Product Information

NXJ2S2415MC-R7

Product Image X-ON

Module DC-DC 24VIN 1-OUT 15V 0.133A 2W 8-Pin SMD Module T/R
Manufacturer: Murata


Price (Ex GST)

From 7.1086

99 - Global Stock
Ships to you between
Fri. 11 Dec to Thu. 17 Dec
MOQ: 1 Multiples:
Pack Size :   1
Availability Price Quantity
99 - Global Stock


Ships to you between Fri. 11 Dec to Thu. 17 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 7.1086

Buy
149 - Global Stock


Ships to you between Thu. 10 Dec to Mon. 14 Dec
Calender

MOQ : 1
Multiples : 1
1 : $ 13.9543
5 : $ 10.0971
10 : $ 10.0286
25 : $ 9.9086
50 : $ 9.6686
135 : $ 9.1886
270 : $ 8.5886

Buy
99 - Global Stock


Ships to you between Fri. 11 Dec to Thu. 17 Dec
Calender

MOQ : 2
Multiples : 2
2 : $ 7.5284

Buy
         
Manufacturer
Murata
Product Category
Isolated DC/DC Converters
Category
Isolated Dc/Dc Converters
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image NXRT15WB473FA1B030
NTC Thermistors 0402 47Kohms 1%
Stock : 130
Stock Image NXRT15WF104FA1B030
Thermistors - NTC 0402 100Kohms 1%
Stock : 470
Stock Image NXRT15WB473FA3A016
Murata Electronics Thermistors - PTC
Stock : 4565
Stock Image NXRT15WF104FA1B040
Thermistors - NTC 0402 100Kohms 1%
Stock : 3193
Stock Image NXRT15WB473FA1B040
NTC (Negative Temperature Coefficient) Thermistors 47K OHM 1%
Stock : 1970
Stock Image NXRT15WF104FA1B020
NTC Thermistors 0402 100Kohms 1%
Stock : 1054
Stock Image NXRT15WB333JA1B040
NTC Thermistors 33K OHM 5%
Stock : 1275
Stock Image NXRT15WB473FA5B040
NTC (Negative Temperature Coefficient) Thermistors
Stock : 990
Stock Image NXRT15WB473FA5B030
NTC (Negative Temperature Coefficient) Thermistors 47K OHM 1%
Stock : 486
Stock Image NXRT15WF104FA1B010
NTC Thermistors 0402 100Kohms 1%
Stock : 1608
Image Description
Stock Image NXJ2S2405MC-R7
Module DC-DC 24VIN 1-OUT 5V 0.4A 2W 8-Pin SMD Module T/R
Stock : 686
Stock Image MGJ6D242005WMC-R7
Module DC-DC 24VIN 2-OUT 20V/-5V 0.24A/0.24A 6W 7-Pin SMD Module T/R
Stock : 25
Stock Image MGJ6D241510WMC-R7
Module DC-DC 24VIN 2-OUT 15V/-10V 0.24A/0.24A 6W 7-Pin SMD Module T/R
Stock : 22
Stock Image MGJ6D051505WMC-R7
Module DC-DC 5VIN 2-OUT 15V/-5V 0.3A/0.3A 6W 7-Pin SMD Module T/R
Stock : 24
Stock Image IRS-12/4.5-Q48N-C
Module DC-DC 48VIN 1-OUT 12V 4.5A 54W 8-Pin Tray
Stock : 48
Stock Image THM 15-4812
Isolated DC/DC Converters 36-75Vin 12V 1250mA 15W Iso Medical
Stock : 18
Stock Image IRQ-24/4.2-T110PVF-C
Isolated DC/DC Converters 24V/4.2A 57.6-160Vin Isolated 1/4Brick
Stock : 17

NXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 G? The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series Isolated 2W Single Output SM DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXJ2 series of DC-DC converters are all 100% production tested at 5.2kVDC for 1 second and have been quali?cation tested at 5.2kVDC for 1 minute. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The NXJ2 series is pending recognition by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the NXJ2 is not used as a safety barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier in excess of 1kV are sustainable. Long term reliability testing at these voltages continues. Please contact Murata for further information. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXJ2 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from speci?ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max, between input and output. UL 60950 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms. FUSING The NXJ2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as de?ned below. Input Voltage, 5V: 1A Input Voltage, 12V: 400mA Input Voltage, 24V: 250mA All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. www.murata-ps.com KDC_NXJ2.A02 Page 2 of 13NXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series Isolated 2W Single Output SM DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXJ2 series of DC-DC converters are all 100% production tested at 5.2kVDC for 1 second and have been quali?cation tested at 5.2kVDC for 1 minute. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The NXJ2 series is pending recognition by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the NXJ2 is not used as a safety barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier in excess of 1kV are sustainable. Long term reliability testing at these voltages continues. Please contact Murata for further information. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXJ2 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from speci?ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max, between input and output. UL 60950 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms. FUSING The NXJ2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as de?ned below. Input Voltage, 5V: 1A Input Voltage, 12V: 400mA Input Voltage, 24V: 250mA All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. www.murata-ps.com KDC_NXJ2.A02 Page 2 of 13NXJ2 Series Isolated 2W Single Output SM DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test con?guration. C1 1?F X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10?F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less C2 than 100m? at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450? resistor, carbon ?lm, ?1% tolerance R2 50? BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the speci?ed values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 R1 T1 R2 Y INPUT + + SUPPLY Input Output - - R LOAD RoHS COMPLIANCE AND MSL INFORMATION This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems. The NXJ2 series can be soldered in accordance with J-STD-020 and have a classi?cation temperature of 260?C and moisture sensitivity level 2. The termination ?nish on this product is Gold with plating thickness 0.12 microns. www.murata-ps.com KDC_NXJ2.A02 Page 3 of 13NXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series Isolated 2W Single Output SM DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXJ2 series of DC-DC converters are all 100% production tested at 5.2kVDC for 1 second and have been quali?cation tested at 5.2kVDC for 1 minute. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The NXJ2 series is pending recognition by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the NXJ2 is not used as a safety barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier in excess of 1kV are sustainable. Long term reliability testing at these voltages continues. Please contact Murata for further information. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXJ2 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from speci?ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max, between input and output. UL 60950 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms. FUSING The NXJ2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as de?ned below. Input Voltage, 5V: 1A Input Voltage, 12V: 400mA Input Voltage, 24V: 250mA All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. www.murata-ps.com KDC_NXJ2.A02 Page 2 of 13NXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series www.murata-ps.com Isolated 2W Single Output SM DC-DC Converters SELECTION GUIDE 2 MTTF 1 Order Code V V mA mA % % mVp-p % % kHz pF kHrs NXJ2S0505MC 5 5 550 400 7.5 10 50 110 68.5 72.5 140 2 2874 40967 FEATURES NXJ2S1212MC 12 12 215 167 7 9 30 70 72 75 120 2 1766 65080 ? Patents pending NXJ2S1215MC 12 15 215 133 8 10 25 60 75 77.5 110 2.2 1334 49049 ? Lower Pro?le NXJ2S2405MC 24 5 110 400 8 10 70 170 73 76.5 100 2.4 2026 33111 ? UL60950 Recognition pending NXJ2S2415MC 24 15 105 133 6.5 8 20 50 74.5 78.5 95 2.4 1232 44260 ? ANSI/AAMI ES60601-1, 2 MOOP, 1MOPP INPUT CHARACTERISTICS recognition pending Parameter Conditions Min. Typ. Max. Units ? 5.2kVDC Isolation ?Hi Pot Test? Continuous operation, 5V input types 4.5 5.0 5.5 Voltage range Continuous operation, 12V input types 10.8 12 13.2 V ? Substrate Embedded Transformer Continuous operation, 24V input types 21.6 24 26.4 ? Automated Manufacture Input re?ected ripple 5V input 15 mA p-p 3 current 12V & 24V input 5 ? Short Circuit Protection ? Halogen Free ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Production tested for 1 second 5200 Isolation voltage VDC Quali?cation tested for 1 minute 5200 PRODUCT OVERVIEW Resistance Viso= 1000VDC 10 GO The NXJ2 series is a new range of lower pro?le, OUTPUT CHARACTERISTICS fully automated manufacture surface mount Parameter Conditions Min. Typ. Max. Units DC-DC converters. The NXJ2 series automated Rated power TA=-40?C to 85?C 2.0 W manufacturing process with substrate Embedded Voltage set point accuracy See tolerance envelope Transformer, offers increased product reliability and repeatability of performance in a halogen 24V input types 1 1.1 Line regulation High VIN to low VIN %/% free, iLGA inspectable package. The NXJ2 series, All other input types 1.1 1.2 industry standard footprint is compatible with TEMPERATURE CHARACTERISTICS existing designs. Parameter Conditions Min. Typ. Max. Units The NXJ2 series has a MSL rating 2, and is com- Speci?cation All output types -40 85 patible with a peak re?ow solder temperature of Storage -50 125 260? C as per J-STD-020. ?C 5V input types 35 Product temperature rise above ambient 12V input types 30 24V input types 25 Cooling Free air convection ABSOLUTE MAXIMUM RATINGS Input voltage VIN, NXJ2S05 types 7V Input voltage VIN, NXJ2S12 types 15V Input voltage VIN, NXJ2S24 types 28V 1. Components are supplied in tape and reel packaging, please refer to package speci?cation section. Orderable part numbers are NXJ2SXXXXMC-R7 (135 pieces per reel), or NXJ2SXXXXMC-R13 (600 pieces per reel). 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model at TA=25?C with nominal input voltage at full load. 3. Please refer to short circuit application notes. All speci?cations typical at TA=25?C, nominal input voltage and rated output current unless otherwise speci?ed. For full details go to www.murata-ps.com/rohs www.murata-ps.com KDC_NXJ2.A02 Page 1 of 13 Nominal Input Voltage Output Voltage Rated Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Ef?ciency (Min) Ef?ciency (Typ) Switching Frequency (Typ) Isolation Capacitance MIL 217 TelecordiaNXJ2 Series Isolated 2W Single Output SM DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ?Hi Pot Test?, ?Flash Tested?, ?Withstand Voltage?, ?Proof Voltage?, ?Dielectric Withstand Voltage? & ?Isolation Test Voltage? are all terms that relate to the same thing, a test voltage, applied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NXJ2 series of DC-DC converters are all 100% production tested at 5.2kVDC for 1 second and have been quali?cation tested at 5.2kVDC for 1 minute. A question commonly asked is, ?What is the continuous voltage that can be applied across the part in normal operation?? The NXJ2 series is pending recognition by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the NXJ2 is not used as a safety barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier in excess of 1kV are sustainable. Long term reliability testing at these voltages continues. Please contact Murata for further information. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NXJ2 series has a PCB embedded isolated transformer, using FR4 as an insolation barrier between primary and secondary windings. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the FR4 insulation properties. Any material, including FR4 is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage should be reduced by 20% from speci?ed test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL ANSI/AAMI ES60601-1 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max, between input and output. UL 60950 The NXJ2 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms. FUSING The NXJ2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as de?ned below. Input Voltage, 5V: 1A Input Voltage, 12V: 400mA Input Voltage, 24V: 250mA All fuses should be UL recognized and rated to at least the maximum allowable DC input voltage. www.murata-ps.com KDC_NXJ2.A02 Page 2 of 13NXJ2 Series Isolated 2W Single Output SM DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test con?guration. C1 1?F X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10?F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less C2 than 100mO at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450O resistor, carbon ?lm, ?1% tolerance R2 50O BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the speci?ed values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 R1 T1 R2 Y INPUT + + SUPPLY Input Output - - R LOAD RoHS COMPLIANCE AND MSL INFORMATION This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems. The NXJ2 series can be soldered in accordance with J-STD-020 and have a classi?cation temperature of 260?C and moisture sensitivity level 2. The termination ?nish on this product is Gold with plating thickness 0.12 microns. www.murata-ps.com KDC_NXJ2.A02 Page 3 of 13

Tariff Concession Code
Tariff Desc

9601650
8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5 W, being ANY of the following:
(a) single in line package;
(b) dual in line;
(c) surface mount device
Op. 01.07.1996 Dec.27.02.1996 - TC 9601650