Product Information

LPMP/2 400V

LPMP/2 400V electronic component of Broyce Control

Datasheet
RELAY, VOLTAGE SENSE, DPDT, 5A, 400VAC

Manufacturer: Broyce Control
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 193.3042 ea
Line Total: USD 193.3

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 26 Apr to Thu. 02 May

MOQ : 1
Multiples : 1

Stock Image

LPMP/2 400V
Broyce Control

1 : USD 149.5549
5 : USD 135.6985
10 : USD 132.9367

     
Manufacturer
Product Category
Brand
Contact Configuration
Contact Current
Relay Mounting
Contact Voltage Vac
Relay Terminals
Contact Voltage Vdc
Supply Voltage Max
Power Consumption
Svhc
Approvals Standards
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
LXCVR 230V electronic component of Broyce Control LXCVR 230V

TIME DELAY RELAY, SPDT, 0.2-10S, 230VAC
Stock : 0

LBVR/A  12-24VDC electronic component of Broyce Control LBVR/A 12-24VDC

BATTERY VOLTAGE RELAY, SPDT, 12-24VDC
Stock : 248

LEDO 12-230V AC/DC electronic component of Broyce Control LEDO 12-230V AC/DC

DELAY-ON-OPERATE TIMER, 0.1S-100H, SPDT
Stock : 76

LEIN 12-230V AC/DC electronic component of Broyce Control LEIN 12-230V AC/DC

INTERVAL ONE SHOT TIMER, 0.1S-100H, SPDT
Stock : 0

LESW 12-230V AC/DC electronic component of Broyce Control LESW 12-230V AC/DC

DELAY ON RELEASE TIMER, 0.1S-100H, SPDT
Stock : 190

LRTM/2 12-230V AC/DC electronic component of Broyce Control LRTM/2 12-230V AC/DC

DELAYED PULSE/OFF/ON TIMER, DPDT
Stock : 1

LXCVR 115V electronic component of Broyce Control LXCVR 115V

RELAY, VOLTAGE SENSE, SPDT, 8A, 115VAC
Stock : 12

LMCCR-10A electronic component of Broyce Control LMCCR-10A

RELAY, CURRENT SENSE, SPDT, 8A, 250VAC
Stock : 0

LMCCR-2A electronic component of Broyce Control LMCCR-2A

RELAY, CURRENT SENSE, SPDT, 8A, 250VAC
Stock : 0

LMCVR-500V electronic component of Broyce Control LMCVR-500V

RELAY, VOLTAGE SENSE, SPDT, 8A, 230VAC
Stock : 12

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

Type: LPMP/2 Phase Asymmetry, Failure, Sequence, Under and Over Voltage plus Restart Delay Terminal Compact 17.5mm DIN rail housing Protection Microprocessor based to IP20 True R.M.S. monitoring measuring phase to phase (3-wire) or phase to neutral (4-wire) voltages Selectable nominal voltages to suit most popular 3-wire or 4-wire supply voltages Monitors own supply, detects phase asymmetry and if fixed Under or Over voltage trip levels are exceeded 1 Detects incorrect phase sequence, phase loss and neutral loss Adjustment for phase asymmetry/unbalance Adjustment for Restart delay Adjustment for Time delay DPDT relay output 5A Dims: to DIN Green LED indication for supply status 43880 1 Red LED indication for relay status Only when 4-wire monitoring selected W. 17.5mm FUNCTION DIAGRAM TECHNICAL SPECIFICATION Supply/monitoring voltage Un Asymm. % Over trip Monitored 3-wire monitoring 4-wire monitoring (L1, L2, L3, (N)): 3~ Supply Hyst. Hyst. Phases reversed 380, 400, 415V AC 220, 230, 240V AC L1-L2 L1 Frequency range: 48 63Hz L2-L3 L2 Supply variation: 243- 540V AC (L>L) L3-L1 L3 Overvoltage category: III (IEC 60664) N Rated impulse withstand voltage: 4kV (1.2/50S) IEC 60664 Hyst. Power consumption (max.): 2.5VA Under trip Monitoring mode: Asymmetry, Under and Over voltage Output Trip levels: LPMP 20816 18 Under 2 : Fixed 2% see below 15 Under: Fixed 90% of Un 16 Over: Fixed 110% of Un 28 Asymmetry: 2 8% 25 26 Measuring ranges: Nominal (Un) Under 2 Under Over 3-wire (L>L) 380V 243V 342V 418V t Td Td t Td t Td t Td t Td Td r r 400V 256V 360V 440V 415V 265V 374V 457V 4-wire (L>N) 220V 140V 198V 242V INSTALLATION AND SETTING 230V 147V 207V 253V 240V 153V 216V 264V BEFORE INSTALLATION, ISOLATE THE SUPPLY. Hysteresis: 2% of trip level (factory set) Connect the unit as required. The Connection Diagram below shows a typical installation, whereby the supply to a load is Setting accuracy: 3% being monitored by the Phase monitoring relay. If a fault should occur (i.e. fuse blowing), the relay will de-energise and Repeat accuracy: 0.5% at constant conditions assuming control of the external Contactor, de-energise the Contactor as well. Immunity from micro power cuts: <50ms Only connect the Neutral if available and 4-wire monitoring is required. Response time (t ): r 50ms Applying power. Time delay (t): 