Product Information

DE1B3RA681KA4BP01F

Product Image X-ON

Ceramic Disc Capacitors 680pF ±10% 300VAC Through Hole,P=10mm RoHS
Manufacturer: Murata


Price (Ex GST)

From 0.0529

130 - Global Stock
Ships to you between
Wed. 09 Dec to Tue. 15 Dec
MOQ: 10 Multiples:
Pack Size :   10
Availability Price Quantity
30 - Global Stock


Ships to you between Wed. 09 Dec to Tue. 15 Dec
Calender

MOQ : 10
Multiples : 10
10 : $ 0.0864
100 : $ 0.0639
300 : $ 0.0598
1000 : $ 0.0555
5000 : $ 0.0538
10000 : $ 0.0529

Buy
         
Manufacturer
Murata
Product Category
Ceramic Disc Capacitors
RoHS - XON
Y Icon ROHS
Product
Safety Ceramic Disc Capacitors
Capacitance
680 pF
Tolerance
10 %
Voltage Rating AC
300 VAC
Dielectric
B
Lead Spacing
10 Mm
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+125 C
Diameter
8 mm
Packaging
Bulk
Series
De1
Termination Style
Radial
Type
Safety Disc Ceramic Capacitors For General Purpose
Brand
Murata Electronics
Capacitance - Nf
0.68 nF
Cnhts
8532249000
Hts Code
8532240060
Lead Diameter
0.6 Mm
Lead Style
Straight
Product Type
Safety Capacitors
Factory Pack Quantity :
250
Subcategory
Capacitors
Taric
8532240000
Category
Ceramic Disc Capacitors
Brand Category
Murata
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image DE1B3RB151KN4AR01F
Safety Capacitors 500VAC 150pF 10% Vert Crimp Taping
Stock : 365
Stock Image DE1B3RB101KN4AR01F
Safety Capacitors 500VAC 100pF 10% Vert Crimp Taping
Stock : 425
Stock Image DE1B3RB221KN4AR01F
Safety Capacitors 500VAC 220pF 10% Vert Crimp Taping
Stock : 604
Stock Image DE1B3RA681KN4AQ01F
Safety Capacitors 10x9 x6mm 500Vac 680pF
Stock : 1425
Stock Image DE1B3RA681KN4AP01F
Safety Capacitors 10x8x4mm 300Vac 680pF
Stock : 500
Stock Image DE1B3RA681KN4AN01F
Safety Capacitors 10x8x4mm 250Vac 680pF
Stock : 1983
Stock Image DE1B3RA681KJ4BP01F
Ceramic Disc Capacitors 680pF ±10% 300VAC Through Hole RoHS
Stock : 500
Stock Image DE1B3RB101KA4BR01F
Safety Capacitors 500VAC 100pF 10% Vert Crimp Long Ld
Stock : 455
Stock Image DE1B3RB151KJ4BR01F
Safety Capacitors 500VAC 150pF 10% Vert Crimp Short Ld
Stock : 500
Stock Image DE1B3RB221KA4BR01F
Safety Capacitors 500VAC 220pF 10% Vert Crimp Long Ld
Stock : 500
Image Description
Stock Image C410C102K5G5TA7200
Ceramic Disc Capacitors 1nF ±10% 50V Axial RoHS
Stock : 9030
Stock Image DE1B3RA681KJ4BP01F
Ceramic Disc Capacitors 680pF ±10% 300VAC Through Hole RoHS
Stock : 500
Stock Image DE1B3RA471KJ4BQ01F
Ceramic Disc Capacitors 470pF ±10% 500VAC Through Hole RoHS
Stock : 77
Stock Image DE1E3RA222MJ4BQ01F
Ceramic Disc Capacitors 2.2nF ±20% 500VAC Through Hole RoHS
Stock : 349
Stock Image DE1B3RA101KJ4BP01F
Ceramic Disc Capacitors 100pF ±10% 300VAC Through Hole RoHS
Stock : 455
Stock Image DE6E3KJ332MA3B
Ceramic Disc Capacitors 3.3nF ±20% 300VAC Through Hole RoHS
Stock : 309
Stock Image DE1B3RA221KJ4BN01F
Ceramic Disc Capacitors 220pF ±10% 250VAC Through Hole RoHS
Stock : 260
Stock Image DE2E3SA332MA3BT02F
Ceramic Disc Capacitors 3.3nF ±20% 250VAC Through Hole RoHS
Stock : 40
Stock Image CD90ZU2GA222MYVKA
Ceramic Disc Capacitors 2.2nF ±20% X1:440VAC Through Hole RoHS
Stock : 72465

Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference only CAUTION 1. OPERATING VOLTAGE When DC-rated capacitors are to be used in AC or ripple current circuits, be sure to maintain the Vp-p value of the applied voltage or the Vo-p which contains DC bias within the rated voltage range. When the voltage is started to apply to the circuit or it is stopped applying, the irregular voltage may be generated for a transit period because of resonance or switching. Be sure to use a capacitor within rated voltage containing these irregular voltage. Pulse Pulse Voltage DC Voltage DC+AC Voltage AC Voltage Voltage(1) Voltage(2) Positional Vo-p Vp-p Vo-p Vp-p Vp-p Measurement 2. OPERATING TEMPERATURE AND SELF-GENERATED HEAT Keep the surface temperature of a capacitor below the upper limit of its rated operating temperature range. Be sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current, pulse current or the like, it may have the self- generated heat due to dielectric-loss. Applied voltage should be the load such as self-generated heat is within 20 ?C on the condition of atmosphere temperature 25 ?C. When measuring, use a thermocouple of small thermal capacity-K of ?0.1mm and be in the condition where capacitor is not affected by radiant heat of other components and wind of surroundings. Excessive heat may lead to deterioration of the capacitor?s characteristics and reliability.(Never attempt to perform measurement with the cooling fan running. Otherwise, accurate measurement cannot be ensured.) 3. TEST CONDITION FOR WITHSTANDING VOLTAGE (1) TEST EQUIPMENT Test equipment for AC withstanding voltage should be used with the performance of the wave similar to 50/60 Hz sine wave. If the distorted sine wave or over load exceeding the specified voltage value is applied, the defective may be caused. (2) VOLTAGE APPLIED METHOD When the withstanding voltage is applied, capacitor?s lead or terminal should be firmly connected to the out-put of the withstanding voltage test equipment, and then the voltage should be raised from near zero to the test voltage. If the test voltage without the raise from near zero voltage would be applied directly to capacitor, test voltage should be applied with the *zero cross. At the end of the test time, the test voltage should be reduced to near zero, and then capacitor?s lead or terminal should be taken off the out-put of the withstanding voltage test equipment. If the test voltage without the raise from near zero voltage would voltage sine wave be applied directly to capacitor, the surge voltage may arise, and therefore, the defective may be caused. 0V *ZERO CROSS is the point where voltage sine wave pass 0V. zero cross - See the right figure - 4. FAIL-SAFE When capacitor would be broken, failure may result in a short circuit. Be sure to provide an appropriate fail-safe function like a fuse on your product if failure would follow an electric shock, fire or fume. 5. VIBRATION AND IMPACT Do not expose a capacitor or its leads to excessive shock or vibration during use. EGD08E 1 / 16 Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference only CAUTION 1. OPERATING VOLTAGE When DC-rated capacitors are to be used in AC or ripple current circuits, be sure to maintain the Vp-p value of the applied voltage or the Vo-p which contains DC bias within the rated voltage range. When the voltage is started to apply to the circuit or it is stopped applying, the irregular voltage may be generated for a transit period because of resonance or switching. Be sure to use a capacitor within rated voltage containing these irregular voltage. Pulse Pulse Voltage DC Voltage DC+AC Voltage AC Voltage Voltage(1) Voltage(2) Positional Vo-p Vp-p Vo-p Vp-p Vp-p Measurement 2. OPERATING TEMPERATURE AND SELF-GENERATED HEAT Keep the surface temperature of a capacitor below the upper limit of its rated operating temperature range. Be sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current, pulse current or the like, it may have the self- generated heat due to dielectric-loss. Applied voltage should be the load such as self-generated heat is within 20 ?C on the condition of atmosphere temperature 25 ?C. When measuring, use a thermocouple of small thermal capacity-K of ?0.1mm and be in the condition where capacitor is not affected by radiant heat of other components and wind of surroundings. Excessive heat may lead to deterioration of the capacitor?s characteristics and reliability.(Never attempt to perform measurement with the cooling fan running. Otherwise, accurate measurement cannot be ensured.) 3. TEST CONDITION FOR WITHSTANDING VOLTAGE (1) TEST EQUIPMENT Test equipment for AC withstanding voltage should be used with the performance of the wave similar to 50/60 Hz sine wave. If the distorted sine wave or over load exceeding the specified voltage value is applied, the defective may be caused. (2) VOLTAGE APPLIED METHOD When the withstanding voltage is applied, capacitor?s lead or terminal should be firmly connected to the out-put of the withstanding voltage test equipment, and then the voltage should be raised from near zero to the test voltage. If the test voltage without the raise from near zero voltage would be applied directly to capacitor, test voltage should be applied with the *zero cross. At the end of the test time, the test voltage should be reduced to near zero, and then capacitor?s lead or terminal should be taken off the out-put of the withstanding voltage test equipment. If the test voltage without the raise from near zero voltage would voltage sine wave be applied directly to capacitor, the surge voltage may arise, and therefore, the defective may be caused. 0V *ZERO CROSS is the point where voltage sine wave pass 0V. zero cross - See the right figure - 4. FAIL-SAFE When capacitor would be broken, failure may result in a short circuit. Be sure to provide an appropriate fail-safe function like a fuse on your product if failure would follow an electric shock, fire or fume. 5. VIBRATION AND IMPACT Do not expose a capacitor or its leads to excessive shock or vibration during use. EGD08E 1 / 16 Reference only 6. SOLDERING When soldering this product to a PCB/PWB, do not exceed the solder heat resistance specification of the capacitor. Subjecting this product to excessive heating could melt the internal junction solder and may result in thermal shocks that can crack the ceramic element. When soldering capacitor with a soldering iron, it should be performed in following conditions. Temperature of iron-tip : 400 ?C max. Soldering iron wattage : 50W max. Soldering time : 3.5s max. 7. BONDING, RESIN MOLDING AND COATING In case of bonding, molding or coating this product, verify that these processes do not affect the quality of capacitor by testing the performance of the bonded, molded or coated product in the intended equipment. In case of the amount of applications, dryness / hardening conditions of adhesives and molding resins containing organic solvents (ethyl acetate, methyl ethyl ketone, toluene, etc.) are unsuitable, the outer coating resin of a capacitor is damaged by the organic solvents and it may result, worst case, in a short circuit. The variation in thickness of adhesive, molding resin or coating may cause a outer coating resin cracking and/or ceramic element cracking of a capacitor in a temperature cycling. 8. TREATMENT AFTER BONDING, RESIN MOLDING AND COATING When the outer coating is hot (over 100 ?) after soldering, it becomes soft and fragile. So please be careful not to give it mechanical stress. Failure to follow the above cautions may result, worst case, in a short circuit and cause fuming or partial dispersion when the product is used. 9. OPERATING AND STORAGE ENVIRONMENT The insulating coating of capacitors does not form a perfect seal; therefore, do not use or store capacitors in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. And avoid exposure to moisture. Before cleaning, bonding, or molding this product, verify that these processes do not affect product quality by testing the performance of a cleaned, bonded or molded product in the intended equipment. Store the capacitors where the temperature and relative humidity do not exceed -10 to 40 ?C and 15 to 85%. Use capacitors within 6 months after delivered. Check the solderability after 6 months or more. 10. LIMITATION OF APPLICATIONS Please contact us before using our products for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party?s life, body or property. 1. Aircraft equipment 2. Aerospace equipment 3. Undersea equipment 4. Power plant control equipment 5. Medical equipment 6. Transportation equipment (vehicles, trains, ships, etc.) 7. Traffic signal equipment 8. Disaster prevention / crime prevention equipment 9. Data-processing equipment exerting influence on public 10. Application of similar complexity and/or reliability requirements to the applications listed in the above. EGD08E 2 / 16 Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference only CAUTION 1. OPERATING VOLTAGE When DC-rated capacitors are to be used in AC or ripple current circuits, be sure to maintain the Vp-p value of the applied voltage or the Vo-p which contains DC bias within the rated voltage range. When the voltage is started to apply to the circuit or it is stopped applying, the irregular voltage may be generated for a transit period because of resonance or switching. Be sure to use a capacitor within rated voltage containing these irregular voltage. Pulse Pulse Voltage DC Voltage DC+AC Voltage AC Voltage Voltage(1) Voltage(2) Positional Vo-p Vp-p Vo-p Vp-p Vp-p Measurement 2. OPERATING TEMPERATURE AND SELF-GENERATED HEAT Keep the surface temperature of a capacitor below the upper limit of its rated operating temperature range. Be sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current, pulse current or the like, it may have the self- generated heat due to dielectric-loss. Applied voltage should be the load such as self-generated heat is within 20 ?C on the condition of atmosphere temperature 25 ?C. When measuring, use a thermocouple of small thermal capacity-K of ?0.1mm and be in the condition where capacitor is not affected by radiant heat of other components and wind of surroundings. Excessive heat may lead to deterioration of the capacitor?s characteristics and reliability.(Never attempt to perform measurement with the cooling fan running. Otherwise, accurate measurement cannot be ensured.) 3. TEST CONDITION FOR WITHSTANDING VOLTAGE (1) TEST EQUIPMENT Test equipment for AC withstanding voltage should be used with the performance of the wave similar to 50/60 Hz sine wave. If the distorted sine wave or over load exceeding the specified voltage value is applied, the defective may be caused. (2) VOLTAGE APPLIED METHOD When the withstanding voltage is applied, capacitor?s lead or terminal should be firmly connected to the out-put of the withstanding voltage test equipment, and then the voltage should be raised from near zero to the test voltage. If the test voltage without the raise from near zero voltage would be applied directly to capacitor, test voltage should be applied with the *zero cross. At the end of the test time, the test voltage should be reduced to near zero, and then capacitor?s lead or terminal should be taken off the out-put of the withstanding voltage test equipment. If the test voltage without the raise from near zero voltage would voltage sine wave be applied directly to capacitor, the surge voltage may arise, and therefore, the defective may be caused. 0V *ZERO CROSS is the point where voltage sine wave pass 0V. zero cross - See the right figure - 4. FAIL-SAFE When capacitor would be broken, failure may result in a short circuit. Be sure to provide an appropriate fail-safe function like a fuse on your product if failure would follow an electric shock, fire or fume. 5. VIBRATION AND IMPACT Do not expose a capacitor or its leads to excessive shock or vibration during use. EGD08E 1 / 16 Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference Specification Type RA Safety Standard Certified Lead Type Disc Ceramic Capacitors for General Purpose Product specifications in this catalog are as of Dec. 2017, and are subject to change or obsolescence without notice. Please consult the approval sheet before ordering.Please read rating and Cautions first. Reference only CAUTION 1. OPERATING VOLTAGE When DC-rated capacitors are to be used in AC or ripple current circuits, be sure to maintain the Vp-p value of the applied voltage or the Vo-p which contains DC bias within the rated voltage range. When the voltage is started to apply to the circuit or it is stopped applying, the irregular voltage may be generated for a transit period because of resonance or switching. Be sure to use a capacitor within rated voltage containing these irregular voltage. Pulse Pulse Voltage DC Voltage DC+AC Voltage AC Voltage Voltage(1) Voltage(2) Positional Vo-p Vp-p Vo-p Vp-p Vp-p Measurement 2. OPERATING TEMPERATURE AND SELF-GENERATED HEAT Keep the surface temperature of a capacitor below the upper limit of its rated operating temperature range. Be sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current, pulse current or the like, it may have the self- generated heat due to dielectric-loss. Applied voltage should be the load such as self-generated heat is within 20 ?C on the condition of atmosphere temperature 25 ?C. When measuring, use a thermocouple of small thermal capacity-K of ?0.1mm and be in the condition where capacitor is not affected by radiant heat of other components and wind of surroundings. Excessive heat may lead to deterioration of the capacitor?s characteristics and reliability.(Never attempt to perform measurement with the cooling fan running. Otherwise, accurate measurement cannot be ensured.) 3. TEST CONDITION FOR WITHSTANDING VOLTAGE (1) TEST EQUIPMENT Test equipment for AC withstanding voltage should be used with the performance of the wave similar to 50/60 Hz sine wave. If the distorted sine wave or over load exceeding the specified voltage value is applied, the defective may be caused. (2) VOLTAGE APPLIED METHOD When the withstanding voltage is applied, capacitor?s lead or terminal should be firmly connected to the out-put of the withstanding voltage test equipment, and then the voltage should be raised from near zero to the test voltage. If the test voltage without the raise from near zero voltage would be applied directly to capacitor, test voltage should be applied with the *zero cross. At the end of the test time, the test voltage should be reduced to near zero, and then capacitor?s lead or terminal should be taken off the out-put of the withstanding voltage test equipment. If the test voltage without the raise from near zero voltage would voltage sine wave be applied directly to capacitor, the surge voltage may arise, and therefore, the defective may be caused. 0V *ZERO CROSS is the point where voltage sine wave pass 0V. zero cross - See the right figure - 4. FAIL-SAFE When capacitor would be broken, failure may result in a short circuit. Be sure to provide an appropriate fail-safe function like a fuse on your product if failure would follow an electric shock, fire or fume. 5. VIBRATION AND IMPACT Do not expose a capacitor or its leads to excessive shock or vibration during use. EGD08E 1 / 16 Reference only 6. SOLDERING When soldering this product to a PCB/PWB, do not exceed the solder heat resistance specification of the capacitor. Subjecting this product to excessive heating could melt the internal junction solder and may result in thermal shocks that can crack the ceramic element. When soldering capacitor with a soldering iron, it should be performed in following conditions. Temperature of iron-tip : 400 ?C max. Soldering iron wattage : 50W max. Soldering time : 3.5s max. 7. BONDING, RESIN MOLDING AND COATING In case of bonding, molding or coating this product, verify that these processes do not affect the quality of capacitor by testing the performance of the bonded, molded or coated product in the intended equipment. In case of the amount of applications, dryness / hardening conditions of adhesives and molding resins containing organic solvents (ethyl acetate, methyl ethyl ketone, toluene, etc.) are unsuitable, the outer coating resin of a capacitor is damaged by the organic solvents and it may result, worst case, in a short circuit. The variation in thickness of adhesive, molding resin or coating may cause a outer coating resin cracking and/or ceramic element cracking of a capacitor in a temperature cycling. 8. TREATMENT AFTER BONDING, RESIN MOLDING AND COATING When the outer coating is hot (over 100 ?) after soldering, it becomes soft and fragile. So please be careful not to give it mechanical stress. Failure to follow the above cautions may result, worst case, in a short circuit and cause fuming or partial dispersion when the product is used. 9. OPERATING AND STORAGE ENVIRONMENT The insulating coating of capacitors does not form a perfect seal; therefore, do not use or store capacitors in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. And avoid exposure to moisture. Before cleaning, bonding, or molding this product, verify that these processes do not affect product quality by testing the performance of a cleaned, bonded or molded product in the intended equipment. Store the capacitors where the temperature and relative humidity do not exceed -10 to 40 ?C and 15 to 85%. Use capacitors within 6 months after delivered. Check the solderability after 6 months or more. 10. LIMITATION OF APPLICATIONS Please contact us before using our products for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party?s life, body or property. 1. Aircraft equipment 2. Aerospace equipment 3. Undersea equipment 4. Power plant control equipment 5. Medical equipment 6. Transportation equipment (vehicles, trains, ships, etc.) 7. Traffic signal equipment 8. Disaster prevention / crime prevention equipment 9. Data-processing equipment exerting influence on public 10. Application of similar complexity and/or reliability requirements to the applications listed in the above. EGD08E 2 / 16

Tariff Concession Code
Tariff Desc

Free
8532.24.00 43 no --Ceramic dielectric, multilayer Free

Customer Comments  

Log in or register to post comments.

Customer Reviews

No reviews yet.