Product Information

232MSS2

232MSS2 electronic component of B&B Electronics

Datasheet
B&B Electronics Interface Modules 4PORT MINI SMART SWITCH WPTC

Manufacturer: B&B Electronics
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 286.5818 ea
Line Total: USD 286.58

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Tue. 07 May to Thu. 09 May

MOQ : 1
Multiples : 1

Stock Image

232MSS2
B&B Electronics

1 : USD 295.9778

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Type
Number of Channels / Ports
Maximum Data Rate
Operating Supply Voltage
Interface Type
Description/Function
Packaging
Dimensions
Operating Supply Current
Brand
Cnhts
Hts Code
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
808-38221 electronic component of B&B Electronics 808-38221

Fibre Optic Transmitters, Receivers, Transceivers IE-SFP/1250-ED SSLX-SM1310-SC
Stock : 2

855-10619 electronic component of B&B Electronics 855-10619

B&B Electronics Ethernet Modules MiniMc TP-TXSFP requires 155 Module
Stock : 0

ABDN-ER-DP551 electronic component of B&B Electronics ABDN-ER-DP551

WiFi / 802.11 Modules WiFi Ethernet Bridge Dual Band Enterprise
Stock : 0

ESWGP506-2SFP-T electronic component of B&B Electronics ESWGP506-2SFP-T

Ethernet Modules 4-Port Managed Gigabit PoE+ 2SFP
Stock : 0

485USB9F-4W-LS electronic component of B&B Electronics 485USB9F-4W-LS

B&B Electronics Interface Modules USB TO RS485 MINI CONVERTER
Stock : 1

4WSD25OTB electronic component of B&B Electronics 4WSD25OTB

B&B Electronics Interface Modules ISOLATED INLINE 485 CONV, 25 PIN VERSION
Stock : 0

C5UMB7FBG electronic component of B&B Electronics C5UMB7FBG

Ethernet Cables / Networking Cables CATEGORY 5E 7FT GREY
Stock : 2

808-38222 electronic component of B&B Electronics 808-38222

Fibre Optic Transmitters, Receivers, Transceivers IE-SFP/1250-ED SSLX-SM1550-SC
Stock : 2

EIRP610-2SFP-T electronic component of B&B Electronics EIRP610-2SFP-T

B&B Electronics Ethernet Modules INDUSTRIAL GB SWITCH 8 CU, 2 SFP)
Stock : 0

808-38200 electronic component of B&B Electronics 808-38200

Fibre Optic Transmitters, Receivers, Transceivers IE-SFP/1250-ED SM1310-LC
Stock : 2

Image Description
CYG2030 electronic component of IXYS CYG2030

Interface Modules Cybergate DAA Module
Stock : 1

MPCI-IBD192 electronic component of Ibase MPCI-IBD192

Interface Modules mPCIe,2*GLAN card,IBLD170 RJ45 w/Cable kit,2*Screws (RoHS)
Stock : 1

VAB-600-D electronic component of VIA VAB-600-D

Expansion board; LVDS x2,pin header; Works with: VAB-600
Stock : 1

MOTG-AC2 electronic component of 4D Systems MOTG-AC2

Interface Modules 2-slot MOTG for Gen4 Diablo
Stock : 1

WIZ145SR electronic component of Wiznet WIZ145SR

Interface Modules PIN HDR TYPE SERIAL-ENET MOD
Stock : 1

RS485-RS232 electronic component of Littelfuse RS485-RS232

Interface Modules RS-485:RS-232CONV.W/ CABLE&
Stock : 1

88980114 electronic component of Crouzet 88980114

Interface Modules Memory Interface for Controllers, Compatible With em4 And Millenium EVO Families
Stock : 1

PCE-3B06-00A1E electronic component of Advantech PCE-3B06-00A1E

Interface Modules 6-Slot PICMG1.3 BP,1 CPU Card, 1 PCIe x16, 4 PCIe x1,RoHS for IPC-6806S/IPC-3026
Stock : 0

PCA-6106P3-0D2E electronic component of Advantech PCA-6106P3-0D2E

Interface Modules 6-Slot Backplane (2 ISA, 2 PCI, 1 PICMG/PCI, 1 PICMG) Rev C. for IPC-6606, IPC-6006 and IPC-6806
Stock : 5

B-XC-232 electronic component of Advantech B-XC-232

Interface Modules B-XC-232-5
Stock : 1

232MSS2-0812ds -1/3 2003 by B&B Electronics. All rights reserved. Model 232MSS2 RS-232 Four-Port Mini Smart Switch/Port Combiner Description The RS-232 Four Port Mini Smart Switch/Port Combiner, Model 232MSS2, allows one RS-232 host device to connect to as many as four RS-232 devices. The 232MSS2 can function as a software and/or hardware controlled switch. As a software controlled switch, referred to as smart switch mode, the device connected to the master port of the 232MSS2 has control over which one of the four ports it is connected to. As a hardware controlled switch, referred to as port combiner mode, the handshake lines of the devices connected to the four ports are used to gain access to the master port. More details of smart switch and port combiner modes are covered later in this datasheet. There are four LED's on the 232MSS2 to indicate which port is connected to the master port. The master port has a DB-25S female connector and the slave ports have DB-9S female connectors. The master port can be configured as a DTE or DCE port by an internal switch setting (See Table 1). If the master port is configured as a DTE port, the four slave ports will become DCE ports. The 232MSS2 supports the following signals: TD, RD, RTS, and CTS. Handshake lines DSR and DTR are connected together and are not passed through to the master port. There is no delay through the device and data is not buffered. The 232MSS2 will work with baud rates from 1200 to 115,200 bps; 7 or 8 data bits; even, odd or no parity; and 1 or 2 stop bits (7,N, 1 is not allowed). The communication format is set via dipswitch 1 (SW1 -- See Table 1). NOTE: The data format and rates mentioned are used to switch the 232MSS2. Communication between the devices can use any format or data rate. Operation Smart Switch Mode The switch can be controlled in two different ways. The first way is referred to as smart switch mode. In this mode, the switch is controlled by sending a programmable three-character preamble code to theMaste port of the 232MSS2. The first character of the preamble code must be the ASCII Escape character (decimal 27). The second character is user programmable by setting Dipswitch 2 (SW2 -- See Table 2). The third character should be the ASCII upper case letters A, B, C, or D to select the appropriate port. The third character can also be the ASCII EOT (decimal 4) character, which will turn off all the ports. Example: To select port A, send the ASCII ESC character, the programmable character and the A character. When the 232MSS2 receives this code the master port will be connected directly to port A. Port Combiner Mode The other way to control the switch is referred to as port combiner mode. In port combiner mode, a slave port can gain access to the master port by asserting a handshake line (CTS for DTE slave ports, RTS for DCE slave ports). If a slave port asserts its handshake line and no other slave ports have their handshake line asserted, the master port will then be connected directly to the slave port with the asserted handshake line. Once a slave port is connected to the master port, the connection will remain until the slave disasserts its handshake line. If multiple slave ports have their handshake lines asserted, access will be granted on a first come-first serve basis. If none of the slave ports have their handshake line asserted, the switch can be controlled using the preamble codes. Example: (Initial conditions--no slave ports with handshake lines asserted) In chronological order, Port C asserts its handshake line, Port A asserts its handshake line, Port D asserts its handshake line and then Port C disasserts its handshake line. When Port C asserts its handshake line, a connection will be made between the master port and Port C. When Port C disasserts its handshake line, Port C will disconnected and Port A will be connected to the master port. When Port A disasserts its handshake, Port A will be disconnected and Port D will be connected to the master port. www.bb-elec.com orders@bb-elec.com support@bb-elec.com International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445 PRODUCT INFORMATION B&B ELECTRONICS 232MSS2-0812ds -2/3 2003 by B&B Electronics. All rights reserved. Timer Features Table 1 - Communication & Port Setup The 232MSS2 has an enhanced mode, which offers special timer features. The timer features can be used to prevent slave Dipswitch SW1 devices from receiving preamble commands, inadvertent Setting 1 2 3 4 5 6 7 8 switching from binary/graphic file transfers, and inactive slave 0 0 0 X X X X X 1200 Baud devices from holding control of the master port. The timer has 1 0 0 X X X X X 2400 Baud two different modes: an inactivity mode and an inadvertent 0 1 0 X X X X X 4800 Baud switch mode. When in inactivity mode, the 232MSS2 will 1 1 0 X X X X X 9600 Baud* monitor the data lines. If there is no activity for the specified 0 0 1 X X X X X 19.2K Baud time, the selected slave port will be disconnected from the 1 0 1 X X X X X 38.4K Baud master port. When in inadvertent switch mode, the 232MSS2 0 1 1 X X X X X 57.6K Baud will ignore switching commands for the specified time. After 1 1 1 X X X X X 115.2K Baud this time has expired, the selected slave port will be X X X 0 X X X X Enhanced Disabled * disconnected from the master port. X X X 1 X X X X Enhanced Enable Timer functions are enabled via a dipswitch setting and X X X X 0 X X X 8 Data Bits * through software commands. Software commands follow the X X X X 1 X X X 7 Data Bits same format as preamble codes used for switching. Two X X X X X 0 X X Parity Disabled * commands are used to set the timer functions: Set Timer Mode X X X X X 1 X X Parity Enabled and Set Timer Value. These commands require an additional X X X X X X 0 X Smart Switch Mode* byte for data. The Set Timer Value command requires the third X X X X X X 1 X Port Combiner Mode byte to be an ASCII T character. The data byte (fourth byte) X X X X X X X 0 DCE master port * must be a value between ASCII 0 and ASCII 9. A value of X X X X X X X 1 DTE master port 0 is used to disable the timer. Refer to Table 3 for timer 0 = OFF 1 = ON X = DON'T CARE values. *Factory defaults The Set Timer Mode command requires the third byte to be an ASCII M. If the Table 2 data byte (fourth byte) is an ASCII 0 (default), the timer will be setup as an Programmable Character Setting inactivity timer. When the timer is configured as an inactivity timer, the 232MSS2 Dipswitch SW2* Weight will monitor the data lines (TD & RD) for data. If there is no activity for the 1 1 specified timer value, the slave port that is connected to the master port will be 2 2 disconnected. In smart switch mode, the inactivity timer can be used to prevent 3 4 the preamble codes from being received by the slave devices. In port combiner 4 8 mode, the inactivity timer can be used to prevent devices from tying up the master 5 16 port. For example (port combiner mode): All the slave ports have their handshake 6 32 lines asserted. The device on Port C has its handshake line asserted and is 7 64 currently connected to the master port, but has not been transmitting or receiving 8 128 data. When the inactivity timer expires, Port C will be disconnected and the next *Factory Default --ASCII STX character slave port will then be connected to the master port (following the first come-first (decimal 2), SW2 position is only one ON. serve rule). Port C will then be placed at the end of the line. If the data byte of the Set Timer Mode command is an ASCII 1, the timer will be Table 3 - Timer Values set up to ignore switching commands. When the timer is configured in this mode, the 232MSS2 will not accept any switching commands (A, B, C, D, or Data Byte Value EOT) for the specified timer value. After the timer has expired the slave port that 0 timer disabled is connected to the master port will be disconnected. This feature is useful to 1 10ms prevent inadvertent switching during binary/graphic type file transfers. For 2 25ms example (smart switch mode): the timer is configured to ignore switching 3 100ms commands for 5 seconds. The select Port D command is sent to the 232MSS2. 4 500ms Once Port D is connected a file of unknown data type (so file may or may not 5 1 s contain a switching command sequence) is to be transferred through the 6 5 s 232MSS2. For a period of 5 seconds after Port D is connected, no switching commands will be accepted. As long as the file transfer takes less than 5 7 30 s seconds, there is no chance the 232MSS2 will inadvertently switch ports. 8 1 min. 9 5 min. www.bb-elec.com orders@bb-elec.com support@bb-elec.com International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445 PRODUCT INFORMATION B&B ELECTRONICS

Tariff Desc

8517.62.00 51 No Modems, of a type using digital to analogue modulation and analogue to digital demodulation, being goods of a kind having operational transmission speeds of 300 bits/second or greater
B B Battery
B&B Electronics
B&B Electronics (Quatech)
B&B SmartWorx, Inc.
B&K Precision
B+B Thermo-Technik

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted