuse Note: remove it from the SUPPLY: F 100 mA 1) Mains supply cords shall meet the requirements of Switch 250V AC panel IEC 60227 or IEC 60245. 7 Line 184-253V AC 230V AC 2) In accordance with the safety regulations, the power 50/60Hz 3VA 8 Neutral Supply supply switch shall bring the identification of the CAL CONTROLS LTD Fuse should relevant instrument and it should be easily Bury Mead Road, Hitchin, Herts, SG5 1RT, UK. Cable size: 1,5mm be connected accessible by the operator. Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales cal-controls.co.uk Web : www.cal-controls.com 1/3 EDT1411-E-06 Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. COMPRESSOR 250V AC 8A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA COMPRESSOR 250V AC 8A RESISTIVE LOAD 24V AC/DC 10% 50/60Hz 3VA COMPRESSOR 250V AC 16A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA 34mm 29mmFAHRENHEIT DEFROST COMPRESSOR LED Displayed process value in the run mode, parameter name or value in programming mode. LED LED When held down for 3 second in the run mode, manual defrost starts. After the specified time withD.dur parameter manual defrost finishes. When held down for 3 second manual defrost finishes before the F specified time ends. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode. When held down for a few C seconds, the change rate accelerates. SET When held down for 3 second in the run mode continuous mode starts. After the specified time withC.Con parameter this mode finishes. When held down for 3 second continuous mode finishes before the specified time ends. Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the CAL EDT1411 change rate accelerates. SET Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. While holding key, setpoint value of the selected parameter appears and by using and keys the value can be adjusted. Run Mode Error Messages Means, thermostat probe is short circuit or temperature value is SET SET Psc Process higher than the scale. 1000-22.0 Value -30.0 -29.9 -30.0 Means, thermostat probe is broken or temperature value is SET Pfa lower than the scale. While holding key COMPRESSOR setpoint value appears and by using and keys the value can be adjusted. If process value flashes and warning tone sounds, means, 23.5 measured value exceeds the adjusted alarm limit. If both keys are pressed, If both keys are pressed and held for 3 seconds, run mode is entered. programming mode is entered. *Note: To stop warning tone, press any key. Programming Mode RE CP DE Al SE The lower limit Delay time for the compressor Defrosting duration. Limit for Access code for security menu. of the setpoint. after power is on. lower alarm level. This parameter should be 321 . D.dur A.lol C.pon R.lol S.Cod The upper limit Delay time required for Interval between Security parameter Limit for of the setpoint. the compressor to restart defrost cycles. for refrigeration menu upper alarm level. R.uPl C.Fos D.int A.uPl A.-re following a stop. The offset value Continuous-on mode duration Display configuration Time delay to display Security parameter for the refrigeration. for the compressor. during defrost alarm message after for menu of compressor control A.dFl R.off C.Con D.dsp A.-Cp alarm is on. Switch hysteresis on time for the compressor Delay time for display Switch hysteresis Security parameter for compressor. output in the case of real temperature after for alarm. for menu of defrost control R.Hys C.ppn D.drE A.HYS A.-de probe failure. defrost is over. Temperature unit oFF time for the compressor Defrosting after Alarm configuration Security parameter output in the case of power is on. for menu of alarm control Unit A.Set C.ppF D.Pon A.-al probe failure. Display resolution Delay time for defrosting Time delay to display Security parameter after power is on. alarm message after for refrigeration setpoint value DrES D.dPo A.dpo A.rE.S. power is on. Type of buzzer sound. SonD 2/3 EDT1411-E-06

Tariff Desc

9032.10.00 Automatic regulating or controlling instruments and apparatus. Thermostats

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted