Product Information

OKX-T/16-D12P-C

Product Image X-ON

Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 16A 80W 10-Pin SIP Module Tray
Manufacturer: Murata


Price (Ex GST)

From 20.0095

12 - Global Stock
Ships to you between
Wed. 09 Dec to Tue. 15 Dec
MOQ: 1 Multiples:
Pack Size :   1
Availability Price Quantity
12 - Global Stock


Ships to you between Wed. 09 Dec to Tue. 15 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 20.0095

Buy
12 - Global Stock


Ships to you between Wed. 09 Dec to Tue. 15 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 20.0095

Buy
         
Manufacturer
Murata
Product Category
Isolated DC/DC Converters
Category
Isolated Dc/Dc Converters
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image OKX-T/5-D12P-C
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 5A 25.5W 5-Pin SIP
Stock : 375
Stock Image OKY2-T/16-D12N-C
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 16A 80W 7-Pin T/R
Stock : 197
Stock Image OKY2-T/10-D12P-C
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 10A 50W 7-Pin T/R
Stock : 500
Stock Image OKX-T/16-W5N-C
Non-Isolated DC/DC Converters 5Vin 0.7525-3.63Vout
Stock : 164
Stock Image OKX-T/3-D12N-C
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 3A 15.3W 5-Pin SIP
Stock : 521
Stock Image OKX-T/5-W5N-C
Module DC-DC 5VIN 1-OUT 0.7525V to 3.6V 5A 16.5W 5-Pin SIP
Stock : 97
Stock Image OKX-T/3-W5N-C
Module DC-DC 5VIN 1-OUT 0.7525V to 3.6V 3A 10.1W 5-Pin SIP
Stock : 200
Stock Image OKX-T/5-D12N-C
Non-Isolated DC/DC Converters 12Vin 0.75-5.5Vout 5A Neg logic SIP
Stock : 362
Image Description
Stock Image NCS3S1205SC
Module DC-DC 12VIN 1-OUT 5V 0.6A 3W 6-Pin Tube
Stock : 9
Stock Image NCS3S4803SC
Module DC-DC 48VIN 1-OUT 3.3V 0.7A 2.31W 6-Pin SIP Module
Stock : 25
Stock Image OKX-T/3-D12N-C
Module DC-DC 12VIN 1-OUT 0.7525V to 5.5V 3A 15.3W 5-Pin SIP
Stock : 521
Stock Image NCS3S4805SC
Module DC-DC 48VIN 1-OUT 5V 0.6A 3W 6-Pin SIP Module
Stock : 91
Stock Image OKX-T/5-W5N-C
Module DC-DC 5VIN 1-OUT 0.7525V to 3.6V 5A 16.5W 5-Pin SIP
Stock : 97
Stock Image NCS6D1205C
Isolated DC/DC Converters 6W 12Vin +/-5Vout +/-0.6A DIP
Stock : 26
Stock Image NCS6D1212C
Module DC-DC 12VIN 2-OUT 12V/-12V 0.25A/-0.25A 6W 8-Pin Tube
Stock : 13
Stock Image NCS6D4805C
Module DC-DC 48VIN 2-OUT 5V/-5V 0.6A/-0.6A 6W 8-Pin Tube
Stock : 25
Stock Image OKY-T/5-D12N-C
Module DC-DC 12VIN 1-OUT 0.75V to 5.5V 5A 25W 5-Pin SMT T/R
Stock : 1980
Stock Image NCS6D4812C
Module DC-DC 48VIN 2-OUT 12V/-12V 0.25A/-0.25A 6W 8-Pin Tube
Stock : 29

OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Package C86, Output Input Pinout P84 IOUT Regulation (Max.) Ef? ciency On/Off Sequence/ R/N Iin, Iin, Case Logic Tracking VOUT (Amps Power (mVp-p) Vin Nom. Range no load full load Dimensions are Model Number ? (Volts) max) (Watts) Max. ? Line Load (Volts) (Volts) ? (mA) (Amps) Min. Typ. in inches (mm) 2.0x0.5x0.37 OKX-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. yes (50.8x12.7x9.4) ? The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ? Use adequate ground plane and copper thickness adjacent to the converter. ? All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25 deg.C. unless ? Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. otherwise noted. Output capacitors are 1 ?F ceramic and 10 ?F electrolytic in parallel. Input cap is 22 ?F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE Lx OK X 2-/T 16 - D12 P - C RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS Okami Non-isolated PoL exemption 7b?lead in solder) SIP Mount Pin Length Option Sequence/Tracking Blank = Standard pin length Blank = Not installed, delete pin 9 L6 = Pin length 0.138 inches (3.5mm)* 2 = Installed, add pin 9 *Special quantity order is required; samples available Trimmable Output Voltage Range with standard pin length only. D12 Models = 0.7525-5.5V On/Off Logic Maximum Rated Output P = Positive Logic Note: Current in Amps N = Negative Logic Some model number combinations may not be available. See website or contact your local Murata sales Input Voltage Range representative. D12 = 8.3-14V www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 2 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Package C86, Output Input Pinout P84 IOUT Regulation (Max.) Ef? ciency On/Off Sequence/ R/N Iin, Iin, Case Logic Tracking VOUT (Amps Power (mVp-p) Vin Nom. Range no load full load Dimensions are Model Number ? (Volts) max) (Watts) Max. ? Line Load (Volts) (Volts) ? (mA) (Amps) Min. Typ. in inches (mm) 2.0x0.5x0.37 OKX-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. yes (50.8x12.7x9.4) ? The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ? Use adequate ground plane and copper thickness adjacent to the converter. ? All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25 deg.C. unless ? Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. otherwise noted. Output capacitors are 1 ?F ceramic and 10 ?F electrolytic in parallel. Input cap is 22 ?F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE Lx OK X 2-/T 16 - D12 P - C RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS Okami Non-isolated PoL exemption 7b?lead in solder) SIP Mount Pin Length Option Sequence/Tracking Blank = Standard pin length Blank = Not installed, delete pin 9 L6 = Pin length 0.138 inches (3.5mm)* 2 = Installed, add pin 9 *Special quantity order is required; samples available Trimmable Output Voltage Range with standard pin length only. D12 Models = 0.7525-5.5V On/Off Logic Maximum Rated Output P = Positive Logic Note: Current in Amps N = Negative Logic Some model number combinations may not be available. See website or contact your local Murata sales Input Voltage Range representative. D12 = 8.3-14V www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 2 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters Performance and Functional Speci? cations Short Circuit Duration Continuous, no damage See Note 1 (output shorted to ground) Prebias Startup Converter will start up if the external Input output voltage is less than Vset Input Voltage Range See Ordering Guide and Note 7. Dynamic Load Response 75 ?Sec max. to within ?2% of ? nal value Start-Up Voltage 7.75V (50-100% load step, di/dt=2.5A/?Sec) Undervoltage Shutdown (see Note 15) 7.50V Environmental Overvoltage Shutdown None Operating Temperature Range (Ambient) Re? ected (Back) Ripple Current (Note 2) 25 mA pk-pk See derating curves -40 to +85 deg. C. with derating (Note 9) Internal Input Filter Type Capacitive Operating PC Board Temperature -40 to +100 deg. Celsius max., Recommended External Fuse 15A no derating (12) Reverse Polarity Protection N/A. See fuse information Storage Temperature Range -55 to +125 deg. C. Input Current: Thermal Protection/Shutdown +130 deg. Celsius Full Load Conditions See Ordering Guide Relative Humidity to 85%RH/+85 deg. C., non-condensing 2 Inrush Transient 0.4 A Sec. Shutdown Mode (Off, UV, OT) 5 mA Physical Output in Short Circuit 100 mA Outline Dimensions See Mechanical Speci? cations No Load 80 mA Weight 0.2 ounces (5.6 grams) Low Line (Vin=Vmin, Vout=Vnom) 10.2 A. (OKX-T/16-D12), 6.34A (OKX-T/10-D12) Electromagnetic Interference Designed to meet FCC part 15, class B, EN55022 and CISPR22 class B conducted Remote On/Off Control (Note 5) and radiated (may need external ? lter) Negative Logic (?N? model suf? x) ON = Open pin or ground to +0.3V. max. OFF =+2.5V min. to + Vin (max) Restriction of Hazardous Substances RoHS-6 (does not claim EU RoHS Positive Logic (?P? model suf? x) ON = Open pin (internally pulled up) to exemption 7b?lead in solder) +Vin max. Absolute Maximum Ratings OFF = Ground pin to +0.3V. max. Current 1 mA max. Input Voltage (Continuous or transient) 0 V.to +15 Volts max. (D12 models) Tracking/Sequencing (OKX ?2? models) On/Off Control 0 V. min. to +Vin max. Slew Rate 2 Volts per millisecond, max. Input Reverse Polarity Protection See Fuse section Tracking accuracy, rising input Vout = +/-100 mV of Sequence In Output Current (Note 7) Current-limited. Devices can withstand a Tracking accuracy, falling input Vout = +/-200 mV of Sequence In sustained short circuit without damage. General and Safety The outputs are not intended to accept appreciable reverse current. Ef? ciency See Ordering Guide Storage Temperature -55 to +125 deg. C. Switching Frequency 300 KHz ? 25 kHz Lead Temperature See soldering speci? cations Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal (On/Off to Vout regulated) 8 mSec for Vout=nominal Isolation Notisolated Absolute maximums are stress ratings. Exposure of devices to greater than any of any Safety Designed to meet UL/cUL 60950-1, of these conditions may adversely affect long-term reliability. Proper operation under CSA-C22.2 No. 60950-1, IEC/EN 60950-1 conditions other than those listed in the Performance/Functional Speci? cations Table is not implied nor recommended. Calculated MTBF per Telcordia SR-232 (4a) 6.54 MHours (OKX2-T/16-D12P) Calculated MTBF per MIL-HDBK-217F (4b) 5.3 MHours (OKX2-T/16-D12P) Speci? cation Notes: Output (1) Specifications are typical at +25 deg.C, Vin=nominal (+12V. for D12 models), Vout=nominal (+5V for D12 models), full load, external caps and natural convection unless otherwise indicated. Extended tests at higher Output Voltage Range See Ordering Guide power must supply substantial forced airflow. Minimum Loading No minimum load All models are tested and specified with external 1 ?F paralleled with 10 ?F ceramic/tantalum output capacitors and a 22 ?F external input capacitor. All capacitors are low ESR types. These capacitors are Accuracy (50% load, untrimmed) ?2 % of Vnominal necessary to accommodate our test equipment and may not be required to achieve specified performance Voltage Output Range (Note 13) See Ordering Guide in your applications. However, Murata Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec under no-load conditions. Overvoltage Protection (Note 16) None (2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Temperature Coef? cient ?0.02% per oC of Vout range Cin=2 x 100 ?F tantalum, Cbus=1000 ?F electrolytic, Lbus=1 ?H. Ripple/Noise (20 MHz bandwidth) See Ordering Guide and note 8 (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total Line/Load Regulation See Ordering Guide and note 10 RMS current over time does not exceed the Derating curve. Maximum Capacitive Loading (Note 14) (4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2, Cap-ESR=0.001 to 0.01 Ohms 1,000 ?F ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection. Cap-ESR >0.01 Ohms 5,000 ?F (4b) Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign, Tambient=+25 deg.C, full Current Limit Inception (Note 6) 30 Amps (OKX2-T/16-D12) output load, natural air convection. (98% of Vout setting, after warm up) 25 Amps (OKX2-T/10-D12) (5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed Short Circuit Mode +Vin. Short Circuit Current Output 2 A (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected Protection Method Hiccup autorecovery upon overload setting. removal. (Note 7) www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 3 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Package C86, Output Input Pinout P84 IOUT Regulation (Max.) Ef? ciency On/Off Sequence/ R/N Iin, Iin, Case Logic Tracking VOUT (Amps Power (mVp-p) Vin Nom. Range no load full load Dimensions are Model Number ? (Volts) max) (Watts) Max. ? Line Load (Volts) (Volts) ? (mA) (Amps) Min. Typ. in inches (mm) 2.0x0.5x0.37 OKX-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. yes (50.8x12.7x9.4) ? The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ? Use adequate ground plane and copper thickness adjacent to the converter. ? All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25 deg.C. unless ? Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. otherwise noted. Output capacitors are 1 ?F ceramic and 10 ?F electrolytic in parallel. Input cap is 22 ?F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE Lx OK X 2-/T 16 - D12 P - C RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS Okami Non-isolated PoL exemption 7b?lead in solder) SIP Mount Pin Length Option Sequence/Tracking Blank = Standard pin length Blank = Not installed, delete pin 9 L6 = Pin length 0.138 inches (3.5mm)* 2 = Installed, add pin 9 *Special quantity order is required; samples available Trimmable Output Voltage Range with standard pin length only. D12 Models = 0.7525-5.5V On/Off Logic Maximum Rated Output P = Positive Logic Note: Current in Amps N = Negative Logic Some model number combinations may not be available. See website or contact your local Murata sales Input Voltage Range representative. D12 = 8.3-14V www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 2 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series www.murata-ps.com Adjustable DOSA 10/16-Amp SIP DC/DC Converters FEATURES Typical unit ?? Non-isolated SIP POL DC/DC power module ?? 8.3-14Vdc input voltage range ?? Programmable output voltage from 0.7525-5.5Vdc ?? 10 Amp (T/10) or 16 Amp (T/16) output current PRODUCT OVERVIEW models The OKX-T/10 and -T/16 series are miniature ef? cient Point of Load (POL) module features pro- ?? Drives 1000 ?F ceramic capacitive loads SIP non-isolated Point-of-Load (POL) DC/DC power grammable output voltage and On/Off control. An converters for embedded applications. The module optional Sequence/Tracking input allows controlled ?? High power conversion ef? ciency 94.5% at 3.3 is fully compatible with Distributed-power Open ramp-up and ramp-down outputs. The Sense input Vout Standards Alliance (DOSA) industry-standard provides load compensation. These converters also ?? Outstanding thermal derating performance speci? cations (www.dosapower.com). Applications include under voltage lock out (UVLO), output short ?? Over temperature and over current protection include powering CPU?s, datacom/telecom systems, circuit protection, over-current and over tempera- programmable logic and mixed voltage systems. ture protections. ?? On/Off control, Sense and optional Sequence/ The wide input range is 8.3 to 14 Volts DC. Two These units are designed to meet all standard Tracking input maximum output currents are offered, 10 Amps UL/EN/IEC 60950-1 safety and FCC EMI/RFI ?? UL/EN/IEC 60950-1 safety (T/10 models) or 16 Amps (T/16 models). Based emissions certi? cations and RoHS-6 hazardous ?? Industry-standard (DOSA) SIP format on ? xed-frequency synchronous buck converter substance compliance. ?? RoHS-6 hazardous substance compliance switching topology, the high power conversion Connection Diagram +Vin +Vout t4XJUDIJOH F1 On/Off Sense Control t' JMUFST Controller t$VSSFOU4FOTF External Trim DC Power Reference and Open = On Source Error Ampli?er Closed = Off (Positive On/Off) Common Common Sequence/Tracking (optional) Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See speci? cations. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 1 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Package C86, Output Input Pinout P84 IOUT Regulation (Max.) Ef? ciency On/Off Sequence/ R/N Iin, Iin, Case Logic Tracking VOUT (Amps Power (mVp-p) Vin Nom. Range no load full load Dimensions are Model Number ? (Volts) max) (Watts) Max. ? Line Load (Volts) (Volts) ? (mA) (Amps) Min. Typ. in inches (mm) 2.0x0.5x0.37 OKX-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12P-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/10-D12N-C 0.7525-5.5 10 50 40 ?0.15% ?0.25% 12 8.3-14 80 4.41 93% 94.5% Neg yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. no (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12P-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Pos. yes (50.8x12.7x9.4) 2.0x0.5x0.37 OKX2-T/16-D12N-C 0.7525-5.5 16 80 40 ?0.15% ?0.25% 12 8.3-14 80 7.09 92.5% 94% Neg. yes (50.8x12.7x9.4) ? The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V. ? Use adequate ground plane and copper thickness adjacent to the converter. ? All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25 deg.C. unless ? Ripple and Noise (R/N) is shown at Vout=1V. See specs for details. otherwise noted. Output capacitors are 1 ?F ceramic and 10 ?F electrolytic in parallel. Input cap is 22 ?F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE Lx OK X 2-/T 16 - D12 P - C RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS Okami Non-isolated PoL exemption 7b?lead in solder) SIP Mount Pin Length Option Sequence/Tracking Blank = Standard pin length Blank = Not installed, delete pin 9 L6 = Pin length 0.138 inches (3.5mm)* 2 = Installed, add pin 9 *Special quantity order is required; samples available Trimmable Output Voltage Range with standard pin length only. D12 Models = 0.7525-5.5V On/Off Logic Maximum Rated Output P = Positive Logic Note: Current in Amps N = Negative Logic Some model number combinations may not be available. See website or contact your local Murata sales Input Voltage Range representative. D12 = 8.3-14V www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 2 of 16OKX T/10 & T/16-D12 Series Adjustable DOSA 10/16-Amp SIP DC/DC Converters Performance and Functional Speci? cations Short Circuit Duration Continuous, no damage See Note 1 (output shorted to ground) Prebias Startup Converter will start up if the external Input output voltage is less than Vset Input Voltage Range See Ordering Guide and Note 7. Dynamic Load Response 75 ?Sec max. to within ?2% of ? nal value Start-Up Voltage 7.75V (50-100% load step, di/dt=2.5A/?Sec) Undervoltage Shutdown (see Note 15) 7.50V Environmental Overvoltage Shutdown None Operating Temperature Range (Ambient) Re? ected (Back) Ripple Current (Note 2) 25 mA pk-pk See derating curves -40 to +85 deg. C. with derating (Note 9) Internal Input Filter Type Capacitive Operating PC Board Temperature -40 to +100 deg. Celsius max., Recommended External Fuse 15A no derating (12) Reverse Polarity Protection N/A. See fuse information Storage Temperature Range -55 to +125 deg. C. Input Current: Thermal Protection/Shutdown +130 deg. Celsius Full Load Conditions See Ordering Guide Relative Humidity to 85%RH/+85 deg. C., non-condensing 2 Inrush Transient 0.4 A Sec. Shutdown Mode (Off, UV, OT) 5 mA Physical Output in Short Circuit 100 mA Outline Dimensions See Mechanical Speci? cations No Load 80 mA Weight 0.2 ounces (5.6 grams) Low Line (Vin=Vmin, Vout=Vnom) 10.2 A. (OKX-T/16-D12), 6.34A (OKX-T/10-D12) Electromagnetic Interference Designed to meet FCC part 15, class B, EN55022 and CISPR22 class B conducted Remote On/Off Control (Note 5) and radiated (may need external ? lter) Negative Logic (?N? model suf? x) ON = Open pin or ground to +0.3V. max. OFF =+2.5V min. to + Vin (max) Restriction of Hazardous Substances RoHS-6 (does not claim EU RoHS Positive Logic (?P? model suf? x) ON = Open pin (internally pulled up) to exemption 7b?lead in solder) +Vin max. Absolute Maximum Ratings OFF = Ground pin to +0.3V. max. Current 1 mA max. Input Voltage (Continuous or transient) 0 V.to +15 Volts max. (D12 models) Tracking/Sequencing (OKX ?2? models) On/Off Control 0 V. min. to +Vin max. Slew Rate 2 Volts per millisecond, max. Input Reverse Polarity Protection See Fuse section Tracking accuracy, rising input Vout = +/-100 mV of Sequence In Output Current (Note 7) Current-limited. Devices can withstand a Tracking accuracy, falling input Vout = +/-200 mV of Sequence In sustained short circuit without damage. General and Safety The outputs are not intended to accept appreciable reverse current. Ef? ciency See Ordering Guide Storage Temperature -55 to +125 deg. C. Switching Frequency 300 KHz ? 25 kHz Lead Temperature See soldering speci? cations Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal (On/Off to Vout regulated) 8 mSec for Vout=nominal Isolation Notisolated Absolute maximums are stress ratings. Exposure of devices to greater than any of any Safety Designed to meet UL/cUL 60950-1, of these conditions may adversely affect long-term reliability. Proper operation under CSA-C22.2 No. 60950-1, IEC/EN 60950-1 conditions other than those listed in the Performance/Functional Speci? cations Table is not implied nor recommended. Calculated MTBF per Telcordia SR-232 (4a) 6.54 MHours (OKX2-T/16-D12P) Calculated MTBF per MIL-HDBK-217F (4b) 5.3 MHours (OKX2-T/16-D12P) Speci? cation Notes: Output (1) Specifications are typical at +25 deg.C, Vin=nominal (+12V. for D12 models), Vout=nominal (+5V for D12 models), full load, external caps and natural convection unless otherwise indicated. Extended tests at higher Output Voltage Range See Ordering Guide power must supply substantial forced airflow. Minimum Loading No minimum load All models are tested and specified with external 1 ?F paralleled with 10 ?F ceramic/tantalum output capacitors and a 22 ?F external input capacitor. All capacitors are low ESR types. These capacitors are Accuracy (50% load, untrimmed) ?2 % of Vnominal necessary to accommodate our test equipment and may not be required to achieve specified performance Voltage Output Range (Note 13) See Ordering Guide in your applications. However, Murata Power Solutions recommends installation of these capacitors. All models are stable and regulate within spec under no-load conditions. Overvoltage Protection (Note 16) None (2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Temperature Coef? cient ?0.02% per oC of Vout range Cin=2 x 100 ?F tantalum, Cbus=1000 ?F electrolytic, Lbus=1 ?H. Ripple/Noise (20 MHz bandwidth) See Ordering Guide and note 8 (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total Line/Load Regulation See Ordering Guide and note 10 RMS current over time does not exceed the Derating curve. Maximum Capacitive Loading (Note 14) (4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2, Cap-ESR=0.001 to 0.01 Ohms 1,000 ?F ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection. Cap-ESR >0.01 Ohms 5,000 ?F (4b) Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign, Tambient=+25 deg.C, full Current Limit Inception (Note 6) 30 Amps (OKX2-T/16-D12) output load, natural air convection. (98% of Vout setting, after warm up) 25 Amps (OKX2-T/10-D12) (5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to -Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed Short Circuit Mode +Vin. Short Circuit Current Output 2 A (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected Protection Method Hiccup autorecovery upon overload setting. removal. (Note 7) www.murata-ps.com/support MDC_OKX2_T10T16.B07 Page 3 of 16

Tariff Concession Code
Tariff Desc

9601650
8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5 W, being ANY of the following: (a) single in line package; (b) dual in line; (c) surface mount device Op. 01.07.1996 Dec.27.02.1996 - TC 9601650

Customer Comments  

Log in or register to post comments.

Customer Reviews

No reviews yet.