Product Information

AY1-B0-24-615-121-KC

AY1-B0-24-615-121-KC electronic component of Carling

Datasheet
Circuit Breakers 15A 120VAC 50/60Hz Rcsd Pdl Act no Aux

Manufacturer: Carling
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 45.8684 ea
Line Total: USD 45.8684

6 - Global Stock
Ships to you between
Wed. 10 Apr to Fri. 12 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
4 - Global Stock


Ships to you between Wed. 10 Apr to Fri. 12 Apr

MOQ : 1
Multiples : 1
1 : USD 66.1469
5 : USD 57.8272
100 : USD 57.0665
250 : USD 56.1004
500 : USD 55.1344
1000 : USD 54.6997

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Product
Type
Current Rating
Voltage Rating AC
Voltage Rating DC
Number of Poles
Actuator Type
Minimum Operating Temperature
Maximum Operating Temperature
Illuminated
Height
Length
Operating Temperature Range
Termination Style
Voltage Rating
Width
Brand
Mounting Style
Product Type
Factory Pack Quantity :
Cnhts
Hts Code
Subcategory
Notes*
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
6GK5E-73 electronic component of Carling 6GK5E-73

Switch Toggle (ON) None OFF DPST Bat Lever Screw 15A 250VAC 559.27VA Panel Mount with Threads
Stock : 1

1SS-WMSP3-R1/2-M6GE electronic component of Carling 1SS-WMSP3-R1/2-M6GE

Switch Rocker ON OFF ON SPDT PC Pins Small Rocker 3A 250VAC 28VDC Bulk
Stock : 1

2GA721-D-4B-B electronic component of Carling 2GA721-D-4B-B

Switch Toggle ON None OFF SPST Lever Quick Conn 20A 277VAC 1491.4VA Panel Mount with Threads
Stock : 1

3SS-WSP9-M2-RE electronic component of Carling 3SS-WSP9-M2-RE

Switch Push Button OFF (ON) SPST Round Plunger 20VAC 20VDC 0.4VA Momentary Contact PC Pins Thru-Hole
Stock : 1

62111122-0-0-N electronic component of Carling 62111122-0-0-N

Rocker Switches ON-NONE-ON CRV RCKR
Stock : 1

62115919-0-0-N electronic component of Carling 62115919-0-0-N

Rocker Switches DPST ON-NONE-OFF
Stock : 1

2GM721-D-4B-B electronic component of Carling 2GM721-D-4B-B

Toggle Switches DPDT ON-OFF-ON
Stock : 1

2FB54-73/2 HEX electronic component of Carling 2FB54-73/2 HEX

Toggle Switches F-Series Toggle Switch
Stock : 1

2GM720-D-4B-B electronic component of Carling 2GM720-D-4B-B

Toggle Switches G-Series Toggle Switch
Stock : 1

6GG5M-73 electronic component of Carling 6GG5M-73

Toggle Switches
Stock : 0

Image Description
21215-00 electronic component of Eaton 21215-00

Circuit Breakers CIRCUIT BREAKER TYPE II 1
Stock : 275

4404.0009 electronic component of Schurter 4404.0009

Circuit Breakers 7A 0.25" QC Snap-in front
Stock : 215

0812050.ZXST electronic component of Littelfuse 0812050.ZXST

Circuit Breakers 50A
Stock : 1

Hot W51-A121B1-20 electronic component of TE Connectivity W51-A121B1-20

TE Connectivity P&B Circuit Breakers 20A RCKR ACT RED ILL
Stock : 1

1658-A21-00-P10-20A electronic component of ETA 1658-A21-00-P10-20A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

TR11-D-X-63-BB-2-N-10.0A electronic component of Altech TR11-D-X-63-BB-2-N-10.0A

Circuit Breakers TR11sup.prot.,wingD,bl.slid.w/
Stock : 1

1658-G21-00-S83-5A electronic component of ETA 1658-G21-00-S83-5A

Circuit Breakers Very cost effective design to meet international requirements. No exposed metal parts which are current-carrying except for terminals. R-type TO CBE to EN 60934. Units built to order. For requests under 500 pcs contact Customer Service for verificati
Stock : 1

ETIMAT 6 1P D10 electronic component of ETI Polam ETIMAT 6 1P D10

Circuit breaker; 230/400VAC; Inom: 10A; Poles: 1; DIN; Charact: D
Stock : 1

ETIMAT P10 1P B6 electronic component of ETI Polam ETIMAT P10 1P B6

Circuit breaker; 230/400VAC; Inom: 6A; Poles: 1; DIN; Charact: B
Stock : 0

GV4AE11 electronic component of Schneider GV4AE11

Circuit Breakers TeSys BV4/GV4 Aux/Alarm Contact
Stock : 0

NOW PART OF A-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part Compact and Versatile Design The A-Series hydraulic-magnetic circuit breakers offer precise operation in a compact size for both general purpose as well as full amp load applications. Visi Rocker and recessed paddle actuators are ideally suited for clean, front panel designs while the metal toggle configuration is ideal for harsh environments. The A-Series is available as a one to six pole configuration, rated up to 50 amps, 277VAC/80VDC and has a max IC of 7,500 amps. 1-6 50 277 80 7500A Poles Amps Max VAC Max VDC Max Max IC Typical Applications Marine Renewable Energy Welders Telecom Generators Military www.carlingtech.com 860.793.9281 sales carlingtech.comTech Specs Mechanical Electrical Endurance 10,000 ON-OFF operations 6 Maximum Voltage 277VAC 50/60 Hz, 80VDC per minute with rated Current & Voltage. Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, Trip Free All A-Series Circuit Breakers will 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, trip on overload, even when the 40.0, 50.0. Other ratings available actuator is forcibly held in the ON - consult ordering scheme. position. Standard Voltage Coils DC-6V, 12V AC-120V, Other ratings Trip Indication The operating actuator moves available, consult ordering positively to the OFF position scheme. when an overload causes the circuit breaker to trip. When Auxiliary Switch Rating SPDT 10.1 A - 250VAC, mid-trip handle is specified, the 1.0 A-65VDC/0.5 A - 80 VDC, handle moves to the mid position 0.1A - 125VAC (with gold contacts) on electrical trip of the circuit breaker. When mid-trip handle Insulation Resistance Minimum: 100 Megohms at 500 with alarm switch is specified, VDC the handle moves to the mid Dielectric Strength UL, CSA - 1500V 60 Hz for one position & the alarm switch minute between all electrically actuates when the circuit breaker isolated terminals. A-Series is electrically tripped rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from Physical hazardous voltage to operator accessible surfaces per EN 60950 Number of Poles 1 - 6 Poles (handle) and 1-3 poles and VDE 0805. (rocker) at 30 Amps or less.1 and 2 poles at 31 Amps thru 50 Amps. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Internal Circuit Config. Series, (with or without auxiliary Breaker. switch), Shunt and Relay with current or voltage trip coils, Dual RESISTANCE PER POLE VALUES RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals from Line to Load Terminals Coil, Switch Only with or without (Values Based on Series Trip Circuit Breaker)(Values Based on Series Trip Circuit Breaker) auxiliary switch. 1000 CURRENT TOLERANCE Weight Approximately 65 grams/pole. (AMPS) (%) (Approximately 2.32 ounces/pole) 100 0.10 - 5.0 15 Standard Colors Housing - Black Actuator- See 5.1 - 20.0 25 Ordering Scheme. 10 20.1 - 50.0 35 O H 1 Environmental M S Designed and tested in accordance with requirements of 0.1 specification MIL-PRF-55629 & MIL-STD-202 as follows: 60 Hz 1/2 Cycle Inrush Pulse Tolerance Shock Withstands 100 Gs, 6ms, sawtooth Time Delay Curves 42, 44 & 46 0.01 (50 Amps Max.) while carrying rated current per Method 213, Test Condition I. Time Delay Curves 22, 24 & 26 0.001 (50 Amps Max.) Instantaneous and ultra-short 0.01 1 10 100 0.1 curves tested 90% of rated AMPERE RATING current. CURRENT TOLERANCE Pulse Tolerance Curves (AMPS) (%) Time in Vibration Withstands 0.060 excursion from Milliseconds 0.100-5.060 Hz 1/2 Cycle15% Inrush Pulse Tolerance5.1-20.0 25% 10-55 Hz, and 10 Gs 55-500 Hz, at 20.1-50.0 35% Time Delay Curves 50 Hz 1/2 Cycle rated current per Method 204C, 42, 44 & 46 FIGURE 1 Inrush Pulse Tolerance (50 Amps Max.) Test Condition A. Instantaneous Time Delay Curves 22x 42, 44 & 46 (50 Amps Max.) and ultrashort curves tested at Time Delay Curves 22, 24 & 26 (50 Amps Max.) Time Delay Curves 90% of rated current. 10x 22, 24 & 26 (50 Amps Max.) Moisture Resistance Method 106D ten 24-hour cycles 10.0 20.0 5.0 + 25C to +65C, 80-98% RH.56 Time in Time in Milliseconds days +85C, 85% RH. Milliseconds Salt Spray Method 101, Condition A (90-95% 50 Hz 1/2 Cycle RH 5% NaCl Solution, 96 hrs). Inrush Pulse Tolerance Time Delay Curves 22x 42, 44 & 46 Thermal Shock Method 107D, Condition A (Five (50 Amps Max.) cycles -55C to +25C to +85C Time Delay Curves 10x 22, 24 & 26 (50 Amps Max.) to +25C). Operating Temperature -40 C to +85 C 5.0 10.0 20.0 02. *Manufacturer reserves the right to change product specification without prior notice. Time in Milliseconds Multiple of Multiple of Rated Current Rated Current Multiple of Multiple of Rated Current Rated Current

Tariff Desc

CIRCUIT BREAKERS, AC AND/OR DC, having ALL of the following:
(a) current rating NOT greater than 400 A;
(b) single OR multiple pole;
(c) operating voltage NOT greater than 1 000 V AC
Op. 30.06.11 Dec. date 26.09.11 - TC 1121463
CARLING
Carling Technologies
Carling Technologies Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted