GV2P01 Schneider
Motor Drives MAN-START 600VAC 0.40AMP IEC Stock : 10
Motor breaker; 0.37/0.55kW; 230÷690VAC; DIN; IP20; -20÷60°C Stock : 24
Motor breaker; 1.1kW; 230÷690VAC; DIN; Short circ.release:51A Stock : 96
Motor breaker; 2.2kW; 230÷690VAC; DIN; Short circ.release:78A Stock : 34
Motor breaker; 5.5kW; 230÷690VAC; DIN; Overcurrent release:9÷14A Stock : 17
Motor Drives MAN-START 600VAC 0.25AMP IEC Stock : 10
Motor Drives MAN-START 600VAC 0.63AMP IEC Stock : 14
Motor Drives MAN-START 600VAC 1AMP IEC Stock : 37
Motor breaker; 0.75kW; 230÷690VAC; DIN; Short circ.release:33.5A Stock : 15
Motor breaker; 3kW; 230÷690VAC; DIN; Overcurrent release:6÷10A Stock : 38
Motor breaker; 15kW; 230÷690VAC; DIN; Overcurrent release:24÷32A Stock : 11
Motor breaker; 2.2kW; 230÷690VAC; DIN; Short circ.release:138A Stock : 18
Motor breaker; 37kW; 230÷690VAC; DIN; Overcurrent release:56÷80A Stock : 0
Circuit Breakers MAN-START 600VAC 40AMP IEC Stock : 15
Auxiliary/signalling contacts; Auxiliary contacts: NO + NO Stock : 16
Chapter Circuit breakers Control and TeSys GV, GB Protection B6 Components Circuit breakers - TeSys GV, GB Type of product Range Pages Magnetic circuit breakers for motors Up to 15, 30 kW B6/2 TeSys GV Thermal magnetic circuit breakers for motors B6/4 Up to 15, 37 or 110 kW TeSys GV Add-on blocks, accessories, B6/10 for motor circuit breakers Thermal magnetic circuit breakers for control circuits, Solenoid valves B6/26 From 0.5 to 23 A or transformers TeSys GB, GV Technical Data for Designers B6/29 B6/1 TeSys Circuit breakersReferences TeSys protection components Magnetic motor circuit breakers GV2 LE TeSys GV Magnetic motor circuit breakers from 0.06 to 15 kW GV2 LE: control by rocker lever, connection by screw clamp terminals Standard power ratings of 3-phase motors Magnetic Tripping Use in Reference 50/60 Hz in category AC-3 protection current association rating Id 20 % with 400/415 V 500 V 690 V thermal (1) (1) (1) P Icu Ics P Icu Ics P Icu Ics overload relay kW kA kW kA kW kA A A g g 0.06 0.4 5 LR2 K0302 GV2LE03 g g 0.09 0.4 5 LR2 K0304 GV2LE03 g g g g 0.12 0.37 0.63 8 LR2 K0304 GV2LE04 GV2 LE10 g g 0.18 0.63 8 LR2 K0305 GV2LE04 g g 0.55 1 13 LR2 K0305 GV2LE05 g g 0.25 1 13 LR2 K0306 GV2LE05 g g 0.75 1 13 LR2 K0306 GV2LE05 g g g g 0.37 0.37 1 13 LR2 K0306 GV2LE05 g g g g g g 0.55 0.55 1.1 1.6 22.5 LR2 K0307 GV2LE06 g g 0.75 1.6 22.5 LR2 K0307 GV2LE06 g g g g 0.75 1.1 1.5 3 75 2.5 33.5 LR2 K0308 GV2LE07 g g 1.1 2.5 33.5 LR2 K0308 GV2LE07 g g g g 1.5 1.5 3 3 75 4 51 LR2 K0310 GV2LE08 g g 2.2 4 51 LR2 K0312 GV2LE08 g g 2.2 3 50 100 4 3 75 6.3 78 LR2 K0312 GV2LE10 g g 3 4 10 100 5.5 3 75 10 138 LR2 K0314 GV2LE14 g g 4 5.5 10 100 10 138 LR2 K0316 GV2LE14 7.5 3 75 10 138 LRD 14 GV2LE14 9 3 75 14 170 LRD 16 GV2LE16 5.5 15 50 7.5 6 75 11 3 75 14 170 LR2 K0321 GV2LE16 7.5 15 50 9 6 75 15 3 75 18 223 LRD 21 GV2LE20 9 15 40 11 4 75 18.5 3 75 25 327 LRD 22 GV2LE22 11 15 40 15 4 75 25 327 LRD 22 GV2LE22 15 10 50 18.5 4 75 22 3 75 32 416 LRD 32 GV2LE32 (1) As % of Icu. g) > 100 kA. Characteristics: Dimensions: Schemes: pages B6/30 and B6/31 pages B6/43 to B6/45 page B6/48 B6/2 DF526144.tif