0.2 10s ( 5%) Set the Nominal (Un) voltage selector to match that of the voltage being monitored. Note: actual delay (t) = adjustable delay + response time Set the Asymmetry % adjustment to maximum. Restart/Power on delay (Td): 1s 500s Reset time: 50 100ms Set the Delay (t) and Restart delay adjustments to minimum. Apply power and the green Power supply LED will illuminate. The red LED will illuminate and relay energise after Power on indication: Green LED the short delay period (Td). Relay status indication: Red LED Refer to the troubleshooting table if the unit fails to operate correctly. Ambient temperature: -20 to +60C Setting the unit (with power applied). Relative humidity: +95% max. Assuming all phases are perfectly balanced it should be possible to set the Asymmetry (%) adjustment to minimum which Output (15, 16, 18 / 25, 26, 28): DPDT relay will ensure that it will detect the smallest of changes in the phase voltages. However, if large changes in phase voltages are Output rating: AC1 250V 5A (1250VA) likely, then the Asymmetry (%) setting should be increased. AC15 250V 2A The formula used for calculating phase asymmetry is shown on the right at the bottom of the Technical Specification. DC1 25V 5A (125W) Set the Delay (t) and Restart delay as required. (Note that the delay t is only effective should any phases exceed the Electrical life: 150,000 ops at rated load nd set trip point. However, if the supply drops below the 2 under voltage trip level, any set time delay is automatically Dielectric voltage: 2kV AC (rms) IEC 60947-1 cancelled and the relay de-energises immediately). Rated impulse withstand voltage: 4kV (1.2/50S) IEC 60664 Troubleshooting. Housing: Orange flame retardant UL94 The table below shows the status of the unit during a particular fault condition. Weight: 90g Mounting option: On to 35mm symmetric DIN rail to BS EN 60715 or direct Supply fault Green LED Red LED Relay surface mounting via 2 x M3.5 or 4BA screws using the black Phase or neutral missing LEDs flash alternately De-energised clips provided on the rear of the unit. 2 Phase or neutral restored (during restart timing) On Flashing (x2) De-energised for delay (Td) Terminal conductor size 2 x 2.5mm solid or stranded Phases reversed (no delay) Flashing Off De-energised Approvals: Conforms to IEC. CE, and RoHS Compliant. Under or Over voltage condition (during timing) On Flashing Energised for delay (t) EMC: Immunity: EN 61000-6-2 Emissions: EN 61000-6-4 Under or Over voltage condition (after timing) On Off De-energised Note: Voltage returned from Under/Over volt. (during restart timing) On Flashing (x2) De-energised for delay (Td) L>L has the same meaning as phase to phase and L>N, the same as phase to neutral Phase asymmetry trip point exceeded (during timing) On Flashing Energised for delay (t) Asymmetry formula Phase asymmetry trip point exceeded (after timing) On Off De-energised Maximum deviation from V ave Phase asymmetry below trip point (during restart timing) On Flashing (x2) De-energised for delay (Td) Asymmetry = x100% V ave Phases < fixed under trip level 2 On Off De-energised ANSI/NEMA MG 1-2001 where V is the average of the three phases ave Note that Phase asymmetry can also referred to as Phase unbalance CONNECTION DIAGRAM SETTING DETAILS DIMENSIONS 1. Power supply status (Green) 89 (exc. clips) LED 67.5 2. Relay output / Timing status 45 (Red) LED 3. Nominal (Un) voltage selector 4. Restart delay adjustment 5. Delay (t) adjustment 6. Asymmetry % trip Insert screwdriver to release clips adjustment Withdraw clips fully when surface mounting 92 (+/- 1mm) all dimensions in mm. Broyce Control Ltd., Pool Street, Wolverhampton, West Midlands WV2 4HN. England LPMP 2-1-A.DOCX XXXXX Tel: +44 (0) 1902 773746 Fax: +44 (0) 1902 420639 Email: sales broycecontrol.com Web: www.broycecontrol.com The Information provided in this literature is believed to be accurate (subject to change without prior notice) however, use of such information shall be entirely at the users own risk. 29 49.5 66.5X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Broyce Control manufacturer: Other Similar products are found below : LART 12-230V AC/DC LXCVR 230V LBVR/A 12-24VDC LMCCR-10A LESW 12-230V AC/DC

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted