Product Information

R38-LARR

R38-LARR electronic component of Ascon

Datasheet
Module: regulator; Pt100; temperature; SPDT; SPDT; on panel; 0÷50°C

Manufacturer: Ascon
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 104.949 ea
Line Total: USD 104.95

1 - Global Stock
Ships to you between
Tue. 23 Apr to Mon. 29 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
5 - Global Stock


Ships to you between Tue. 23 Apr to Mon. 29 Apr

MOQ : 1
Multiples : 1

Stock Image

R38-LARR
Ascon

1 : USD 102.271
10 : USD 98.332

     
Manufacturer
Product Category
Controlled Parameter
Mounting
The Programming Method
Kind Of Temperature Sensor
Controlled Parameter Range
Kind Of Output 1
Output 1 Electrical Parameters
Kind Of Output 2
Output 2 Electrical Parameters
Regulation For Output 1
Regulation For Output 2
Kind Of Display Used
Type Of Module
Operating Temperature
Supply Voltage
Mounting Hole Diameter
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
K39-LCRR electronic component of Ascon K39-LCRR

Module: regulator; temperature; on panel; Programming: keypad
Stock : 2

K49T-HCRR electronic component of Ascon K49T-HCRR

Module: regulator; temperature; SPST-NO; SPST-NO; on panel
Stock : 1

R38-LAOO electronic component of Ascon R38-LAOO

Module: regulator; Pt100; temperature; SSR; SSR; on panel; 0÷50°C
Stock : 2

K85-HERR electronic component of Ascon K85-HERR

Module: regulator; temperature; SPDT; SPDT; DIN; 250VAC/8A
Stock : 1

K39P-LCRR electronic component of Ascon K39P-LCRR

Module: regulator; temperature; SPDT; SPDT; on panel; 250VAC/8A
Stock : 1

K85T-LCRR electronic component of Ascon K85T-LCRR

Module: regulator; temperature; SPDT; SPDT; DIN; 250VAC/8A; 24VAC
Stock : 1

K38-FCOO electronic component of Ascon K38-FCOO

Module: regulator; temperature; SSR; SSR; on panel; 10mA/10VDC
Stock : 1

K38-LCOO electronic component of Ascon K38-LCOO

Module: regulator; temperature; SSR; SSR; on panel; 10mA/10VDC
Stock : 2

E33NDRR-BVVIWBE electronic component of Ascon E33NDRR-BVVIWBE

Module: regulator; NTC; temperature; SPST-NO; OUT 2:SPDT; on panel
Stock : 13

TLK43-LVROO electronic component of Ascon TLK43-LVROO

Module: regulator; temperature; 0/2-10V; OUT 2: SPST-NO; on panel
Stock : 2

Image Description
ZAD-ECO-V2 electronic component of Cobi ZAD-ECO-V2

Module: process analogue calibrator; Vol.output:0÷10V; panel
Stock : 8

TK4H-14SC electronic component of Autonics TK4H-14SC

Module: regulator; temperature; SSR; SSR, analogue; on panel; IP65
Stock : 1

TX4S-14R electronic component of Autonics TX4S-14R

Module: regulator; temperature; SPST-NO; SPST-NO; on panel; IP50
Stock : 20

TC4Y-12R electronic component of Autonics TC4Y-12R

Module: regulator; temperature; SPST-NO; SSR; on panel; 250VAC/3A
Stock : 0

TP-1W electronic component of Etron TP-1W

Module: regulator; NTC; temperature; NO, relay; for wall mounting
Stock : 1

TF31-31H electronic component of Autonics TF31-31H

Module: regulator; NTC, RTD; temperature; SPDT; SPST-NO; panel
Stock : 1

TFD-3 electronic component of Autonics TFD-3

Module: display; Body dim:31.5x52x12mm; Cable len:3m
Stock : 3

TX4M-B4R electronic component of Autonics TX4M-B4R

Module: regulator; temperature; SPST-NO; SPST-NO; on panel; IP50
Stock : 2

AR621/S electronic component of Apar AR621/S

Module: regulator; temperature; SSR; panel; 11VDC/25mA NPN; 0÷50°C
Stock : 1

E33NDRR-BVVIWBE electronic component of Ascon E33NDRR-BVVIWBE

Module: regulator; NTC; temperature; SPST-NO; OUT 2:SPDT; on panel
Stock : 13

R38 Entry-level controller with super-simplified programming Ver y few parameters APPLICATION SECTORS Input f or TC, J or K, RTD, PTC, NTC Soldering/sealing Resolution 0.1C with automa tic scale change (auto-rang ing) Glueing (hot glue) Sensitive Touch ke yboard Packaging and blister packing Up to 2 SPDT rela y outputs machines Switching Power Suppl y 100... 240 VAC T-shirt print Control: - PID single action with Autotuning Maintening Ovens - ON/OFF single action Thermostatic Baths - ON/OFF double action (H/C) (neutral zone) - ON/OFF SP1 drives Out 1 - SP2 drives Out 2 Parameters protection with programmable password or Keyboard Lock Soft start or Start up dela y (od) function Automa tic or stand-b y Mode Compressor protection time Direct access to the Set PointR38 SENSITIE Tv OuCH ON/O SP1 dff RIESv OuT 1 - SP2 dRIESv OuT 2 Innova tive solution f or the prog ramming through an ergonomic ke yboard which In some systems with an ON/OFF control 2 dif ferent actua tors are used f or carr ying out the same action. uses the technolog y Sensitive Touch. A typical example is tha t of two sta ge burners, but a pplica tions using a This system is constituted b y a e-fied sensor ke yboard tha t guarantees a com- rejection element (e.g. hot wa ter or va pour) as a resource f or a second plete protection from dust and liquids in ever y critical environmental situa tions. process are not rare. In this case one of the 2 actua tors is used just f or integ ra ting the energ y produced from the first and theref ore accelera te the regula ting action when the START uP dELA y measurement is far of f from the set point (machine start up, strong varia tions in charge, etc.). The most common a pplica tion of this function is aimed a t a voiding, a t system In these cases it is prefera ble to keep the set points (the working points) of the start up, tha t total consumption of the current exceeds the amount f oreseen two actua tors separa te f or better control of the system. in the contract with the energ y provider. The aim, theref ore, is to a void the Example: Oven with two-stage burner overcurrent protective device from being activa ted. SP1 activa tes the first sta ge while SP2 activa tes the second sta ge. At start up all machines are a t room tempera ture and theref ore require the SP1 = 300C maximum volta ge f or a period of time tha t can be quite long. SP2 = 250C By setting the dela y in such a wa y tha t some machines start immedia tel y while - When the measurement is lower than 250C the instrument activa tes others activa te the control onl y when the first gear is up to speed (i.e. when both sta ges. there required volta ge has decreased to the lowest values), the request f or - When the measurement exceeds 250C, the instrument will onl y use the energ y of the various machines is obtained over time considera bl y reducing the first sta ge. maximum volta ge consumed in this phase. KEybOARd LOCK fuNCTION SOTf START This function makes it possible to elimina te thermal shock and mechanical In man y places and a bove all in public places such as bars, small stress (due to dila ta tion) tha t a system undergoes during start up. supermarkets, etc., the final user is not mana gement but ra ther the customer. In other cases the aim is tha t of slowing down the increase in tempera ture in However, the instrument must be a vaila ble to the mana ger so the correct such a wa y tha t this can spread itself out evenl y inside the ma terial, especiall y functioning of the machine can be checked and an y modifica tions made to its when the machine is equipped with stirrers tha t cannot be started up a t room settings. tempera ture. In these cases it is essential tha t the working of the ke yboard can be inhibited thus preventing the machine from being tampered with b y an unauthorized person. It is however, still possible f or the mana ger to reactiva te the ke yboard f or the time necessar y f or carr ying out modifica tions. COmPRESSOR PROTECTION TImE ACCESSORIES Some actua tors, f or example compressors, pumps, some burners, etc., A01 - Programming key cannot be turned of f or turned back on too quickl y f or their constructive Makes it possible to: characteristics. In other words after a start up period the y must be kept turned - Store the configura tion of an instrument of f f or a minimum amount of time to allow the system to recover the conditions to transfer it to other instruments necessar y f or it to be turned back on. - Transfer a configura tion to a PC To protect the working life of the actua tor it theref ore becomes essential to - Memorize a configura tion recorded in a PC be a ble to activa te a timer tha t guarantees the minimum time between the - Let the instrument converse directl y with a PC. switching of f of the machine and the f ollowing start up.

Tariff Desc

8542.3 - Electronic integrated circuits:
8542.31.00 -- Processors and controllers, whether or not combined with memories, converters, logic circuits, amplifiers, clock and timing circuits, or other circuits
Monolithic integrated circuits:
.Digital:
61 No ..Linear/analogue and peripheral integrated circuits, timers, voltage regulators, A/D and D/A converters, telecommunication and modem integrated circuits, other than board level products
62 No ..Other
63 No Hybrid integrated circuits
64 No Multichip integrated circuits

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted