GV2RT10 Schneider
Motor breaker; 9/11kW; 230÷690VAC; DIN; Short circ.release:400A Stock : 3
Motor breaker; 37kW; 230÷690VAC; DIN; Overcurrent release:56÷80A Stock : 0
Motor breaker; 3/4kW; 230÷690VAC; DIN; Overcurrent release:6÷10A Stock : 27
Motor Drives MAN-START 600VAC 14AMP IEC Stock : 2
Motor breaker; 7.5kW; 230÷690VAC; DIN; Short circ.release:400A Stock : 7
Motor Drives MAN-START 600VAC 40AMP IEC Stock : 7
Circuit Breakers MAN-START 600VAC 5AMP AUX CONTACTS Stock : 0
Motor Drives MAN-START ENCLOSURE SEALING KIT IEC Stock : 0
Motor Drives MAN-START 600VAC 5AMP AUX CONTACTS Stock : 0
Motor Drives MAN-START PADLOCK DEVICE IEC Stock : 0
Circuit Breakers MAN-START 600VAC 40AMP IEC Stock : 15
Auxiliary/signalling contacts; Auxiliary contacts: NO + NO Stock : 16
Auxiliary contacts; Auxiliary contacts: NO or NC; front Stock : 49
Auxiliary contacts; Auxiliary contacts: NO + NC; front Stock : 388
Auxiliary contacts; Auxiliary contacts: NO x2; front Stock : 21
Circuit Breakers MAN-START 575VAC IEC UNDERVOLTAGE TRIP Stock : 24
Motor breaker; 0.04kW; 230÷690VAC; DIN; Short circ.release:1.5A Stock : 0
Motor breaker; 0.09kW; 230÷690VAC; DIN; Short circ.release:5A Stock : 5
Motor breaker; 0.75kW; 230÷690VAC; DIN; Short circ.release:33.5A Stock : 46
Product data sheet GV2RT10 Characteristics TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 46.3 A, screw clamp terminals Product availability: Stock - Normally stocked in distribution facility Main Range TeSys Product name TeSys GV2 Device short name GV2RT Device application Motor Transformer Trip unit technology Thermal-magnetic Complementary Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Operating position Any position Motor power kW 1.1 kW at 220/230 V AC 50/60 Hz (motor protection high peak current) 2.2 kW at 400/415 V AC 50/60 Hz (motor protection high peak current) 2.2 kW at 440 V AC 50/60 Hz (motor protection high peak current) 3 kW at 440 V AC 50/60 Hz (motor protection high peak current) 3 kW at 500 V AC 50/60 Hz (motor protection high peak current) 4 kW at 690 V AC 50/60 Hz (motor protection high peak current) 1.6 kW at 230/240 V AC 50/60 Hz (transformer protection) 2 kW at 230/240 V AC 50/60 Hz (transformer protection) 2.5 kW at 400/415 V AC 50/60 Hz (transformer protection) 2.5 kW at 440 V AC 50/60 Hz (transformer protection) 4 kW at 440 V AC 50/60 Hz (transformer protection) 4 kW at 500 V AC 50/60 Hz (transformer protection) 4 kW at 690 V AC 50/60 Hz (transformer protection) 5 kW at 690 V AC 50/60 Hz (transformer protection) 6.3 kW at 690 V AC 50/60 Hz (transformer protection) Breaking capacity 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 Control type Toggle In rated current 6.3 A Thermal protection adjustment range 4...6.3 A Magnetic tripping current 138 A System Voltage AC 50/60 Hz conforming to IEC 60947-2 Ui rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 Ith conventional free air thermal current 6.3 A conforming to IEC 60947-4-1 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Aug 15, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Electrical durability 100000 cycles AC-3 at 440 V Operating rate 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) solid Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) flexible without cable end Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) flexible with cable end Tightening torque 15.04 lbf.in (1.7 N.m) on screw clamp terminals Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height 3.5 in (89 mm) Width 1.77 in (45 mm) Depth 3.09 in (78.5 mm) Environment Standards IEC 60947-1 NF C 63-650 NF C 63-120 VDE 0113 NF C 79-130 CSA C22.2 IEC 60947-4-1 VDE 0660 UL 508 IEC 60947-2 EN 60204 Product certifications CCC CSA EAC UL Protective treatment TH IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK04 Ambient air temperature for operation -4...140 F (-20...60 C) Ambient air temperature for storage -40...176 F (-40...80 C) Fire resistance 1760 F (960 C) conforming to IEC 60695-2-1 Operating altitude 6561.68 ft (2000 m) Ordering and shipping details Category 22367 - MANUAL STR PROTECTOR - GV2 Discount Schedule I11 GTIN 00785901051220 Nbr. of units in pkg. 1 Package weight(Lbs) 0.60999999999999999 Returnability Y Country of origin FR Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0631 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference contains SVHC above the threshold - Go to CaP for more details- Go to CaP for more details Product environmental profile Available Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov 2